background image

 

 

 

 

 

 

 

 

 

 

TABLE OF CONTENTS:

2

ITEM

PAGE

Safety Precautions .......................................3
General Installation Instructions...................4
Specifications & Dimensions........................5
Conversion ...................................................8
Lighting Instructions .....................................9
Operating Instructions .................................10

ITEM

PAGE

Cleaning/Maintenance ......................................11
Service/Repair ..................................................11
Troubleshooting Guide......................................12
Replacement Parts Lists & Exploded View.......13
Warranty ...........................................................20

LOCATION OF DATA PLATE

The data plate is located on the right side panel.

CAUTION:

  These  models  are  designed,  built,  and  sold  for  commercial  use.  If  these 

   

models  are  positioned  so  the  general  public  can  use  the  equipment,  make  sure  that 
cautions, warnings, and operating instructions are clearly posted near each unit so that 
anyone using the equipment will use it correctly and not injure themselves or harm the 
equipment.

WARNING:

  Improper  installation,  adjustment,  alteration,  service  or  maintenance  can 

cause  property  damage,  injury  or  death.  Read  the  installation,  operating  and       
maintenance instructions thoroughly before installing,  or servicing this equipment.

WARNING:

 For your safety do not store or use gasoline or other flammable vapors and 

liquids  in  the  vicinity  of  this  or  any  other  appliance.  Keep  the  area  free  and  clear  of 
combustibles. (See ANZI Z83. 14B, 1991).

NOTICE:

 Instructions to be followed if anyone smells gas should be posted in a prominent 

place. These may be obtained from the gas supplier.

GAS PRESSURE

The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from the gas 
supply  piping  system  during  any  pressure  testing  of  that  system  at  test  pressures  in  excess  of  ½  psi           
(3.45 kPa).

The appliance must be isolated from the gas supply piping system by closing it’s individual manual shut-off 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than         
½ psi (3.45 kPa). 

WARNING:

 A factory authorized agent should handle all maintenance and repair. Before 

doing any maintenance or repair, contact APW Wyott.

Congratulations  on  your  purchase  of  APW  Wyott  commercial  cooking  or  refrigeration  equipment.                 
APW Wyott takes pride in the design and quality of our products. When used as intended and with proper 
care and maintenance, you will experience years of reliable operation from this equipment.  To ensure best 
results, it is important that you read and follow the instructions in this manual carefully.

Summary of Contents for HMG-2424

Page 1: ...ther appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroug...

Page 2: ...and liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles SeeANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Page 3: ...its operation is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manu...

Page 4: ...connected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGIS...

Page 5: ...MG 2436 36 914 4 38 09 967 5 15 460 392 7 3 32 000 9 78 96 000 28 1 5 12 4 HMG 2448 48 1219 2 38 48 977 4 15 460 392 7 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460 60 1524 0 38 09 967 5 15 460 392 7 5 3...

Page 6: ...8 23 58 13 13 32 38 4 21 36 MANUAL GRIDDLE 32 92 6 27 38 48 48 0 45 000 15 46 13 13 32 38 4 61 23 58 33 88 48 MANUAL GRIDDLE 6 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2436 21826100 SPECIFICATIONS HE...

Page 7: ...E HMG 2460 21826300 SPECIFICATIONS HEAVY DUTY GAS GRIDDLE HMG 2472 21826400 43 54 60 0 6 27 38 09 57 00 15 46 13 13 32 38 4 21 23 58 33 88 60 MANUAL GRIDDLE 44 92 72 0 6 27 38 21 69 00 15 46 33 88 13...

Page 8: ...a monthly basis blow off any dust or grease which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere 8 NAT LP CONVE...

Page 9: ...ilot valve more If the pilot flame appears larger than necessary turn it down and reset burner ignition The pilot flame should be as small as possible but large enough to guarantee reliable ignition o...

Page 10: ...e in your area OPERATING INSTRUCTIONS Season Griddle Heat to low temperature 300 350 F 150 180C and pour on a small amount of cooking oil about one ounce 30cc per square foot of surface Spread the oil...

Page 11: ...emoved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry c...

Page 12: ...set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Heat is set too high...

Page 13: ...ODY 36 FIREBOX 1 21826222 BODY 48 FIREBOX 1 21826322 BODY 60 FIREBOX 1 21826422 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNE...

Page 14: ...ACK 72 1 20 21826015 PANEL CONTROL 24 1 21826115 PANEL CONTROL 36 1 21826215 PANEL CONTROL 48 1 21826315 PANEL CONTROL 60 1 21826415 PANEL CONTROL 72 1 21 2065848 VENTURI HVY DTY GRIDDLES 2 3 4 5 6 22...

Page 15: ...EBOX 1 21826236 BODY 48 FIREBOX 1 21826336 BODY 60 FIREBOX 1 21826436 BODY 72 FIREBOX 1 4 21826017 SUPPORT BURNER 2 21826117 SUPPORT BURNER 2 21826217 SUPPORT BURNER 2 21826317 SUPPORT BURNER 2 218264...

Page 16: ...21826452 PANEL BACK 72 1 20 21826040 PANEL CONTROL 24 CE 1 21826140 PANEL CONTROL 36 CE 1 21826240 PANEL CONTROL 48 CE 1 21826340 PANEL CONTROL 60 CE 1 21826440 PANEL CONTROL 72 CE 1 21 2065849 VENTU...

Page 17: ...45 20932101 NUT COMPRESSION FERRULE 2 3 4 5 6 46 21826016 BRACKET THERMOCOUPLE 2 3 4 5 6 47 21826046 TUBE PILOT SUPPLY CE 2 3 4 5 6 48 21826047 TUBE ORIFICE SUPPLY 2 3 4 5 6 49 8806070 LABEL DELIVERY...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...f connection or use atAPWWyott soptionoritsAuthorizedServiceAgency itwillbeservicedonsiteorreplaced From day two through the conclusion of this warranty period portable units must be taken to or sent...

Page 21: ...www apwwyott com Dallas Plant 729 Third Ave Dallas TX 75226 Local 1 214 421 7366 Toll Free 1 800 527 2100 Parts Service Fax 1 214 565 0976 Cheyenne Plant 1938 Wyott Drive Cheyenne WY 82007 Local 1 307...

Reviews: