Electrical Connections
Terminal Box Location:
Loading:
Fusing:
Grounding:
U.L. CONDITIONS OFACCEPTABILITY:
NOTES: .
The terminal boxes can be located at either the left front or right rear of the griddle. When shipped
from the factory the device has the terminal box attached in the left front position. The box can be
relocated to the alternate position by removing two screws.
Electrical loadings of the griddles covered by this instruction are tabulated below.
Griddle is not fused and must be connected to a properly fused circuit.
Griddle must be grounded in accordance with the National Electrical Code and applicable local
codes.
1.
This equipment must be installed in an all metal fixture of steel or stainless steel construction,
.078 inch thick minimum for the top and supporting frame. Side enclosure to be at least 22 MSG
minimum thickness.
2.
A removable bottom enclosure must be provided under each drop-in unit and be made of metal
construction of at least 22 MSG minimum. If ventilating openings are provided in the bottom
enclosure, they must not allow the entrance of ¾ inch diameter rod nor be located directly
below uninsulated live terminals.
3.
Minimum spacing between griddle top edge and adjacent items should be: fixture back wall 1 ¾
inch, fixture side enclosure 1 inch, front control panel 7/8 inch, other drop-in devices 1 inch.
4.
Controls shall be mounted on the front vertical surface of the fixture.
5.
For supply connections, use wire suitable for at least 90° C (194° F).
1.
Griddle can be mounted with the trough in the front or rear, dimensions shown are for front
trough mounting. For rear trough mounting, this dimension must be between 7/8 and 2 inches.
2.
Table top reinforcement and gasket furnished with the griddle.
3.
At the factory, the electrical connection box was installed in the front position. The connection
box can be moved to the rear location shown.
IMPORTANT:
1.
Any dimension smaller than the minimum or larger than the maximum shown in the table will
require corresponding changes to the grease chute by the fabricator by adding an extension to
prevent the grease from spilling into the cabinet.
2.
Any dimensions smaller than minimum given will require additional panels or sides and back to
facilitate servicing.
3.
The minimum dimension from the back of the control panel to the front of the griddle top is 7/8 inch
regardless of the shape of the bullnose or table overhang.
4.
Griddles are shipped from the factory with dimension "D" at 7 7/16 inch. Moveable braces permit
5