 Safety Information

Important Safety Instructions

Be sure to read all instructions and warnings carefully. Refer 

to product data plate(s) for additional operating instruction 

and specifications. Safety precautions should always be 

followed, including the following:

  WARNING: DO NOT PERMIT CHILDREN TO USE  OR CLIMB 

ON THIS PRODUCT.

  WARNING: (For cord & plug connected units). Risk of 

Electrical Shock. Connect only to a grounding type 

receptacle protected by a ground-fault circuit-interrupter 

(GFCI). Contact a qualified electrician if you cannot verify 

that the receptacle is protected by a GFCI. Do not bury 

cord. Locate cord to minimize abuse from lawn mowers, 

hedge trimmers and other equipment. Replace a damaged 

cord immediately. Do not use an extension cord to connect 

unit to electrical supply; provide a properly located outlet.

  CAUTION:  (For pumps with a 25 ft. cord. This pump is for 

use with storable pools only. Do not use with permanently 

installed pools. A storable pool is constructed so that it 

may be readily disassembled for storage and reassembled 

to its original integrity. 

  CAUTION:  (For pumps with/without 3ft or 6ft. cord. This 

pump is for use with permanently installed pools and may 

also be used with hot tubs and spas if so marked. Do not 

use with storable pools. A permanently installed pool is 

constructed in or on the ground or in a building such that 

it cannot be readily disassembled for storage.

  WARNING:(For hot tub and spa pumps). Do not install 

within an outer enclosure or beneath the skirt of the hot 

tub or spa, unless so marked.

Hazardous Pressure and Separation

Pool and spa water circulation systems operate under 

hazardous pressure. Stand clear of circulation system 

equipment during startup. Failure to follow safety and 

operation instructions could result in violent separation of 

the pump housing, cover or filter housing due to pressure in 

the system, which could cause injury or death.

Suction Entrapment Hazards

Suction in suction outlets sumps/suction outlet covers 

which are, damaged, broken, cracked, missing, or unsecured 

(faulty) can cause severe injury/death due to the following 

entrapment hazards.

Hair Entrapment 

- hair can become entangled in suction 

outlet cover.

Limb Entrapment

 - a limb inserted into an opening of a 

suction outlet sump or suction outlet cover that is faulty can 

result in a mechanical bind or swelling of the limb.

Body Suction Entrapment

 - a negative pressure applied 

directly to the intestines through an unprotected suction 

outlet sump or suction outlet cover that is faulty can result 

in evisceration/disembowelment.

Mechanical

 

Entrapment

 - There is potential for jewelry, 

swimsuit, hair decorations, finger, toe or knuckle to be 

caught in an opening of a suction outlet cover resulting in 

mechanical entrapment.

  WARNING: Failure to remove pressure test plugs and/

or plugs used in winterization of the pool/spa from the 

suction outlets can result in an increase potential for 

suction entrapment as described above.

  WARNING: Failure to keep suction outlet components clear 

of debris can result in an increase potential for suction 

entrapment as described above

  WARNING: Suction outlet components have a finite life,  

the cover/grate should be inspected frequently and 

replaced at least every seven years or if found to be faulty.

  WARNING: Failure to remove pressure test plugs and/

or plugs used in winterization of the pool/spa from the 

suction outlets can result in an increase potential for 

suction entrapment as described above

Table of Contents

Safety Information   ............................................................................   2
Installation   ...........................................................................................   3
Initial Startup   ......................................................................................   4
Specifications   ......................................................................................   4
Maintenance   .......................................................................................   5

Trouble Shooting  ................................................................................   6
Winterizing   ..........................................................................................   6
DualFlo Parts Listing   ..........................................................................  7
Warranty   ................................................................................................  8

Summary of Contents for DualFlo DF102STL

Page 1: ...installation is complete this manual must be given to the owner operator of this equipment This equipment must be installed and serviced by a qualified technician in accordance with all applicable cod...

Page 2: ...Failure to follow safety and operation instructions could result in violent separation of the pump housing cover or filter housing due to pressure in the system which could cause injury or death Suct...

Page 3: ...e wire size is sufficient for pump HP and distance from power source Wiring should be done in accordance with applicable codes by a competent electrician We recommend the installation of a ground faul...

Page 4: ...trainer bodies and locater above water close suction line valve and fill pump with water in order to prime For pumps with strainer bodies and located above water prime by removing strainer cover and f...

Page 5: ...e is 7 2 7 4 Pump Maintenance 1 Motors are self lubricating no lubrication required 2 Clean hair lint strainer if you have a strainer body pump 3 Visually inspect motor for blockage of air vents on mo...

Page 6: ...RE 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters NOISY PUMP AND MOTOR 1 Plugged basket in skimmer or hair in lint strainer 2 Worn motor bearings 3 Valve...

Page 7: ...52871 Impeller for DF102S and DF102STL 1 7b AGX272971 Impeller for DF152S and DF152STL 1 8 AGX280030 Seal Assembly 1 9 AGX252701 Pump Housing 1 10 AGX310400 Housing O Ring 1 11 AGX120160 Screw ST 5 5...

Page 8: ...ou specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise s...

Reviews: