![APW Wyott HFW-1DS Owner'S Manual Download Page 6](http://html1.mh-extra.com/html/apw-wyott/hfw-1ds/hfw-1ds_owners-manual_2957715006.webp)
2M-Z24235 Owners Manual for Built-In Hot Food W
ell W
armers
NOTE:
DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation. Refer to
SHIPPING DAMAGE CLAIM
PROCEDURE on the inside
front cover of this manual.
WARNING:
RISK OF INJURY
Installation procedures must
be performed by a qualified
technician with full knowledge
of all applicable electrical and
plumbing codes. Failure can
result in personal injury and
property damage.
CAUTION
FIRE HAZARD
Avoid storing flammable or
combustible materials in, on or
near the appliance.
IMPORTANT:
For warmers
installed in plastic counter
tops, the counter material
must be protected from the
heat of the warmer in order
to prevent discoloration and/
or deterioration. E-Z Lock are
not suitable for this purpose.
The installer should contact
the manufacturer or distributor
of the countertop material for
specific instructions.
IMPORTANT:
E-Z Lock
Extension Kits must be
used ONLY with UL Listed
warmers approved for
installation in wood counter
tops. Refer to the Installation
Instructions provided with the
warmer.
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic film, packing materials and accessories from the Appliance
before connecting electrical power or otherwise performing any
installation procedure.
Carefully read all instructions in this manual and the Installation
Instruction Sheet packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the unit.
Carefully account for all components and accessories before discarding
packing materials. Store all accessories in a place for later use.
INSTALLATION NOTES
1. Installation and start up of built-in warmers MUST be performed
by an authorized installation company.
2. It is the responsibility of the installer to verify that this warmer
installation is in compliance with the specifications listed in this
manual and on the specification sheet provided.
3. It is the RESPONSIBILITY OF THE INSTALLER to check with
the authority having jurisdiction, in order to verify that this warmer
installation is in compliance with local code requirements.
4. Water supply and drain installation must meet all applicable
local, state and federal plumbing codes and ordinances.
5. Refer to Installation Instructions included with the warmer for
Underwriters Laboratories conditions of acceptability, electrical
requirements and other installation concerns.
BUILT-IN WARMERS
1. This is a GENERAL GUIDE. For specific cutout dimensions
and other installation details, refer to the Installation Instructions
supplied with the warmer.
2. Cutout dimensions for warmer units and control panels are listed
on the Installation Instructions provided with the warmer.
NOTE:
Cutout dimensions are different for auto-fill and non auto-fill
units, control panels, and for wood and metal counters. Verify the
dimensions are correct for the installation before making the cutout.
Specific cutout specifications are list on the installation sheet included
with the unit.
3. For “top-mounted” warmers (i.e. warmers mounted from above the
counter top):
a. Verify that provided sealants are applied to the underside of the
warmer top flange prior to setting the unit into the cutout.
b. After installation, verify that the tabs on the E-Z Lock are turned
out to lock the warmer into the counter.
c. Apply a thin bead of food-grade silicone sealant around the flange
to seal it to the counter.
d. E-Z Lock extension kits are available for installing warmers in
counter tops where the standard E-Z Lock would not normally
reach. The extension kit will adapt to counter tops up to 1¾” thick.
INSTALLATION