5
MODES OF OPERATION
To Change Between Pool and Spa Setpoints Manually:
This is the default factory setting (jumper on pins 1-2) and allows the user to change between the pool
and spa setpoints by using the mode button located on the front control panel. The use of an external
water pressure switch
IS
NOT
required for this mode of operation.
To Change Between Pool and Spa Setpoints Automatically:
This change can be done automatically as the water flow is directed to either the pool or spa. The use
of an external water pressure switch in the spa piping
IS
necessary. A two-wire control circuit must be
connected from the water pressure switch to the terminals 9 and 10 on the terminal strip located in the
electrical control enclosure. The mode jumper must be on pins 2-3 for this mode of operation. See
figure 1 below for pin settings.
Remote Thermostats and Controllers:
If a remote thermostat or another control system is to be used to operate the heater, a normally open
dry contact can be made at terminals 11 and 12 on the terminal strip located in the electrical control
enclosure. Remove the red jumper from terminals 11 and 12 on the terminal strip and install the
remote control system. The mode jumper must be on pins 3-4 for this mode of operation. See figure 1
below for pin settings.
Mode
Configuration Pins
2
3
4
1
Electronic
Controller
Removable
Jumper
Terminal
Strip
1
2
3
4
5
6
7
8
9
10
11
12
Figure 1 – Terminal Strip & Mode Configuration Pins