background image

2.)  Open air control valves to release any possible air

lock.

3.)  Make sure all suction and discharge lines are clear

and unobstructed and all valves are opened.

4.)  Check for air leaks in the suction line.

LOW WATER FLOW:

1.)  Check filter pressure gauge; filter may need

cleaning.

2.)  Check for clogged plumbing lines.

3.)  Check for worn or damaged impeller.

4.)  Check for low voltage.

WATER LEAKS

1.)  Check contamination or damage to shaft rotary

seal.  Replace if necessary.

2.)  Check compression fitting (union connectors);

make sure they are properly aligned and secured.

Hand tighten only.  Do not use tools.

3.)  Make sure O-ring is properly seated and not

damaged.

NOISES:

1.)  Check plumbing vibration-make sure lines are

adequately supported.

2.)  Check for cavitation, due to obstruction in or

undersized suction line.

INSTALLATION & OPERATING INSTRUCTIONS

Joint Stick or any other sealants formulated specifically

for plastics.

STARTING & PRIMING PUMP

Do not run unit dry.  

Always be certain that the pump

casing and/or trap is filled with water before starting the

unit.  Allow a reasonable amount of time for priming.  If

pump will not start, or will not prime, see trouble

shooting below.

MAINTENANCE

The trap basket should be inspected frequently and kept

clean.  To avoid damage to the basket, do not strike

when cleaning.  Inspect trap cover O-ring regularly and

replace as necessary.

Keep motor clean.  Insure that louvered openings are

free from debris and obstructions.  Over a period of time,

the shaft seals may become damaged or worn and must

be replaced.

WINTERIZATION

To prevent damage during freezing conditions, turn off

all electrical power.  Drain thoroughly and clean out any

debris.  Protect pump and motor from elements by

covering or, if possible, store in a dry, well ventilated

room.

TROUBLE SHOOTING

GENERAL

Your AQUA-FLO pump has been quality built and

engineered to give maximum efficiency under normal

water pumping conditions.  Consult the manufacturer for

any other applications.

LOCATION OF PUMP

For best pump performance, locate the system as close

to the water source as possible.  Provide adequate

access around the pump for inspection and mainte-

nance.

MODELS LESS TRAP

This model was designed for below water level (flooded

suction) applications.  Make sure the pump is installed

at a level that will allow the pump casing (volute) to

completely fill with water.

Two quick disconnect compression fittings are included

with your pump for ease of installation and mainte-

nance.  Make sure the fittings are correctly aligned with

pump connections to allow the O-ring to make the

proper seal.  

Hand tighten only.  Do not use a wrench

to tighten fittings.

MODELS WITH TRAP

Avoid excessive tightening of pipe or fittings in threaded

suction port in trap.  For threaded connection, use

Quick-Seal Teflon Thread Sealing Compound, Plasto-

MOTOR WILL NOT START:

1.)  Check Circuit Breakers

2.)  Check for incorrect or loose wire connections.

3.)  Make sure the correct power supply is being used.

4.)  Any on/off switch or pneumatic switch should be in

the "on" mode.

MOTOR OVERHEATING AND CYCLING ON AND OFF:

1.)  Check for incorrect or loose wire connections.

2.)  Check for low voltage supply (frequently caused by

undersized wire).

3.)  Make sure the motor gets a fresh air supply and the

vents are kept unclogged.

MOTOR MAKES HUMMING NOISE BUT WILL NOT

START:

1.)  Make sure motor shaft turns free.

2.)  Check for jammed impeller or an obstruction in

(volute) casing.

3.)  Check for low voltage and undersized wire.

PUMP WILL NOT PRIME:

1.)  Make sure pump is installed at the proper level and

the plumbing lines have been correctly installed to

allow the water to enter pump freely.

WARNING - All electrical wiring of the motor installation must be done by a qualified electrician in accordance with

applicable electrical codes.  Before working on any motor, be certain that the source of electrical power is off at the

main junction box.

BONDING WIRE - Upon installation of the pump, the motor must be bonded with a No. 8 AWG (8.4mm

2

) solid copper

conductor per National Electric Code.  The connection should be from the accessible wire connector on the motor

to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit and

metal piping within 5 feet (1.5m) of the inside walls of a swimming pool, spa or hot tub, when the motor is installed

within 5 feet of the inside walls of the swimming pool, spa, or hot tub.

NOTE:  For electrical connections, see wiring diagram on motor rating plate.

Summary of Contents for Tub-Master Series

Page 1: ...h that it cannot be readily disassembled for storage OWNER S MANUAL 06 02 TUB MASTER SERIES PUMPS When installing and using this electrical equipment basic safety precautions should always be followed including the following A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity and has a maximum dimension of 18 feet 5 49m and a ...

Page 2: ...te nance MODELS LESS TRAP This model was designed for below water level flooded suction applications Make sure the pump is installed at a level that will allow the pump casing volute to completely fill with water Two quick disconnect compression fittings are included with your pump for ease of installation and mainte nance Make sure the fittings are correctly aligned with pump connections to allow...

Page 3: ...r being replaced if available If the part number of the part to be replaced is not known use the chart below as a guideline for replacement of impellers wet ends Contact Aqua Flo Customer Service Dept 909 591 7453 If in question refer to motor label p m u P f o s t i g i d 5 t s r i F l e d o M S U z H 60 Hz 0 5 r e l l e p m I r e l l e p m I r e l l e p Im d n e t e W x x x 7 0 8 1 0 x x x 7 0 7...

Page 4: ...ace if reusing the same assemblies NOTE IT IS ADVISABLE TO REPLACE THE COMPLETE SEAL ASSEMBLY BOTH THE CERAMIC AND CARBON SIDES EVERY TIME THE PUMP IS DISASSEMBLED Removing the Seal Assemblies 1 Remove the seal rotating assembly from the impeller by carefully sliding it off of the impeller sleeve 2 Remove the ceramic ring and rubber boot by knocking it out and or prying it loose through the rear o...

Page 5: ...d used by AQUA FLO in its products may carry warranties by the original manufacturers 3 AQUA FLO is not liable for incidental or consequential damages loss of time inconvenience incidental expenses labor or material charges in connection with removal or replacement of the equipment AQUA FLO is not responsible for any implied warranties or representations by others and the foregoing warranty is exc...

Reviews: