(I) TECHNICAL SPECIFICATIONS

(J) PARTS LIST

Category

AQUV-8

AQUV-12

AQUV-20

Maximum flow rate @ 30 mJ/cm

2

* 8 gpm / 30 lpm

12 gpm / 45 lpm 20 gpm / 75 lpm

Maximum flow rate @ 40 mJ/cm

2

* 5 gpm / 19 lpm

8 gpm / 30 lpm

12 gpm / 45 lpm

Lamp service life

9000 Hours

Lamp Power

35 watt

45 watt

65 watt

Power Consumption

35 watt

45 watt

65 watt

Annual lamp change timer

Yes

Lamp-ON Indicator

Yes

Audio/Visual alarms

Yes

Chamber material

304 Stainless Steel

Chamber dimensions (D x L)

3.5” x 16.0”

3.5” x 20.0”

3.5” x ” 31.125"

Controller dimensions (L x W x D)

8” x 3” x 2.25”

Inlet/Outlet port size

3/4"NPT

1" NPT

AC supply voltage

120V, 50/60Hz, 0.8A

Maximum operating pressure

100psi

Water temperature range

2 - 40°C (36-104°F)

Shipping Weight

9lb / 4kg

10lb / 4.5kg

13lb / 5.9kg

Replacement Parts

System

AQUV-8 AQUV-12 AQUV-20

Item #

40030101 40030102 40030103

Lamp

89112

89113

89114

QuartzDome

36003037 36003038 36003039

Controller

40020068 40020068 40020068

AQUV-8, AQUV-12, AQUV-20

ITEM AS 

LABELLED PART NUMBER

DESCRIPTION

QTY

1

40020068

Ballast, power cord & lamp 

connector assembly

1

2

430335

SS UV Chamber for AQUV-8

1

3

430336

SS Chamber for AQUV-12,

1

4

430337

SS Chamber for AQUV-20

1

5

With Chamber

Mounting Clamps

2

Gland Nut

1 (2 for AQUV-20)

6

32701076

#10 SS Screws

6

7

36003037

Quartz Dome for AQUV-8

1

8

36003038

Quartz Dome for AQUV-12

1

9

36003039

Quartz Dome for AQUV-20

1

10

80127301

Gland Nut O-Ring (Thinner)

1 (2 for AQUV-20)

11

80127302

Dome O-Ring (Thicker)

1 (2 for AQUV-20)

12

89112

UV Lamp for AQUV-8

1

13

89113

UV Lamp for AQUV-12

1

14

89114

UV Lamp for AQUV-20

1

15

80127402

Lamp Spring

1

 *Dosage based on a UVT value of 96%

Summary of Contents for AQUV-12

Page 1: ...n only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local plumbing codes 3 Test the water periodically to verify that the syste...

Page 2: ......

Page 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by IAPMO R T to NSF ANSI 61 for material and...

Page 4: ...roorganisms in the water are exposed to and instantly destroyed by ultraviolet light emitted by a specially engineered UV lamp Treated water flows out of the chamber and is ready for consumption See F...

Page 5: ...the power outlet by holding the plug Never pull the cord To comply with the National Electrical Code and to provide additional protection from the risk of electric shock this system should only be co...

Page 6: ...supply of 110V AC It is strongly recommended to have a dedicated electrical circuit for the UV system A CSA or equivalent certified surge protector must be installed to protect the ballast from elect...

Page 7: ...t between well pump and pressure tank If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment befo...

Page 8: ...ppropriate socket wrench 4 Mount the ballast on the wall slightly above the chamber with ballast mounting screws see Fig 3 5 Install new plumbing using Fig 3 as reference of how the final installation...

Page 9: ...ve and valves before and after UV system Check for leaks Do not proceed to next step until leaks are fixed 12 From the top of the gland nut drop the lamp spring into the quartz dome 13 Holding the top...

Page 10: ...he faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot water tank 4 Leave the ble...

Page 11: ...rformance that ensures the safety of your drinking water Using non Aqua Flo AQUV UV lamps can not only compromise the system performance but also voids your product warranty electrical and CSA certifi...

Page 12: ...gland nut 8 A dome O ring thicker and gland nut O ring thinner are included with the replacement lamp Slide gland nut O ring into the internal groove of the gland nut 9 Follow instructions 7 to 15 in...

Page 13: ...36 104 F ShippingWeight 9lb 4kg 10lb 4 5kg 13lb 5 9kg Replacement Parts System AQUV 8 AQUV 12 AQUV 20 Item 40030101 40030102 40030103 Lamp 89112 89113 89114 QuartzDome 36003037 36003038 36003039 Contr...

Page 14: ......

Page 15: ......

Page 16: ...merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those expres...

Reviews: