Maintenance
15
Aqua Exclusive
Replacing Filter Panel
5HSODFLQJ)LOWHU3DQHO
Once you have established that the screen panel is showing wear, it is important that you
replace it with a new screen panel as soon as possible. This will ensure the continued optimal
SHUIRUPDQFHRIWKHȴOWHU)ROORZWKHVWHSVEHORZWRUHSODFHWKHȴOWHUSDQHO
1. Disconnect the power supply.
2.
(QVXUHWKDWWKHZDWHUFDQGUDLQRXWRIWKHȴOWHU
3.
7XUQWKHGUXPE\KDQGXQWLOWKHIDVWHQLQJVWULSDQGȴOWHUSDQHOFODPSVDUHSRLQWLQJXS
-
wards.
4. Remove the screws from the fastening strip.
5.
/RRVHQWKHȴOWHUSDQHOFODPSV
6. Remove the drain sewer, by unscrewing the two mounting screws at the front.
7. Remove the screen panel and replace it with a new one slowly.
8. Tighten the hose clamps and fastening the strip again. Check if the assembly is attached
correctly.
9. Put the lid back on the housing.
10. Finally insert the plug in the socket and hold the button for 10 seconds. The motor and
high pressure pump are activated again.