MODES OF OPERATION 

 
 

To Change Between Pool and Spa Setpoints Manually: 

This is the default factory setting (jumper on pins 1-2) and allows the user to change between the pool 
and spa setpoints by using the mode button located on the front control panel.  The use of an external 
water pressure switch 

IS

 

NOT

 required for this mode of operation.   

 

To Change Between Pool and Spa Setpoints Automatically: 

This change can be done automatically as the water flow is directed to either the pool or spa.  The use  
of an external water pressure switch in the spa piping 

IS

 necessary.  A two-wire control circuit must be 

connected from the water pressure switch to the terminals 9 and 10 on the terminal strip located in the  
electrical control enclosure.  The mode jumper must be on pins 2-3 for this mode of operation.  See  
figure 1 below for pin settings. 
 

Remote Thermostats and Controllers:  

If a remote thermostat or another control system is to be used to operate the heater, a normally open  
dry contact can be made at terminals 11 and 12 on the terminal strip located in the electrical control  
enclosure.  Remove the red jumper from terminals 11 and 12 on the terminal strip and install the  
remote control system.  The mode jumper must be on pins 3-4 for this mode of operation.  See figure 1 
below for pin settings. 

                                                                           

     

Mode

Configuration Pins

2

3

4

1

Electronic

Controller

Removable

Jumper

Terminal

Strip

1

2

3

4

5

6

7

8

9

10

11

12

 

                                        Figure 1 – Terminal Strip & Mode Configuration Pins

 

Summary of Contents for AC1050

Page 1: ...ENERAL INFORMATION 2 INSTALLATION 2 WATER FLOW CONNECTIONS 2 3 ELECTRICAL CONNECTIONS 4 MODES OF OPERATION 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL PANEL 7 CHEMICAL USE 8 START UP 9 10 MAINTENANCE 10 TR...

Page 2: ...ng a location consider the following Heater must be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Mini...

Page 3: ...g time is allowed run the filter pump and check the entire system for water leaks Make sure filter is clean and there are no obstructions in the filtering system Proper water flow is essential to the...

Page 4: ...s from the front panel of the control box 3 Route weather tight flexible conduit through the opening at the base of the unit Connect conduit to the bottom of the electrical control enclosure A knockou...

Page 5: ...pressure switch to the terminals 9 and 10 on the terminal strip located in the electrical control enclosure The mode jumper must be on pins 2 3 for this mode of operation See figure 1 below for pin s...

Page 6: ...1 FS2 Field Installed Flow Switch See Table 1 Remote Automation Jumper P1 P2 P3 PIN 1 2 3 Field Installed home automation control See Table 1 See Table 1 Fan1 Interface Panel 9 10 11 12 TS 4 Green 5 6...

Page 7: ...ther POOL or SPA mode this will prompt the control to display the current temperature setpoint Hold either UP or DOWN button to scroll to your desired temperature setpoint Once your new temperature se...

Page 8: ...chlorinators must be piped downstream from the heater A check valve must be installed between the chlorinator and heater to prevent raw chlorine from draining back into the heater A chemical trap may...

Page 9: ...n actual water temperature and desired water temperature Size of pool Ambient air temperature the cooler the air temperature the longer the heating time Heat loss evaporative convective radiative and...

Page 10: ...ter quality Free airflow is essential Keep the evaporator coil clean and free of weeds leaves glass clippings dirt and other debris that will decrease the airflow Keep fences and shrubs away from air...

Page 11: ...nic control display In the event that an error does occur check the possible causes list for the corresponding error to correct the problem Error Code Description Possible Causes F1 Internal Flow Swit...

Page 12: ...factory representative will assist you or your serviceman over the phone SERVICE PERFORMED WITHIN THE WARRANTY PERIOD MUST BE APPROVED BY AQUA COMFORT TECHNOLOGIES LLC PRIOR TO SERVICE BEING PERFORMED...

Reviews: