APW Wyott HDCB-2424i Operating Instructions Manual Download Page 4

GENERAL INSTALLATION INSTRUCTIONS 

Ensure gas supply and gas type, as shown on unit nameplate agree. 

Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National 
Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in 
accordance with local codes. 

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level 
the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, 
lift if necessary to move unit.  

Pipe threading compound must be resistant to the action of liquefied petroleum gases.  

Caution:

 DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and 

water solution before operating unit. 

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. 

Noncombustible clearances: 

0" sides (0 mm)               0" rear (0 mm)               4" floor (102mm) 

Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit 
by the flue.  

Adequate clearance for air openings into the combustion chamber is required. Do not place objects 
between the bottom of the unit and the counter top.  

There must be adequate clearance for removal of the front panel. All major parts except the burners are 
removable thru the front if the gas line is disconnected. 

Unit must have adequate clearances for servicing. (Sides = 0", Rear = 0", Floor = 4"). 

European Community Installation Instructions: 

"THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI 
REGISTERED INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO 
WORK TO SAFE AND SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN 
ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE 
RELEVANT BUILDING REGULATIONS / IEE. REGULATIONS. DETAILED RECOMMENDATIONS 
ARE CONTAINED IN THE FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172,  
BS 5440 PART 2, BS 6891" 

"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE"  

"MUST BE INSTALLED IN A WELL VENTILATED AREA. Ventilation requirements ie. B.S. 5440." 

Summary of Contents for HDCB-2424i

Page 1: ...vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mainten...

Page 2: ...of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The applian...

Page 3: ...ult in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or uns...

Page 4: ...t the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Adequate clearance for air openings into the combustion chamber is required Do not place objects...

Page 5: ...1524 0 34 339 872 15 217 386 5 10 20 000 5 86 200 000 58 6 5 12 4 HDCB 2472i 72 1828 8 34 339 872 15 217 386 5 12 20 000 5 86 240 000 70 3 5 12 4 HDCRB 2424i 24 609 6 34 339 872 15 217 386 5 4 20 000...

Page 6: ...ure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or...

Page 7: ...or remove the cooking grates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remov...

Page 8: ...te the yellow tips of the burner flame Lock the air shutter in place by tightening the screws European Community If adjustment becomes necessary in the field it should be done by a factory authorized...

Page 9: ...rners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 SEASON GRIDDLE Heat to low temperature 300 350 F 150 180C and pour on a small amount...

Page 10: ...scraper H Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place WEEKLY Thoroughly clean the exposed surfaces of broiler sides front and top grease...

Page 11: ...t light out Automatic pilot valve is bad Fat appears to smoke excessively Heat is set too high Moisture in the food may be turning into steam Food sticks to grates Heat is set too high Griddle surface...

Page 12: ...12 EXPLODED VIEWS Domestic Version HDCB HDCRB GAS CHAR BROILER...

Page 13: ...NA 1 1 1 1 2 2 2 2 7 21825126 Support Firebox NA NA 1 1 21825217 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829525 Manifol...

Page 14: ...29 21825018 Guard Burner 4 6 8 11 12 30 21813129 Weldm t Grate Support 1 1 21813229 Weldm t Grate Support 1 1 21813329 Weldm t Grate Support 1 1 21825334 Weldm t Grate Support 1 1 21825434 Weldm t Gr...

Page 15: ...15 EXPLODED VIEWS CE Version HDCB HDCRB GAS CHAR BROILER...

Page 16: ...17 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829535 Manifold 24 CE 1 1 21829635 Manifold 36 CE 1 1 21829735 Manifold 48 CE...

Page 17: ...5334 Weldm t Grate Support 1 1 21825434 Weldm t Grate Support 1 1 33 3103900 Grate Cooking Hvy Dty 4 4 6 6 8 8 10 10 12 12 34 21825031 Brace Leg 2 2 2 2 2 2 2 2 2 2 35 21826134 Channel Stiffiner NA NA...

Page 18: ...HDCRB 2424i HDCB 2436i HDCRB 2436i HDCB 2448i HDCRB 2448i HDCB 2460i HDCRB 2460i HDCB 2472i HPDCRB 2472i 55 8806070 Label Delivery CE Gas Units N S 1 1 1 1 1 1 1 1 1 1 56 8806075 Label Packaging CE Un...

Page 19: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Reviews: