background image

9

LIGHTING INSTRUCTIONS

HMG Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the European 
Community). Please follow the instructions for your unit. HMG Griddles are furnished with either a flame 
failure pilot or a standing pilot (not available in the European community).

Pilot Operation HMG Flame Failure Gas Valve:

Operation of the gas valve pilot:

1.

Turn knob on the main gas valve to the pilot position

2.

Depress knob to start gas flow to the pilot valve

3.

Light pilot valve
a. Using a match or taper

4.

Hold in knob for 15 to 30 seconds to heat up the thermocouple

5.

Release knob and turn to the desired gas flow position
a.  If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up

Standing Pilot Lighting Instructions:

 ( Not Available in the European Community )

The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first lighting 
to adjust the flame for your elevation.

1.

Turn off the manual shut off valve and wait 5 minutes to clear the gas.

2.

Turn all knobs to the “OFF” position.

3.

The valve can be accessed through an opening in the front panel or remove the cooking grates 

and light the pilot from above.

4.

Turn the manual shut off valve on.

5.

Hold  an  ignition  source  (match)  to  both  openings  on  the  pilot  tube.  When  the  flames  are 
established, remove the ignition source. 

6. 

Turn the burner knobs to “HI”. If the burner does not ignite, promptly open the pilot valve more. If 
the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot 
flame  should  be  as  small  as  possible  but  large  enough  to  guarantee  reliable  ignition  of  the 
burners when the knobs are turned to “HI”. 

RELIGHTING PILOT

If the pilot light should go out for any reason:

l

Promptly shut off all gas at the manual shut off valve.

l

Turn off all knobs and pilot valves; wait 5 minutes to clear gas. 

l

Relight following steps 4 through 6 under Standing Pilot Lighting Instructions. 

HMG LIGHTING MAIN BURNER:

Since the burner is lit from constantly burning pilot, turn knobs to “HI” to put the unit in operation; then adjust 
to any desired position between “LO” and “HI”. 

l

To light burner, turn knob to “max.” then back off to the desired flame level. The range of adjustment is 

virtually infinite between high and off.  (At the small flame, there is a pre-set low).

l

When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from 

storage and shipping are burned off.  An hour at “max.” on all burners is usually sufficient.

l

Turn knobs off and let cool

l

For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have to 

experiment with knob settings and grate position for each particular item.

l

Clean regularly. Grates may be removed for washing in the sink. Brush out carbonized particles. 

Thoroughly wash the grease/water pan. 

European Community

If  adjustment  becomes  necessary  in  the  field,  it  should  be  done  by  a  factory  authorized  and  trained 
technician who should seal the screw after the adjustment to safeguard against unauthorized tampering by 
the end user.

Summary of Contents for HMG-2424

Page 1: ...ther appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroug...

Page 2: ...and liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles SeeANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Page 3: ...its operation is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manu...

Page 4: ...connected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGIS...

Page 5: ...MG 2436 36 914 4 38 09 967 5 15 460 392 7 3 32 000 9 78 96 000 28 1 5 12 4 HMG 2448 48 1219 2 38 48 977 4 15 460 392 7 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460 60 1524 0 38 09 967 5 15 460 392 7 5 3...

Page 6: ...8 23 58 13 13 32 38 4 21 36 MANUAL GRIDDLE 32 92 6 27 38 48 48 0 45 000 15 46 13 13 32 38 4 61 23 58 33 88 48 MANUAL GRIDDLE 6 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2436 21826100 SPECIFICATIONS HE...

Page 7: ...E HMG 2460 21826300 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2472 21826400 43 54 60 0 6 27 38 09 57 00 15 46 13 13 32 38 4 21 23 58 33 88 60 MANUAL GRIDDLE 44 92 72 0 6 27 38 21 69 00 15 46 33 88 13...

Page 8: ...a monthly basis blow off any dust or grease which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere 8 NAT LP CONVE...

Page 9: ...ilot valve more If the pilot flame appears larger than necessary turn it down and reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliable ignition o...

Page 10: ...e in your area OPERATING INSTRUCTIONS Season Griddle Heat to low temperature 300 350 F 150 180C and pour on a small amount of cooking oil about one ounce 30cc per square foot of surface Spread the oil...

Page 11: ...emoved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry c...

Page 12: ...set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Heat is set too high...

Page 13: ...ODY 36 FIREBOX 1 21826222 BODY 48 FIREBOX 1 21826322 BODY 60 FIREBOX 1 21826422 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNE...

Page 14: ...ACK 72 1 20 21826015 PANEL CONTROL 24 1 21826115 PANEL CONTROL 36 1 21826215 PANEL CONTROL 48 1 21826315 PANEL CONTROL 60 1 21826415 PANEL CONTROL 72 1 21 2065848 VENTURI HVY DTY GRIDDLES 2 3 4 5 6 22...

Page 15: ...EBOX 1 21826236 BODY 48 FIREBOX 1 21826336 BODY 60 FIREBOX 1 21826436 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNER 2 218264...

Page 16: ...21826452 PANEL BACK 72 1 20 21826040 PANEL CONTROL 24 CE 1 21826140 PANEL CONTROL 36 CE 1 21826240 PANEL CONTROL 48 CE 1 21826340 PANEL CONTROL 60 CE 1 21826440 PANEL CONTROL 72 CE 1 21 2065849 VENTU...

Page 17: ...45 20932101 NUT COMPRESSION FERRULE 2 3 4 5 6 46 21826016 BRACKET THERMOCOUPLE 2 3 4 5 6 47 21826046 TUBE PILOT SUPPLY CE 2 3 4 5 6 48 21826047 TUBE ORIFICE SUPPLY 2 3 4 5 6 49 8806070 LABEL DELIVERY...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...f connection or use atAPWWyott soptionoritsAuthorizedServiceAgency itwillbeservicedonsiteorreplaced From day two through the conclusion of this warranty period portable units must be taken to or sent...

Page 21: ...www apwwyott com Dallas Plant 729 Third Ave Dallas TX 75226 Local 1 214 421 7366 Toll Free 1 800 527 2100 Parts Service Fax 1 214 565 0976 Cheyenne Plant 1938 Wyott Drive Cheyenne WY 82007 Local 1 307...