OPERATING INSTRUCTIONS 

To operate your spa you use your main control panel (keypad).

  – it features 4 

buttons (Pump, Blower, Light, Up/Down) and an LCD screen, which displays 
information on the status of the system, such as the water temperature or error 
messages.

 

Keypad TSC­9 

Key to Display Panel Icons and Buttons 

Button /icon 

Blinking 

On

 

Pump  active 

Blower active 

display shows desired 

temperature 

Heater not active, but water is 
heated to desired temperature. 

Heater active 

Light on (high intensity) 

Filter function suspended 

Filter function active 

Aqua Spa Owner´s Manual, page 11

 

MAIN FUNCTIONS

 

This section describes the most commonly used functions during the operation of the 
controller. 

Typically, each function is managed by a specific button, however sometimes the same 
button can be used to control more than one function (depending on the version of the 
firmware installed). 
The table below summarises the functions assigned to each button.

 

Button 

Function

 

Pump

 

Starts and stops jet pump.

 

Blower

 

Starts and stops the blower.

 

Light

 

Switches the light on and off

 

Up

 

Increase the values being set.

 

Down

 

Decrease the values being set.

 

Pump

­ if the pump is not stopped manually, it stops automatically after 20 minutes of 

continuous operation.

 

Light

­ if the light is not switched off manually, it switches off automatically after 20 

minutes.

 

Blower

 ­ if the blower is not stopped manually, it stops automatically after 20 minutes of 

continuous operation.

 

Filtration

– during operation, the filter icon is on steady; if one of the buttons, pump, 

blower or light is pressed during a purge cycle, the cycle is interrupted and will only 
resume 40 minutes after the last device stops.

 

Filtering function.

  When the filtration cycle is active, the filter icon will light up 

continuosly. The spa is programmed to run a filtration cycle once a day for 6 hours. 
During the filtration cycle the pump and blower  run in high speed mode for one minute 
to purge the plumbing, followed by the  pump at low speed for the rest of the cycle.  It is 
possible to program the duration of the filtration cycle. Hold the “light” button for 5 
seconds, the display shows the current duration value. Use the “Up/Down” key to adjust 
this value. Press again the “Light” key, the display shows the parameter D indicates the 
number of hours to delay the start of the filtration cycle, use the “ Up/Down” key to 
adjust the value. 
During the set up, if the user doesn’t press any key for 5 seconds, the system memorises 
the new setting, but it will take effect only at the next cycle. However, if the user exits the 
setting by pressing the “light” key again the new setting is memorised. 

If during the filter cycle the user presses any key, the cycle is suspended whilst the spa is 
being used. Once the spa has been inactive for 40 minutes the filtration cycle continues. 
When the Filtration cycle is suspended the filter icon LED will flash intermittently. 

Aqua Spa Owner´s Manual, page12

Summary of Contents for Cassaone

Page 1: ...at you will enjoy this spa for many years In order to receive the full benefit of your spa you need to understand how it functions We suggest than you take some time to carefully read this owner s man...

Page 2: ...after using your spa for your children s safety WARNING Risk of injury Never operate your spa if the suction fittings are broken or missing to prevent body and hair entrapment Never replace a suction...

Page 3: ...e your spa on a flat surface Wipe the interior of the spa with a damp cloth Fill the spa with water Never turn the spa on without water It will void your warranty if any damage occurs to the pumps hea...

Page 4: ...action Drain Valve Drains water from the spa Exterior Components Description Control panel Keypad gives you unrestricted access to all of the spa s functions Light illuminates the spa water at dark Ma...

Page 5: ...power cable should be connected to the main power supply The MICROSPA controller can be connected to power supply Single phase 230 V 50 60Hz 15 A All models must be permanently connected hard wired an...

Page 6: ...ot stopped manually it stops automatically after 20 minutes of continuous operation Filtration during operation the filter icon is on steady if one of the buttons pump blower or light is pressed durin...

Page 7: ...ARNING The current management feature should only be adjusted by a qualified spa technician Any problems and damages cause by unauthorised adjustment of the current management feature will invalidate...

Page 8: ...hell as it will damage the surface Use a dispenser or place the sanitizer tablets in the filter basket Test the spa water using water test strips Check and adjust chlorine sanitzer level recommended l...

Page 9: ...turn face left and right making sure they are free from any obstructions Changing the Water It is suggested that you change the water once every four months depending on the area and the amount of us...

Page 10: ...R TROUBLESHOOTING Symptom Possible Causes Solution Cloudy Water Dirty filter Clean filter use cleaner or degreaser High pH alkalinity Adjust pH using pH minus or pH plus Suspended particles Use clarif...