9
For example: When the water temperature in the aquarium is 20° C and you want to heat it up to
25° C, operate as follows: Hold the “Set” key for 5 seconds to enter into the “Setting” mode. The
“Set” LED starts flashing. Press the “+” or “-“key to adjust the set temperature to 25° C.
The compressor and the fan will start working after 15 seconds and the “Set” LED lights will be on
instead of flashing (standby state). The machine will start heating. When the water temperature
rises to 25° C, compressor and fan stop working. The “On” LED lights will be off and the machine
stops heating.
4.4. Fault mode
If there’s a fault when the machine is working, the water temperature display window will display
the corresponding fault code. The contents are shown below:
Code
Fault Code Fault Reason
Solution
1
E1
Temperature sensor open / short circuit or
exceeds the using scope.
Replace sensor or adjust the
using scope.
2
E2
Defrosting sensor open / short circuit or
exceeds the using scope.
Replace sensor or adjust the
using scope.
5. Installation
After unpacking the unit, please check if it is damaged during transportation. Please contact the
distributor if there’s any difference or enquiry.
10.
Please ask a professional technician to install the unit and provide a special socket for the
machine. Assure the power supply is in accordance with the machine.
11.
Install the product in ventilated surroundings without direct sunlight. Assure it is
convenient to install pipes and wiring.
12.
Please place the machine on an even and solid surface.
13.
The air cooling radiator has rear air inlet and front air outlet. Keep the rear panel of the
product 20 cm away from the wall to ensure air ventilation and product maintenance.
14.
Please filter sea water before filling it into the unit. Otherwise, it may damage titanium pipe
of the evaporator.
15.
Install a water pump of the right size and make sure that there is a max. pressure on the
heat exchanger of 0.2 bar (2 m water).
16.
If the machine won’t be used for a longer period, please cut off power supply of the unit.
17.
Periodically check and clean the condenser for assuring the performance of the unit
according to the working environment conditions.
18.
Please use soft pipe to install the inlet and outlet water pipe with reasonable fixing, thus to
avoid a damage of the water inlet and outlet due to vibration of the product.
19.
If it is installed indoors, please make sure that the exhaust air is directed outdoors.
6. Safety Precautions
5.
Please ask a professional technician to install the unit to avoid any problems with fire,
electronic shock, physical injury, leakage or damage of the product as a result of mistakes.
6.
Use power supply correctly, please connect the ground wire.
7.
If there’s a fault, stop the unit immediately and cut off power supply. Then consult the
distributor.
8.
Please don’t press the power switch with wet hand to avoid an electric shock.
5. Maintenance and/or repairs should be done exclusively either by a service engineer or by
the manufacturer.
9.
Please don’t insert hard objects into the unit. This may damage the heat exchanger.
10.
Assure that the water pump and pipes are installed correctly. Otherwise, the power of the
product may decrease.
11.
Place the unit on an even and solid surface, protecting it from falling down.
12.
Avoid installing the product in a public space. If it is required to install it in a public place,
assure to keep it far away from children. It is not allowed to install it in flammable and
explosive space.