APW Wyott HFW-1DS Owner'S Manual Download Page 1

HFW-2S

BUILT-IN WELL HOT FOOD WELLS

WITH INFINITE THERMOSTAT 

MODELS:

HFW-1S, HFW-1DS, HFW-2S, HFW-2DS, HFW-3S,

HFW-3DS, HFW-4S, HFW-4DS, HFW-5S, HFW-5DS

OWNERS MANUAL

2M-Z24235 Rev. -  05/21

is a registered trademark of APW Wyott®, A Middleby Company.  All rights reserved.

This manual includes material related to installation, use , cleaning, and care. Exploded view[s], as well as any available 

parts list[s] and wiring diagram[s] pertaining to the unit[s] covered by this manual are also included.
This manual must be read and understood by all persons using or installing this appliance. Contact your APW Wyott 

dealer if you have any questions concerning installation, use, or maintenance of this equipment.
DO NOT DISCARD THIS MANUAL.

HFW-1S

Summary of Contents for HFW-1DS

Page 1: ...his manual includes material related to installation use cleaning and care Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covered by this manual ar...

Page 2: ...oltage or gas type Normal Business Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www apwwyott com WARRANTY EXCLUSIONS THE FOLLOWING WI...

Page 3: ...his manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS INTRODUCTION...

Page 4: ...is the lowest temperature setting PREHEAT is a continuous on setting Infinite switch controlled warmers are equipped with a hi limit device to prevent overheating The hi limit will self reset after th...

Page 5: ...e use limitations and associated restrictions Operating instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sa...

Page 6: ...d start up of built in warmers MUST be performed by an authorized installation company 2 It is the responsibility of the installer to verify that this warmer installation is in compliance with the spe...

Page 7: ...me jurisdictions may require an approved air gap or other back flow prevention device in the drain It is the responsibility of the plumber to determine such requirement to provide and properly install...

Page 8: ...tely 30 minutes then set the control for the desired temperature Be sure to keep the warmer covered during preheat and operation AUTOFILL WARMERS 1 Autofill warmers sense water level by a sensor place...

Page 9: ...NOT place food directly into the warmer 2 Check water level in wet operation warmer frequently during use Running warmers dry will lower the temperature of the food in the insert pan and may damage t...

Page 10: ...r 2 Check water level in wet operation warmer frequently during use Running warmers dry will lower the temperature of the food in the insert pan and may damage the warmer 3 Alternating between wet and...

Page 11: ...ans insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless s...

Page 12: ...rgent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating elem...

Page 13: ...overs accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control...

Page 14: ...yott Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match voltage on war...

Page 15: ...ns insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless st...

Page 16: ...2M Z24235 Owners Manual for Built In Hot Food Well Warmers EXPLODED VIEW HFW 1S HFW 1DS IL1905e 05 21 1 THERMOBULB 5 21 6 7 8 9 11 11 10 18 19 17 16 15 14 13 20 12 13 22 12 3 2 14...

Page 17: ...5066 1 SHROUD WRAP ROHS HFW 1S 8 P2 45067 1 SHROUD FR ROHS HFW 1S 9 P2 45186 1 SHROUD BOT ROHS 10 5P 21709 1 SCREEN DRAIN WARMERS ALL 11 P2 30401 1 PAN W O DRAIN HFW 1S P2 30402 PAN W DRAIN HFW 1DS HF...

Page 18: ...or Built In Hot Food Well Warmers EXPLODED VIEW PARTS LIST 16 3 6 7 8 9 10 5 1 37 3 2 4 16 15 21 24 25 17 25 24 23 22 11 12 13 14 18 20 10 19 AutoFill Units Only 26 29 27 28 30 34 36 35 T units only 3...

Page 19: ...2J 30385 LIGHT SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12288 PANEL CONTROL 1 T STAT INFINITE UNITS NON AF P2 Z12589 PANEL CONTROL 1 AUTOFILL UNITS 16 E7 4...

Page 20: ...EMENT M227 T STAT 32 WS 50396 ELEM 120V 1200W 2 HFW 2S INFINITE 120V WS 50398 ELEM 240V 1200W M P HFW 2S INFINITE 240V 2N 46681UL ELEM 120V 1650W HFW 2S T STAT 120V 2N 303375UL ELEM HEATING 240V 1650W...

Page 21: ...BLOCK KIT RETRO 30131 1 INFINITE AUTOFILL UNITS 13 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 AUTOFILL UNITS 14 2J 30385 LIGHT SIGNAL GLO DOT RED 3 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS...

Page 22: ...1 KIT ELEM PAN W ELEMENT 2 HFW 3S T STAT NARROW P2 WL0072 PAN ELEM ASSY MID 1 32 WS 50396 ELEM 120V 1200W 3 HFW 3S INFINITE 120V 2N 46681UL ELEM 120V 1650W HFW 3S T STAT 120V 33 WS 55707 COVER ELEM WA...

Page 23: ...T SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12591 PANEL CONTROL 1 INFINITE UNITS NON AF P2 Z12584 PANEL CONTROL HFW 4S T STAT DRAIN MANIFOLD AUTOFILL 16 P2...

Page 24: ...NT 208 240 4 HFW 4S T STAT 32 WS 50398 ELEM 240V 1200W M P 4 HFW 4S INFINITE 240V 2N 303375UL ELEM HEATING 240V 1650W HFW 4S T STAT 240V 33 WS 55707 COVER ELEM WARMER 4 HFW 4S INFINITE UNITS WS 503842...

Page 25: ...ITE AUTOFILL UNITS 13 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 AUTOFILL UNITS 14 2J 30385 LIGHT SIGNAL GLO DOT RED 2 INFINITE UNITS 2J 35687 LIGHT SIGNAL GLO DOT T STAT UNITS 15 P2 Z12594 PANEL CONTROL 1...

Page 26: ...LEM 240V 1200W M P 5 HFW 5S INFINITE 240V 2N 303375UL ELEM HEATING 240V 1650W HFW 5S T STAT 240V 33 WS 55707 COVER ELEM WARMER 5 HFW 5S INFINITE UNITS WS 503842 KIT ELEM PAN W O ELEMENT HFW 5S T STAT...

Page 27: ...N 12847 0 030 MOD 300 DIAGRAM WIRIN ENG REL ECN 855 G UNLESS NOTED DEC TOL PART NAME USED ON DO NOT SCALE DWG ISSUE WAS Z H 60 50 SINGLE PHASE 15 0 13 0 8 7 7 5 8 7 7 5 4 2 1 3 1 16 14 15 13 12 11 TER...

Page 28: ...ILOT LIGHT 4 11 7 8 12 14 2 H 2 1 L L P H1 H2 P L L 1 2 1 H H2 P 2 1 L L H1 H2 3 1 2 2 1 Z H 60 50 SINGLE PHASE 25 0 21 6 13 0 11 2 13 0 11 2 4 3 2 1 20 THREE PHASE 240 17 0 7 4 10 15 0 208 SK3024 WIR...

Page 29: ...G ELEMENT 2 7 1 4 WIRE CONNECTOR 6 TERM BLOCK L1 L2 L3 OPTIONAL CORD WHITE FROM CORD BLACK FROM CORD GREEN FROM CORD PILOT LIGHT TERM BLOCK THERMOSTAT 3 PILOT LIGHT 3 L1 L2 L3 REV E P N 2M 48589 240 2...

Page 30: ...L1 L2 L3 THREE PHASE PHASE SINGLE 50 60 HZ 14 5 14 5 9 8 17 8 17 8 11 3 23 8 27 5 WIRING DIAGRAM Thermostat Control Units TERM BLOCK THERMOSTAT 5 PILOT LIGHT 5 L1 L2 L3 REV D P N 2M 48604 HEATING ELEM...

Page 31: ...CE DESCRIPTION PART NO ADAPTERS INSETS ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets 21623 4 QT ROUND INSET w lid 20774 11 QT ROUND INSET w lid 20908 11 QT ROUND INSET w hinged lid 21057...

Page 32: ...o wood counter up to 1 thick 22593 E Z Lock Extension Kits for UL Listed units approved for installation in wood counter tops One well units require one kit Two and three well units require two kits f...

Page 33: ...2M Z24235 Owners Manual for Built In Hot Food Well Warmers NOTES...

Page 34: ...265 Hobson St Smithville TN 37166 Telephone 800 527 2100 Printed in the U S A 2M Z24235 Rev 05 21 Specifications are subject to change without notice is a registered trademark of APW Wyott A Middleby...

Reviews: