AQUA FORTE O-Plus Series Quick Start Manual Download Page 2

Do not let the pump run when not submerged in water. That may damage the pump. 

Always submerge the pump first, and then plug in the electrical outlet. At the begin-

ning, it probably can’t pump water, because there is air in the pump and the tube. Don’t 

worry about it. Please pull out and insert electrical outlet several times, it will work 

normally.

Automatic shut off if no water for 5 minutes (for 3500-10000), automatic shut off if no 

water for 2 minutes (for 13000-30000). Pull the plug out, and re-insert to resume work.

MAINTENANCE:

Unplug before cleaning. To clean the pump, remove the back cover, sealing cover and 

the impeller. Use a small brush or stream of water to remove any debris.

CAUTION!!: 

The pump shaft cannot be removed!

If the pump fails to operate, check the following:

• Check the outlet and try another outlet to ensure the pump is getting electrical power.

• NOTE: Always disconnect from electrical outlet before handling the pump.

• Check the pump outlet and tubing for kinks and obstructions. Algae may block them, 

please flush out the algae with a garden hose.

• Check the inlet to ensure it is not clogged with debris.

• Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not 

broken or jammed.

• Monthly maintenance will prolong your pump’s life.

• NOTE: Ensure that the electrical cord loops below the electrical outlet to form a “Drip 

Loop”. This will prevent water from running down the cord into the electrical outlet.

• When you find calcium/timescale deposits inside the motor house this implicates that 

the pumps becomes too warm during use! Calcium/lime scale expands above tempera-

tures of 55°C. With sufficient flow the pump is water cooled and cannot reach these 

temperatures. If, however, the head pressure is too big (too small pipe system, maxi-

mum pump head too big, etc) the flow will be reduced which causes insufficient cooling 

and by this, calcium deposits. In a worst case scenario the calcium/timescale layer will 

get so thick that it blocks the rotor and the motor will burn out. DAMAGE CAUSED 

BY CALCIUM/LIME SCALE IS NOT COVERED BY WARRANTY! You can remove 

calcium/lime scale deposits with commercial de-scaling products or vinegar

DISPOSAL:

Do not dispose this product as unsorted municipal waste. Collection

of such waste separately for special treatment is necessary.

AquaForte is a trademark  of Sibo BV, Doornhoek 3950, 5465TC, Veghel, Nederland

Email:[email protected] Website: www.aqua-forte.nl

REMARK:

For outdoor use. The pump is to be supplied through a residual current device (RCD) 

with a rated residual operating current not exceeding 30mA.

For all the models the maximum operation depth is 1,5m.

WARNING:

• Do not connect to any voltage other than that shown on the rating label of the pump.

• Do not pump flammable liquids. The appliance is only intended to be used in ponds/

aquarium. 

• The maximum operation depth is 1,5m.

• Do not use with water above 35℃.

• The supply cord cannot be replaced. If the cord is damaged the appliance should be 

scrapped.

• The pump is not intended for use by young children or infirm persons without super

-

vision.

• To protect against the risk of electrical shock, do not immerse the plug in water or 

other liquid. 

• This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised to ensure that they 

do not play with the appliance.

CAUTION!!:

Always disconnect from electrical outlet before cleaning, maintenance and handling the 

pump. Don’t operate without water.

Do not lift the pump by holding the power cord.

Do not use the pump in liquids having a temperature exceeding 35°C.   

Use the pump only in freshwater.

Please use the pump only when it is completely submerged in water.

Do not use the pump in swimming pools!!

INSTALLATION:

The pump is suited for both wet and dry applications. In a dry setup the pump must 

be under water level as it is not self-priming. For dry setup the external strainer house 

must be removed for the connection of the pipe fittings. Use without water (dry run-

ning) will result in irreparable damage. Under water, the pump must take in as clear as 

possible water. Never place

the pump in a muddy area or on sandy pond bottoms. Put the pump on a small pedes-

tal (e.g. a stone). Ignoring these instructions can cause

blockage of the strainer house around the pump. Heavily polluted water will cause 

problems for the rotor to run smooth and the pump

performance will decrease. In a worst case scenario the rotor will totally Block and the 

pump will burn out. Complete blockage of the pump

strainer house will prevent motor cooling which can cause burn outs.

PERFORMANCE:

A clogged or dirty intake screen will greatly reduce performance.

If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris 

contacting the intake. If less flow is desired, adjust the regulator on the sealing cover to 

restrict the flow.

Summary of Contents for O-Plus Series

Page 1: ...ages caused by improper handling or negligence on the part of the buyer All equipment must be sent postage paid Always remove plug from wall outlet first Open pump cover and remove pump Remove pump ho...

Page 2: ...nl REMARK For outdoor use The pump is to be supplied through a residual current device RCD with a rated residual operating current not exceeding 30mA For all the models the maximum operation depth is...

Page 3: ...kt sich auf einen evtl Austausch der defekten Teile Es bestehen keine Garantieanspr che bei unsachgem en Gebrauch der Pumpe oder bei einer Zweckentfremdung Gleiches gilt bei unzureichender oder keiner...

Page 4: ...e Stelle zur Recycling f r elektrische und elektronische Ger te entsorgt werden AquaForte is a trademark of Sibo BV Doornhoek 3950 5465TC Veghel Nederland Email info sibo nl Website www aqua forte nl...

Page 5: ...ntueel vervangen van defecte onderdelen Garan tie wordt beschouwd als nietig in geval van oneigenlijk gebruik en of schade veroorzaakt door onjuist gebruik of nalatigheid van de kant van de koper Voor...

Page 6: ...lektrisch circuit stopcontact waarop de pomp is aangesloten moet voorzien zijn van een lekstroombeveiliging van max 30mA Voor alle modellen is de maximale diepte waarop de pompen werkzaam zijn 1 5m WA...

Page 7: ...pi ces d fectueuses La garantie est consid r e comme nulle et non avenue en cas d utilisation mauvais escient et ou de dommage caus par une utilisa tion erron e ou par la n gligence dans le chef de l...

Page 8: ...max 30 mA Pour tous les mod les la profondeur maximale de fonctionnement des pompes est de 1 5 m AVERTISSEMENT Ne branchez pas la pompe sur une tension diff rente de celle mentionn e sur sa pla quette...