Aqua Computer high flow NEXT User And Installation Manual Download Page 7

high flow NEXT

You will find the setup program in the support section of the website under Down-
loads/Software.
The setup program checks all connected USB devices for embedded update ser-
vice periods and offers various aquasuite versions depending on detected devices.
If no device with update service for the latest aquasuite version is found, a warning
is displayed and older aquasuite versions that do not require an update service
purchase can be selected for installation. For installation and update service vali-
dation, an internet connection is required.
The latest aquasuite version may also be installed if no suitable update service pe-
riod has been found in a device. Subsequently, update service may be purchased
or an existing key may be entered within the aquasuite. These functions can be ac-
cessed in the aquasuite/Updates tab.

5.2.

5.2.

5.2.

5.2. Basic operation

Basic operation

Basic operation

Basic operation

The program  window is divided into two main areas. On the left side, a list of
“overview pages”, data quick view, data logger, device pages, aquasuite web and
aquasuite configuration is displayed, the right side shows the details of the current-
ly selected list element. The list can be hidden or restored by clicking the arrow
symbol in the upper left corner.
List elements may be minimized or maximized for easier access by clicking the title
bar. The title bars may contain various symbols that will be explained in the follow-
ing chapter.

5.3.

5.3.

5.3.

5.3. Symbols in the headlines

Symbols in the headlines

Symbols in the headlines

Symbols in the headlines

Click the plus symbol in the “Overview pages” headline to create a new
overview page.

Clicking the monitor symbol will toggle desktop mode for this overview
page. While desktop mode is active, the color of the symbol will change
to orange.
Overview page: Clicking the padlock symbol will unlock or lock this over-
view page for editing. Device: Device can not be used due to update ser-
vice problems, see “Updates and update service” for details.
Clicking the gear symbol will access the basic configuration page of the
selected list element.

In order to save all settings  into a device,  click  the disk symbol in the
headline.

This symbol indicates that communication with this device is not possible
at the moment. Check USB connection and power supply of the device if
necessary.

© 2020

Aqua Computer GmbH & Co. KG

- 7 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Summary of Contents for high flow NEXT

Page 1: ...r and installation manual high flow NEXT aquasuite version X 27 Current as of October 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2020 A...

Page 2: ...ding new elements 8 6 4 Editing existing elements 9 6 5 Values and names 9 6 6 Detailed data elements 9 6 7 Log data chart 9 6 8 User defined Images text drawing elements 9 6 9 Export and import of ov...

Page 3: ...19 13 1 Device information 19 13 2 Factory defaults 19 13 3 Basic RGBpx settings 19 13 4 USB power supply 19 13 5 aquabus configuration 19 13 6 Standby behavior 20 13 7 Firmware update and language se...

Page 4: ...malfunction of this product can reasonably be expected to re sult in personal injury Aqua Computer GmbH Co KG customers using or selling this product for use in such application do so at their own ri...

Page 5: ...vices aquaero 6 XT 53146 53206 53250 53251 53262 53263 aquaero 6 PRO 53145 53253 aquaero 6 LT 53234 aquaero 5 XT 53089 53125 53249 aquaero 5 PRO 53090 53252 aquaero 5 LT 53095 4 3 4 3 4 3 4 3 Connecto...

Page 6: ...e for devices with miniature connector 53295 Utilization as alarm output The header can be connected to the power switch header of the motherboard us ing an additional specialized cable 53216 not incl...

Page 7: ...the right side shows the details of the current ly selected list element The list can be hidden or restored by clicking the arrow symbol in the upper left corner List elements may be minimized or max...

Page 8: ...suite window for editing and the current desktop will be displayed as background for your convenience 6 2 6 2 6 2 6 2 Creating new overview pages and activating edit mode Creating new overview pages a...

Page 9: ...available Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chr...

Page 10: ...To export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import pag...

Page 11: ...can be configured To add data to the chart first select the Data sources tab in the chart configura tion and select a data set to be displayed If no data sources are available you will have to config...

Page 12: ...anual data export Manual data export Saved data can be exported from the data log into a XML file To do so select Analyze data below the Data log headline in the listing Select the Data sources tab in...

Page 13: ...rate can be displayed either in liters or gallons per hour please see chapter 9 1 for details If necessary the flow rate can be calibrated manually 8 3 8 3 8 3 8 3 Water temperature Water temperature...

Page 14: ...sors Software sensors Software sensors The last eight sensors in the list are software sensors and can be used to transmit sensor data that is not physically available to the high flow NEXT from the c...

Page 15: ...display settings Display brightness and automatic change of the displayed screen can be config ured As with all OLED displays the brightness of active pixels will reduce over time For a homogeneous we...

Page 16: ...fects can be configured to modify effect parameters depending on current sensor data In total up to eight LED controllers two for integrated lighting six for external components can be configured 10 2...

Page 17: ...te configuration can also be used to modify existing audio filters and define custom audio filters 10 7 10 7 10 7 10 7 AMBIENTpx effect AMBIENTpx effect AMBIENTpx effect AMBIENTpx effect The AMBIENTpx...

Page 18: ...be raised While an alarm condition is detected the device display will permanently show a corresponding information screen Additionally the RGBpx illumination can be configured to flash red On the al...

Page 19: ...n In default configuration power consumption is limited to a maximum current of 0 5 Amps This value complies with the maximum allowed current according to the USB spec ification If a large number of L...

Page 20: ...utomatically closed 14 14 14 14 Playground aquasuite Playground aquasuite Playground aquasuite Playground aquasuite Click the entry Playground to configure Virtual Software Sensors global profile mana...

Page 21: ...ending on running applications During configura tion of the respective rule in the aquasuite the application to be configured must already be running The application selection within the aquasuite wil...

Page 22: ...cording through third parties is possible Use the data export feature for data that you want to publish publicly and are allowed to do so only 15 2 15 2 15 2 15 2 Data access Data access Data access D...

Page 23: ...hen done 16 3 16 3 16 3 16 3 Units Units Units Units Select the units to be used for temperature and flow values from the drop down menus After changing these settings the software will have to be res...

Page 24: ...ersion It is not mandatory that each device has a corresponding update service period For update service validation the aquasuite requires an in ternet connection After successful validation a file co...

Page 25: ...tact with coolant or water 17 3 17 3 17 3 17 3 Waste disposal Waste disposal Waste disposal Waste disposal This device has to be disposed of as electronic waste Please check your local regulations for...

Reviews: