Aqua Guard DualFlo DF102STL Owner'S Manual Download Page 3

3

AquaGuard  |  DualFlo

 Installation

Installation Location

Locate pump as close to pool/spa as possible, preferably in a 

dry, well ventilated area away from direct sunlight. It should 

be on a hard, level surface. Give consideration to:
1. Drainage – away from pump.
2. Ventilation of pump motor.
3. Access for future servicing and winterizing.
4. Protection from the elements.
Pumps without strainer bodies are designed for flooded 

suction (all suction fittings and suction piping below water 

level) and will not self-prime. Consequently, the pump 

must be installed at an elevation that is below water level 

when pool or spa is filled; however, if suction line valves are 

installed, the pump may be closed for priming. Keep vertical 

distance to a minimum if you choose to mount pump above 

water level. 
Pumps with strainer bodies are self-priming but should be 

mounted as close to the water level as possible or below for 

ease in priming.

Vertical Water Discharge

DualFlo pumps come set for vertical discharge and can be 

changed to horizontal.

  

WARNING: Make sure the power has been cut off before 

performing the below actions.

1.  Open the clear cover and remove the clip located inside 

the strainer housing. Then detach the strainer housing 

from the rest of the pump unit.

2.  Unscrew and remove all the screws from the pump cover 

and remove the pump cover from the rest of the pump 

unit.

3.  Unscrew and remove the cap from the back of the motor, 

then unscrew the four (4) long bolts located on the  

“four-corners” of the motor.

4.  Using a screw driver, lock the middle Axis on the motor 

and turn the impeller (located on the other end of the 

motor) until the impeller is removed. Remove the pump 

housing from the motor.

5.  Separate the motor mounting plate from the pump 

housing and rotate the pump housing 90 degrees. 

The discharge pipe area will now be facing side ways/

horizontal. Reconnect the motor mounting plate to the 

pump housing.

6. Reverse instructions 4 to1 to reassemble the pump.

Electrical Data

Refer to information on motor nameplate for electrical 

service data. All motors should have fused disconnect 

switch or circuit breaker. Be sure wire size is sufficient for 

pump HP and distance from power source. Wiring should be 

done in accordance with applicable codes by a competent 

electrician. We recommend the installation of a ground fault 

circuit interrupter for maximum safety.

General Plumbing

FOR SOLVENT WELD CONNECTION - 

Rigid or flexible PVC 

pipe can be used. Pipe ends should be clean and free of any 

flash cause by the cutting operation. Be sure that the proper 

adhesive is used on the type of pipe specified.

  

NOTE: A primer will assure that adhesive joints are 

superior. Suregard P-3000 has a purple tracer to qualify in 

areas where codes specify a primer must be used.

  

CAUTION:

 

We recommend that you consider climatic 

conditions when applying adhesives. Certain atmospheric 

situations, such as high moisture content, make 

adhesive action of certain glues less effective. Check the 

manufacturer’s instructions.

FOR THREADED CONNECTIONS - 

Use only Teflon tape or 

equivalent on threaded plumbing connections. Other pipe 

compounds may damage threads. We do not recommend 

the use of silicone or petroleum based compounds. 

DO NOT OVER TIGHTEN – HAND TIGHTEN PLUS ½ TURN IS 

SUFFICIENT.

Pump Plumbing

Suction pipe should be as large or larger that discharge pipe. 

Avoid using suction pipe small that pump connection. 
Keep the piping as straight and short as possible, and of 

suitable size. Avoid connecting an elbow directly into the 

pump inlet (use a length of straight pipe to allow a proper 

entry for the water). Arrange horizontal runs to slope 

upward to the pump to prevent high spots that could form 

air pockets. Support the pipe independently so that it places 

no strain on the pump. Keep as much of the suction line 

as possible below the water level to reduce priming time. 

Install valves and unions in the pump suction and return 

lines to facilitate servicing. Valves are recommended for 

throttling maintenance if the system is installed below deck 

level. Suction valves are essential for priming all pumps 

without strainer bodies installed above water level. Pumps 

with strainer bodies are self-priming, nevertheless, we 

recommend the use of check valve in the suction pipe at 

or below the water level if the suction lift is more that five 

feet or if the dry suction is more that ten feet long. Keep the 

valve in the suction line fully open during operation.

Summary of Contents for DualFlo DF102STL

Page 1: ...installation is complete this manual must be given to the owner operator of this equipment This equipment must be installed and serviced by a qualified technician in accordance with all applicable cod...

Page 2: ...Failure to follow safety and operation instructions could result in violent separation of the pump housing cover or filter housing due to pressure in the system which could cause injury or death Suct...

Page 3: ...e wire size is sufficient for pump HP and distance from power source Wiring should be done in accordance with applicable codes by a competent electrician We recommend the installation of a ground faul...

Page 4: ...trainer bodies and locater above water close suction line valve and fill pump with water in order to prime For pumps with strainer bodies and located above water prime by removing strainer cover and f...

Page 5: ...e is 7 2 7 4 Pump Maintenance 1 Motors are self lubricating no lubrication required 2 Clean hair lint strainer if you have a strainer body pump 3 Visually inspect motor for blockage of air vents on mo...

Page 6: ...RE 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters NOISY PUMP AND MOTOR 1 Plugged basket in skimmer or hair in lint strainer 2 Worn motor bearings 3 Valve...

Page 7: ...52871 Impeller for DF102S and DF102STL 1 7b AGX272971 Impeller for DF152S and DF152STL 1 8 AGX280030 Seal Assembly 1 9 AGX252701 Pump Housing 1 10 AGX310400 Housing O Ring 1 11 AGX120160 Screw ST 5 5...

Page 8: ...ou specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise s...