APW Wyott HDCB-2424i Operating Instructions Manual Download Page 1

INSTALLATION

 

AND

 

OPERATING

 

INSTRUCTIONS

 

 

 

Heavy Duty Gas Char-Broilers 

MODELS:

  HDCB-2424i, HDCB-2436i, HDCB-2448i, HDCB-2460i, HDCB-2472i 

Heavy Duty Charrock Gas Broilers 

MODELS:

 HDCRB-2424i, HDCRB-2436i, HDCRB-2448i, HDCRB-2460i, HDCRB-2472i 

IMPORTANT FOR FUTURE REFERENCE 

 

Please complete this information and retain this manual for the life of the equipment. For 
Warranty Service and/or Parts, this information is required. 

 

 

Model Number 

 

Serial Number 

 

Date Purchased 

 

 

 

FOR YOUR SAFETY: 

Do not store or use gasoline or other flammable vapors or 

liquids in the vicinity of this or any other appliance. 

 

 

 

WARNING:

 Improper installation, adjustment, alteration, service or maintenance 

can cause property damage, injury or death. Read the installation, operating and 
maintenance instructions thoroughly before installing, or servicing this equipment. 

 

 

WARNING:

 Instructions must be posted in a prominent location. All safety 

precautions must be taken in the event the user smells gas. Safety information 
can be obtained from your local gas supplier. 

 

 

 

P/N 8822211  09/26/13

 

APW Wyott MANUFACTURING 

DALLAS: CHEYENNE: 
1307 N. Watters Rd #180 

 Allen, TX 

 75013 

1938 Wyott Dr 

 Cheyenne, WY 

 82007 

Local: (972) 908-6100 

Local: (307) 634-5801 

Toll Free: (800) 431-2745 

Toll Free: (800) 752-0863 

Parts/Service Fax: (214) 565-0976 

Parts/Service Fax: (214) 565-0976 

Summary of Contents for HDCB-2424i

Page 1: ...vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mainten...

Page 2: ...of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The applian...

Page 3: ...ult in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or uns...

Page 4: ...t the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Adequate clearance for air openings into the combustion chamber is required Do not place objects...

Page 5: ...1524 0 34 339 872 15 217 386 5 10 20 000 5 86 200 000 58 6 5 12 4 HDCB 2472i 72 1828 8 34 339 872 15 217 386 5 12 20 000 5 86 240 000 70 3 5 12 4 HDCRB 2424i 24 609 6 34 339 872 15 217 386 5 4 20 000...

Page 6: ...ure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or...

Page 7: ...or remove the cooking grates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remov...

Page 8: ...te the yellow tips of the burner flame Lock the air shutter in place by tightening the screws European Community If adjustment becomes necessary in the field it should be done by a factory authorized...

Page 9: ...rners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 SEASON GRIDDLE Heat to low temperature 300 350 F 150 180C and pour on a small amount...

Page 10: ...scraper H Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place WEEKLY Thoroughly clean the exposed surfaces of broiler sides front and top grease...

Page 11: ...t light out Automatic pilot valve is bad Fat appears to smoke excessively Heat is set too high Moisture in the food may be turning into steam Food sticks to grates Heat is set too high Griddle surface...

Page 12: ...12 EXPLODED VIEWS Domestic Version HDCB HDCRB GAS CHAR BROILER...

Page 13: ...NA 1 1 1 1 2 2 2 2 7 21825126 Support Firebox NA NA 1 1 21825217 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829525 Manifol...

Page 14: ...29 21825018 Guard Burner 4 6 8 11 12 30 21813129 Weldm t Grate Support 1 1 21813229 Weldm t Grate Support 1 1 21813329 Weldm t Grate Support 1 1 21825334 Weldm t Grate Support 1 1 21825434 Weldm t Gr...

Page 15: ...15 EXPLODED VIEWS CE Version HDCB HDCRB GAS CHAR BROILER...

Page 16: ...17 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829535 Manifold 24 CE 1 1 21829635 Manifold 36 CE 1 1 21829735 Manifold 48 CE...

Page 17: ...5334 Weldm t Grate Support 1 1 21825434 Weldm t Grate Support 1 1 33 3103900 Grate Cooking Hvy Dty 4 4 6 6 8 8 10 10 12 12 34 21825031 Brace Leg 2 2 2 2 2 2 2 2 2 2 35 21826134 Channel Stiffiner NA NA...

Page 18: ...HDCRB 2424i HDCB 2436i HDCRB 2436i HDCB 2448i HDCRB 2448i HDCB 2460i HDCRB 2460i HDCB 2472i HPDCRB 2472i 55 8806070 Label Delivery CE Gas Units N S 1 1 1 1 1 1 1 1 1 1 56 8806075 Label Packaging CE Un...

Page 19: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...