APW Wyott HDCB-2424i Operating Instructions Manual Download Page 7

or grease which may accumulate around this cap. The openings must remain open for the regulator to 
function. Clean more often in a very greasy atmosphere. 

LIGHTING INSTRUCTIONS 

HDCB and HDCRB Broilers are furnished with either a pilot safety valve or a standing pilot (not 
available in the European Community). Please follow the instructions for your unit. 

Pilot Operation Flame Failure Gas Valve: 

Operation of the gas valve pilot: 

1. 

Turn knob on the main gas valve to the pilot position 

2. 

Depress knob to start gas flow to the pilot valve 

3. 

Light pilot valve 

a. 

Using a match or taper 

4. 

Hold in knob for 15 to 30 seconds to heat up the thermocouple 

5. 

Release knob and turn to the desired gas flow position 

a. 

If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up 

Standing Pilot Lighting Instructions:

 ( Not Available in the European Community ) 

The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first 
lighting to adjust the flame for your elevation. 

1. 

Turn off the manual shut off valve and wait 5 minutes to clear the gas. 

2. 

Turn all knobs to the "OFF" position. 

3. 

The valve can be accessed through an opening in the front panel or remove the cooking grates 
and light the pilot from above. 

4. 

Turn the manual shut off valve on. 

5.  Hold an ignition source (match) to both openings on the pilot tube. When the flames are 

established, remove the ignition source. 

6. 

Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If 
the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot 
flame should be as small as possible but large enough to guarantee reliable ignition of the burners 
when the knobs are turned to "HI". 

RELIGHTING PILOT 

If the pilot light should go out for any reason: 

 

Promptly shut off all gas at the manual shut off valve. 

 

Turn off all knobs and pilot valves; wait 5 minutes to clear gas. 

 

Relight following steps 4 through 6 under 

Standing Pilot Lighting Instructions.

 

LIGHTING MAIN BURNER: 

Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then 
adjust to any desired position between "LO" and "HI". 

 

To light burner, turn knob to "max." then back off to the desired flame level. The range of 
adjustment is virtually infinite between high and off. (At the small flame, there is a pre-set low). 

 

When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust 
from storage and shipping are burned off. An hour at "max." on all burners is usually sufficient. 

 

Turn knobs off and let cool. 

Summary of Contents for HDCB-2424i

Page 1: ...vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mainten...

Page 2: ...of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The applian...

Page 3: ...ult in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or uns...

Page 4: ...t the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Adequate clearance for air openings into the combustion chamber is required Do not place objects...

Page 5: ...1524 0 34 339 872 15 217 386 5 10 20 000 5 86 200 000 58 6 5 12 4 HDCB 2472i 72 1828 8 34 339 872 15 217 386 5 12 20 000 5 86 240 000 70 3 5 12 4 HDCRB 2424i 24 609 6 34 339 872 15 217 386 5 4 20 000...

Page 6: ...ure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or...

Page 7: ...or remove the cooking grates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remov...

Page 8: ...te the yellow tips of the burner flame Lock the air shutter in place by tightening the screws European Community If adjustment becomes necessary in the field it should be done by a factory authorized...

Page 9: ...rners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 SEASON GRIDDLE Heat to low temperature 300 350 F 150 180C and pour on a small amount...

Page 10: ...scraper H Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place WEEKLY Thoroughly clean the exposed surfaces of broiler sides front and top grease...

Page 11: ...t light out Automatic pilot valve is bad Fat appears to smoke excessively Heat is set too high Moisture in the food may be turning into steam Food sticks to grates Heat is set too high Griddle surface...

Page 12: ...12 EXPLODED VIEWS Domestic Version HDCB HDCRB GAS CHAR BROILER...

Page 13: ...NA 1 1 1 1 2 2 2 2 7 21825126 Support Firebox NA NA 1 1 21825217 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829525 Manifol...

Page 14: ...29 21825018 Guard Burner 4 6 8 11 12 30 21813129 Weldm t Grate Support 1 1 21813229 Weldm t Grate Support 1 1 21813329 Weldm t Grate Support 1 1 21825334 Weldm t Grate Support 1 1 21825434 Weldm t Gr...

Page 15: ...15 EXPLODED VIEWS CE Version HDCB HDCRB GAS CHAR BROILER...

Page 16: ...17 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829535 Manifold 24 CE 1 1 21829635 Manifold 36 CE 1 1 21829735 Manifold 48 CE...

Page 17: ...5334 Weldm t Grate Support 1 1 21825434 Weldm t Grate Support 1 1 33 3103900 Grate Cooking Hvy Dty 4 4 6 6 8 8 10 10 12 12 34 21825031 Brace Leg 2 2 2 2 2 2 2 2 2 2 35 21826134 Channel Stiffiner NA NA...

Page 18: ...HDCRB 2424i HDCB 2436i HDCRB 2436i HDCB 2448i HDCRB 2448i HDCB 2460i HDCRB 2460i HDCB 2472i HPDCRB 2472i 55 8806070 Label Delivery CE Gas Units N S 1 1 1 1 1 1 1 1 1 1 56 8806075 Label Packaging CE Un...

Page 19: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Reviews: