13
ENGLISH
Replacing the Track
1.
Stand the cleaner on its side
(Figure 23).
Figure 23. Stand Cleaner on its Side
2.
Starting at one of the wheels, pull on the
inside of the track to separate the tire lip
from the wheel. Remove the track from
the cleaner.
3.
To install a new track, place the inside rib
of the track into the groove in the first
wheel (Figure 24).
4.
Stretch the track around the second
wheel (Figure 24). Push and position the
rib of the track so that the track is seated
properly in the groove of the wheel.
5.
Verify the rib of the track is positioned
properly within the groove of each of
the wheels. If necessary, turn the wheels
gently to seat track.
Figure 24. Stretch Track Around Wheels
Spare Parts
The complete spare parts list and exploded
view is available on the Aqua Products
website: AquaProducts.com
Contact your local maintenance provider to
perform diagnostic tests or repairs not shown in
general maintenance.
Troubleshooting
Using the Information LED
The Information LED
on the control unit
flashes in a specific sequence to indicate one of
three possible cleaner malfunctions.
LED Flashing
Solution
Single Flash
LED flashes once
with one second
interval
•
Unplug the floating cable from
the control unit and reconnect.
•
If the problem persists, contact
your local retailer to request
a diagnostic review or call
Technical Support.
Two Flashes
LED flashes twice
with one second
interval
•
Turn cleaner wheels to ensure
they are not jammed.
•
Check brushes for debris.
•
Start a new cleaning cycle.
•
If the problem persists, contact
your local retailer to request
a diagnostic review or call
Technical Support.
Three Flashes
LED flashes three
times with one
second interval
•
Clean the filter canister.
•
Check the pump axis for debris.
•
Check propellor for debris.
•
Start a new cleaning cycle.
•
If the problem persists, contact
your local retailer to request
a diagnostic review or call
Technical Support.