APW Wyott Series Gas Griddles

3

EXHAUST CANOPY

It is essential that facilities be provided over the griddle to carry off fumes and gases. However, 

the unit should not be directly connected to a flue or stack.

LEVELING UNIT

This griddle is supplied with (4) feet which must be screwed into the legs attached to the body. 

Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" (43.75mm) for accurate 

and perfect lineup with other units.  After the griddle is in its final position, adjust the legs to 

create 1/8 inch slant from back to front on the griddle plate.  This will allow grease to run into 

the grease gutter and provide the proper combustion air for the burners.  

DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full 

gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to 

determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads 

of the pipe joints. Such compounds shall be resistant to the action of LP gases. WARNING: Any loose 

dirt or metal particles which are allowed to enter the gas lines on this appliance will damage the valve 

and affect its operation. When installing this appliance, all pipe and fittings must be free from loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe at 

the rear of the unit. The gas supply line is then connected to it. It is shipped set for 6" (15.24cm) water 

column manifold pressure for use with natural gas.

MANUAL SHUT-OFF VALVE

A manual shut-off valve should be installed upstream from the union and within 6 feet (1.829m) of this 

appliance.

LP [PROPANE] GAS CONVERSION

This griddle is equipped with fixed orifice hoods and is shipped from the factory for use on natural gas. 

Note:  GGM & GGT units use a #47 drill orifice for natural gas and a #55 drill orifice for propane. 

To convert to propane gas, install the burner orifice hoods, located in the grease drawer, as follows:

1.  Remove front panel by removing screws located on the front and the bottom.

2.  Remove the burner(s) from the orifice hood(s).  This is accomplished by removing the burner 

mounting screw(s) and sliding the burner(s) off the hood(s).

3.  Remove natural gas orifice hood(s) and install the propane hood(s) furnished.
4.  Reinstall burner(s).

  

5.  Reinstall front panel.
6.  Remove the slotted, or hex-threaded, plug from the pressure regulator.  Invert the plug and re-install.  

The letters "LP" should now be visible on the plug.  The regulator is now set for 10" (25.4cm) water 

column.

7.  Set manifold pressure to 10" (25.4cm) water column. A 1/8" pipe plug on the supply pipe can be 

removed for attaching a pressure gauge.

CONNECTING GAS SUPPLY LINE

The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until 

the actual connection is made to the gas supply line.  

CHECKING FOR GAS LEAKS

Soap and water solution or other material acceptable for the purpose shall be used in locating gas 

leakage.  Matches,  candle  flame,  or  other  sources  of  ignition  shall  not  be  used  for  this  purpose. 

 

Check entire piping system for leaks.

CAUTION

Summary of Contents for GGM-24S

Page 1: ...e cleaning and care Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covered by this manual are also included This manual must be read and understood...

Page 2: ...ny part other than genuine APW Wyott factory supplied parts relieves the manufacturer of all liability Due to periodic changes in designs methods procedures policies and regulations the speci cations...

Page 3: ...EL NO A WIDTH Inches cm B DEPTH Inches cm C VHEIGHT Inches cm D LEG WIDTH Inches cm NO CONTROLS BTU GRID AREA INSTALLED WEIGHT lb kg SHIPPING WEIGHT lb kg GGT 24S 24 61 0 29 73 7 15 1 2 39 4 19 48 3 2...

Page 4: ...ng system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by clo...

Page 5: ...nit The gas supply line is then connected to it It is shipped set for 6 15 24cm water column manifold pressure for use with natural gas MANUAL SHUT OFF VALVE A manual shut off valve should be installe...

Page 6: ...one burner to 450 F 229 9 C 3 Close the air shutter on the front of the burner to give a soft blue flame having luminous tips and open to a point where the yellow tips disappear and a hard blue flame...

Page 7: ...e a day remove the waste drawer and wash in the same way as an ordinary cooking utensil The drawer is removed by pulling forward up and out TEMPERATURE CONTROL GGT The temperature controls are combina...

Page 8: ...6 30 35 33 30 32 31 9 REAR PANEL LEFT SIDE PANELS GGT 36S shown 23 4 4 4 26 26 26 11 16 4 18 36 29 28 27 FRONT PANEL AND CONTROLS RIGHT SIDE PANELS GGT 36S shown is a registerd trademark of APW Wyott...

Page 9: ...7 A BOTTOM 1 34 GGT 36S shown 4 14 12 35 14 23 18 6 7 10 13 17 21 2 2 8 31 31 4 4 3 19 27 20 15 14 THERMOSTAT AND BURNERS GGT 36S shown THERMOSTAT GGT MODELS ONLY is a registerd trademark of APW Wyott...

Page 10: ...REW 8 X 0 375 INCH 7 GGM 36S 59 GGM 48S 58 GGT 24S 46 GGT 36S 55 GGT 48S 58 5A LL 2P 1453 1 MANIFOLD PLUG NP 6 GGM 24S 2V 6671 2 VALVE PILOT GGM 36S 3 GGM 48S 4 GGT 24S 2 GGT 36S 3 GGT 48S 4 7 GGM 24S...

Page 11: ...GT 48S 4 13 ALL G3 Y7046 1 GREASE DRAWER 7 14 GGM 24S G3 624306 1 MANIFOLD 24 INCH WITHOUT THERMOSTAT MANUAL CONTROL 7 GGM 36S G3 624306 MANIFOLD 36 INCH WITHOUT THERMOSTAT MANUAL CONTROL GGM 48S G3 6...

Page 12: ...S 4 21 GGT 24S G3 Z4398 2 BULB CAP NP GGT 36S 3 GGT 48S 4 22 GGT 24S 2C 6517 6 NUT 1 4 20 NP GGT 36S 9 GGT 48S 12 23 ALL 2J Z0792 1 PRESSURE REGULATOR 6 7 24 GGT 24S G3 Y9531 2 INSULATOR NP GGT 36S 3...

Page 13: ...TC0102 TOP WELDMENT 36 INCH WITHOUT THERMOSTAT MANUAL CONTROL GGM 48S G4 TC0105 TOP WELDMENT 48 INCH WITHOUT THERMOSTAT MANUAL CONTROL GGT 24S G4 TC0097 TOP WELDMENT 24 INCH WITHOUT THERMOSTAT GGT 36...

Page 14: ...siness Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www apwwyott com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE COVERED UNDER WARR...

Page 15: ...PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...St Smithville TN 37166 Telephone 800 264 7827 Fax 314 781 5445 Printed in the U S A 2M Z12966 Rev 12 11 2020 Specifications are subject to change without notice is a registerd trademark of APW Wyott A...

Reviews: