Aqua-Scope PREWIE02 User And Installation Manual Download Page 5

The t-shaped part of the device is exposed to drinking water and therefore subject to the European 
Drinking Water Directive. The certified used material is called CW509L, which is in the list of approved of 
materials of the German Environment Agency (UBA) in the version from May 14th, 2020 under section 
2.1.3.1.

Technical Data

Power Supply: External USB Power Plug 5 V/ 1A
Battery: Bobbin Cell C ER26500, Lithium-Thionyl Chloride
Processor: ESP32-WROOM_32E (Xtensa Dual Core 32 Bit, 240 MHz, 520 KB RAM)
Wireless Connection:

WIFI ESP Built-in 2.4 GHz 802.11 b/g/n, bitrate in ‘n’ mode up to 150Mbps
Lora: SX1261, EU868 MHz, SF 7-12, TX16 dBm, RX: - 147 dBm @ 300 bps, Class A

Pressure Sensor Head:

Range : 0 … 1000 kPa (10 bar)
Overload: 150 Percent of maximum pressure
Connection: G ¼ “ female
Communication: I2C
Precision:
Built-in High-Precision Temperature Sensor

Dimensions (Main): 91 mm x 91 mm x 30 mm
Weight (Main Device): 105 gr
Weight (Sensor Head): 140 gr
Protection: Main Device: IP 65, Sensor Head: IP 67
User Interface: 4 colored LED, single touchless button
Environmental Conditions:

Shipment and Storage: -65 °C … 125 °C
Operation: - 20 °C … 50 °C
Rel. Humidity: 0...90 %

Support and Contact

Should you encounter any problem, please give us the opportunity to address it before returning this 
product. Please check our website www.aqua-scope.com and particularly the support section for answers 
and help. You can also send a message to [email protected].

While the information in this manual has been compiled with great care, it may not be deemed an 
assurance of product characteristics. Aqua-Scope shall be liable only to the degree specified in the terms 
of sale and delivery. The reproduction and distribution of the documentation and software supplied with 
this product and the use of its contents is subject to written authorization from Aqua-Scope. We reserve 
the right to make any alterations that arise as the result of technical development.

Users and Installation Manual: Water Pressure Sensor (PREWIE02)

Copyright © 2022 Aqua-Scope Technologies, Sakala tn 7-2, 10141 Tallinn, Estonia, www.aqua-scope.com

Summary of Contents for PREWIE02

Page 1: ...stainless steel diaphragm and is therefore very precise The sensor can send an alarm message if freely definable threshold values are exceeded or notreached The sensor s polling frequency can be set...

Page 2: ...sor head into the side opening of the connector and fasten it by hand There is no need to make it super tide 7 Re Open the edge valve by turning the knob anti clockwise 8 Please check all three connec...

Page 3: ...in the Aqua Scope App or they are reported into the network when integrated into third party systems The device offers a low watermark and a high watermark threshold that can be defined using the mobi...

Page 4: ...e device will report its status every 20seconds and receive commands from the app Cloud In battery mode the device wakes up every hour only Hence every command such as open close of the valve or setti...

Page 5: ...ection Main Device IP 65 Sensor Head IP 67 User Interface 4 colored LED single touchless button Environmental Conditions Shipment and Storage 65 C 125 C Operation 20 C 50 C Rel Humidity 0 90 Support a...

Page 6: ...sel internetiaadressil www aqua scope com ce English Hereby Aqua Scope Technology O declares that the radio equipment type PREWIE02 is in compliance with Directive 2014 53 EU The full text of the EU d...

Page 7: ...y pod nast puj cym adre sem internetowym www aqua scope com ce Portugu s O a abaixo assinado a Aqua Scope Technology O declara que o presente tipo de equipamento de r dio PREWIE02 est em conformidade...

Page 8: ...he collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging health and well b...