Safety advices
!
•
The lighting must not be used under water.
•
In case of changing the fluorescent lamps, always disconnect the light from the
mains.
!
•
If the connecting cable is damaged, it may not be repaired. The light must be
replaced completely.
•
The light must not be opened.
!
•
When working on the aquarium, disconnect the lighting system from the mains.
•
Do not try to repair the lighting system. Please send it in for checking,
preferably with a list of defects.
•
Socket rings always have to be mounted and pulled tightly. Never run the light
without socket rings.
2.3. Unpacking
Check the lamp thoroughly for damage that might have incurred through transportation. In case of
any complaints, please contact your dealer directly.
2.4. Bulbs
The lighting system is being delivered without any lamps. We do recommend to use Aqua Medic’s
T5 fluorescent lamps
Ocean White
and
Ocean Blue
for saltwater aquaria.
Model
Fluorescent lamps
Fluorescent lamps’ length
sun cover
2 x 54 Watt+
Ocean White, 54 W
Ocean Blue, 54 W
115 cm
2.5. Lamp’s assembly / change of lamps
When changing the fluorescent lamp, first of all the socket rings have to be released and pushed
over the pipe. Now, the pipe can be taken out.
When assembling the new fluorescent lamp, first of all the socket rings have to be pushed on the
pipe. Then the lamp can be inserted.
Please make sure that the socket rings are mounted tightly on the pipe when mounting the lamp.
The lamps are only waterproof if the rings are mounted correctly. Also pay attention that the
sealing at the socket ring is mounted correctly.
Only turn on the light when the fluorescent lamp is mounted and the socket rings are fastened
tightly. Replace broken socket rings by new original ones by Aqua Medic.
2.6. Maintenance and Care
The service life of the T5 bulbs will be about 6,000 to 8,000 hours. This corresponds to about 1,5
years with a daily illumination time of 10 hours. It is recommended to exchange the bulbs before
expiration of this time interval since efficiency and colour composition change.
Clean the sun cover from time to time using a moistened cloth. Never use any additional cleaning
agents!