Aqua Systems Eradicator Gen II Owner'S Manual Download Page 10

© 2019  New Aqua LLC dba Aqua Systems  • 114 Vista Park Way • Avon IN 46123

10

Eradicator Gen II O

3

Owners Manual Supplement

Ozone Specific  Information

Start Up

Plug the power supply into the receptacle. Refer to the main Eradicator manual for the instructions

for the start up procedure.

The programming for the O

is already done for Eradicator O

3

 systems, so no further action is 

needed beyond the normal start up procedure.

Once set up is complete, start the Eradicator in a manual regeneration and let it complete the

regeneration.

 The Eradicator with Ozone should only be installed, serviced, and programming accessed

 by qualified technicians.

It is highly recommended to have an annual inspection and maintenance on the Eradicator system

to keep it operating at optimum performance.

If any service or maintenance is required, contact your authorized dealer for this service.

Gen II O

3

 with Ozone

If the Eradicator O

3

 is installed in any damp or humid area, it is highly recommended to

to install the optional Air Dryer kit to the system to dry the air entering the O

3

 generator. 

This allows the generator to produce the optimum quantity and quality of ozone to enhance 

the Eradicator's performance and reduces required maintenance on the ozone producing 

components. The optional dryer mounts on the left backside of the valve controller.

Simply contact your authorized Eradicator dealer to obtain and install the dryer kit.

Note:

Summary of Contents for Eradicator Gen II

Page 1: ...3 with EOG II Owners Guide Owners Manual Supplement 7785 East US Hwy 36 Avon IN 46123 317 272 3000 800 447 5582 2019 New Aqua LLC Gen II TM CLOCK REGEN 1200 NEXT GAL GALLONS REMAINING CLOCK REGEN 1200...

Page 2: ...added oxygen The unique low voltage ozone generator has been designed to fit externally on the SmartChoice Eradicator control valve in which both are operated by a single low voltage power supply This...

Page 3: ...Eradicator Gen II O3 Owners Manual Supplement Ozone Specific Information Table of Contents Introduction 2 Eradicator with External Ozone Overview 4 5 External Ozone Installation 6 8 9 Ozone Resistant...

Page 4: ...ts job inside the filtration system it converts back to Oxygen O2 leaving the effluent water from the filter refreshingly oxygenated The ozone is generated from the auxiliary circuit board that is mou...

Page 5: ...en II EOG II Wire Harness Note The O3 components should only be inspected and serviced by a qualified service technician Gen II O3 with Ozone Side View with External Ozone When the control stops in th...

Page 6: ...f the valve body Then snug the clamp screw to secure the EOG II to the control valve Note The O3 components should only be inspected and serviced by a qualified service technician Power Supply Transfo...

Page 7: ...k tubing figure b from the EOG II into the push connect elbow figure a Be sure the tubing has fully seated If the tubing needs to be removed from the elbow press the locking collar figure c flush with...

Page 8: ...ft the board out Next remove the drive bracket by gently lifting the two tabs securing the the bracket and tilt it forward from the tabs The lower edge of the drive bracket has two notches that rest o...

Page 9: ...gh about 10 of the harness Then make sure the wire is fully seated in the strain relief slot Reinstall the drive bracket step 2 and the circuit board step 1 in the reverse order of removal Connect the...

Page 10: ...ed by qualified technicians It is highly recommended to have an annual inspection and maintenance on the Eradicator system to keep it operating at optimum performance If any service or maintenance is...

Page 11: ...ua LLC dba Aqua Systems 114 Vista Parkway Avon IN 46123 11 Eradicator Gen II O3 Owners Manual Supplement Ozone Specific Information Gen II O3 with Ozone Periodic Maintenance Log Date Service Performed...

Page 12: ...Revision 2 1 12 2019...

Reviews: