sources” tab in the chart configuration and select a data set to be exported. If no
data sources are available, you will have to configure the log settings as described
in the corresponding chapter of this manual. Select the time period to be exported
on the right side of the window and start the export process by clicking the “Export
data” button. Enter a file name and path in the following dialog window.
8.4.
8.4.
8.4.
8.4. Automatic data export
Automatic data export
Automatic data export
Automatic data export
The automatic data export feature can be used to save data from the aquasuite
into an XML file on the hard disk or in the RAM („memory mapped file“) in a regu-
lar time interval. The automatic data export will always overwrite the previously
saved data, so the file always contains only the most recent data set. Select “Auto-
matic data export” below the “Data log” headline in the listing to access the set-
tings screen. Create a new export data set by clicking the plus symbol in the upper
right corner of the screen. Enter name, path and time interval to meet your re-
quirements. You may then add the data sources to log by clicking the plus symbol
in the “Data sources” window section. You may add an unlimited number of data
sources to each export data set, the total number of export data sets is also unlim-
ited.
9.
9.
9.
9. Sensor configuration
Sensor configuration
Sensor configuration
Sensor configuration
aquasuite: Select “Sensors” from the device list below the “VISION” entry. In the
upper area, the eighteen available sensors are displayed including current data. In
the lower area, the currently selected sensor can be configured.
Device menu: Select “Sensors” from the menu list and confirm by pressing the
right arrow key.
9.1.
9.1.
9.1.
9.1. Hardware temperature sensor
Hardware temperature sensor
Hardware temperature sensor
Hardware temperature sensor
The first sensor in the list represents the temperature sensor input of the VISION
module. The temperature can be displayed either in degree Celsius of Fahrenheit.
The log interval determines the time difference between sensor data continuously
stored in memory and thereby the time period displayed in charts.
If necessary, each temperature sensor can be calibrated by adding an offset of
±15 °C/°F.
9.2.
9.2.
9.2.
9.2. Hardware flow sensor
Hardware flow sensor
Hardware flow sensor
Hardware flow sensor
The second sensor in the list represents the flow sensor input of the VISION mod-
ule. Calibration values for sensors sold by Aqua Computer can conveniently be se-
lected from a drop-down list. Select the appropriate entry for the flow sensor con-
nected to the VISION module.
If necessary, the flow rate can be calibrated by ±10 %.