background image

FARBWERK 360

User and installation manual

User and installation manual

User and installation manual

User and installation manual

farbwerk 360

aquasuite version X.17

Current as of April 2020

All information contained in this manual is subject to change without prior notice.

All rights reserved.

© 2019-2020

Aqua Computer GmbH & Co. KG

- 1 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

ENGLISH: PAGE 1

DEUTSCH: SEITE 24

Summary of Contents for farbwerk 360

Page 1: ...and installation manual farbwerk 360 aquasuite version X 17 Current as of April 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2019 2020 Aq...

Page 2: ...mode 8 7 2 Creating new overview pages and activating edit mode 9 7 3 Adding new elements 9 7 4 Editing existing elements 9 7 5 Values and names 9 7 6 Detailed data elements 9 7 7 Log data chart 10 7...

Page 3: ...export 20 14 2 Data access 20 14 3 Data import 20 15 Basic settings aquasuite 21 15 1 Language 21 15 2 Reorder menu items 21 15 3 Units 21 15 4 Application start up 21 15 5 Service administration 21...

Page 4: ...very Scope of delivery Scope of delivery One farbwerk 360 controller Two RGBpx LED strips 32 cm width 10 mm 15 addressable LEDs replace ment part no 53268 Two RGBpx cables length 50 cm replacement par...

Page 5: ...ouble check the polarity of the plug if you are having trouble to connect Pin assignment Pin 1 not connected Pin 2 GND Pin 3 GND Pin 4 5 V 5 3 5 3 5 3 5 3 Connector USB Connector USB Connector USB Con...

Page 6: ...tor for temperature sensors Connector for temperature sensors Connector for temperature sensors Connector for up to four temperature sensors Compatible sensors Temperature sensor inline G1 4 53066 Tem...

Page 7: ...s for embedded update ser vice periods and offers various aquasuite versions depending on detected devices If no device with update service for the latest aquasuite version is found a warning is displ...

Page 8: ...ew pages aquasuite Overview pages aquasuite Overview pages aquasuite Overview pages aquasuite Current sensor readings and diagrams from all supported devices can be dis played in overview pages For ea...

Page 9: ...ments If the currently selected overview page is unlocked for editing right clicking an element will access a context menu To access the settings of an element select Settings in the context menu or s...

Page 10: ...e By clocking the Ok Button the new control is saved to the overview page Step by step example to add an image Select Image from the drop down menu and click the Load preset button Select an image fil...

Page 11: ...ttings Log settings Log settings Log settings The log settings can be accessed by clicking the Log settings element below the Data log headline in the listing To log data create a new log data set by...

Page 12: ...you may edit the text You may also drag the little circle beside the text box to move the connecting line to the desired position Use drag and drop to move existing annotations This function can be us...

Page 13: ...urrently selected sensor can be configured 9 1 9 1 9 1 9 1 Hardware temperature sensors Hardware temperature sensors Hardware temperature sensors Hardware temperature sensors The first four sensors in...

Page 14: ...oftware sensor For each software sensor a scale factor and an offset may be configured for ma nipulation of the displayed sensor value Data from third party software regularly requires the scale facto...

Page 15: ...vated or deactivated for each of the four available profiles as well By clicking the gear symbol the effect to be displayed can be changed and the controller name can be altered Confirm you selection...

Page 16: ...escribed above this is always the LED controller the furthest up in the list of controllers However the opacity of almost all color definitions in the LED controllers can be individually configured re...

Page 17: ...o be activated by clicking the corresponding button 11 2 11 2 11 2 11 2 Automatic profile selection Automatic profile selection Automatic profile selection Automatic profile selection The active profi...

Page 18: ...asuite Click the entry Playground to configure Virtual Software Sensors global profile management and hotkeys 13 1 13 1 13 1 13 1 Virtual Software Sensors Virtual Software Sensors Virtual Software Sen...

Page 19: ...ng on running applications During configura tion of the respective rule in the aquasuite the application to be configured must already be running The application selection within the aquasuite will al...

Page 20: ...ding through third parties is possible Use the data export feature for data that you want to publish publicly and are allowed to do so only 14 2 14 2 14 2 14 2 Data access Data access Data access Data...

Page 21: ...done 15 3 15 3 15 3 15 3 Units Units Units Units Select the units to be used for temperature and flow values from the drop down menus After changing these settings the software will have to be restar...

Page 22: ...ion It is not mandatory that each device has a corresponding update service period For update service validation the aquasuite requires an in ternet connection After successful validation a file conta...

Page 23: ...ntact with coolant or water 16 3 16 3 16 3 16 3 Waste disposal Waste disposal Waste disposal Waste disposal This device has to be disposed of as electronic waste Please check your local regulations fo...