MAINTENANCE / CLEANING

WARNING: Never clean any electrical unit by immersing it in water. Turn unit off 

before cleaning surface.

Once a week or more often if necessary clean the Coldwell thoroughly. Turn off the Coldwell and 

allow it to warm.
Stainless Steel: To remove normal dirt or product residue from stainless steel, use ordinary soap and 

water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth. 

Never use vinegar or corrosive cleaners. Do not use chlorine based cleaners.
To remove grease and food splatter or condensed vapors that have baked on the equipment, apply 

cleaners to a damp cloth or sponge and rub cleanser on the metal in the direction of the polished 

lines on the metal. Rubbing cleanser as gently as possible in the direction of the polished lines will 

not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION. Soil and burnt 

deposits which do not respond to the above procedure can usually be removed by rubbing the 

surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads.

WARNING:

DO NOT USE ordinary steel wool as any particles left on the surface will rust.

NEVER USE a wire brush, steel or abrasive scouring pads (except stainless), 

scraper, file or other steel tools. Surfaces which are marred collect dirt more 

rapidly and become more difficult to clean. Marring also increases the possibility of 

corrosive attack.

NEVER use any corrosive cleaner. Use only cleaners approved for stainless steel.

NEVER use cleaning solvents with a hydrocarbon base.

GENERAL TROUBLESHOOTING

If the unit fails to operate check the following:
1.  Is the unit connected to a live power source?
2.  Check circuit breaker?
3.  Is power switch on the pilot light glowing?
4.  Check the data plate. Are you operating the unit on proper voltage?
If the above checks out and you still have problems, call an APW Wyott authorized service agency.

NOTICE: Service work should be performed only by a qualified refrigeration 

technician who is experienced in and knowledgeable with the operation of 

commercial gas, electric, steam cooking equipment. Contact the Authorized 

Service Agency for reliable service, dependable advice or other assistance and for 

genuine factory parts.

Warranty will be void and the manufacturer is relieved of all liability if:
(A)  Service work is performed by other than an APW WYOTT Authorized Service Agency. or. . .
(B)  Other than Genuine APW WYOTT replacement parts are installed.

A current listing of all authorized APW WYOTT authorized parts/service distributors is included with 

this product manual at the time of shipment. In the absence of this list you can call the APW WYOTT 

24-hour Service Hot Line which gives access to the nearest Authorized APW WYOTT parts/service 

distributor. Call 1-800-733-2203.

Summary of Contents for CTCW-43

Page 1: ...ment Company 1307 N Watters Road Suite 180 Allen TX 75013 972 908 6100 Phone 1 800 527 2100 214 565 0976 Fax www apwwyott com INSTALLATION AND OPERATING INSTRUCTIONS Counter Top Coldwell Models CTCW CTCW L CTCW43 P N 8802210 REV A 11 18 WARNING California Residents Only This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth d...

Page 2: ...o 1 or 3 phase as listed on the data plate WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment WARNING Electrical and grounding connections must comply with the applicable portions of the national electrical code and or other l...

Page 3: ...one the carrier may refuse the claim The carrier can supply the necessary forms B Concealed damage or loss if not apparent until after equipment is uncrated a request for inspection must be made to the carrier within 15 days The carrier should arrange an inspection Be certain to hold all contents and packaging material Installation and start up should be performed by a qualified installer who thor...

Page 4: ...h the national electrical code ANSI NFPA70 latest edition Canadian installation must comply with CSA STANDARD C 22 2 Number 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial Cooking Appliances NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local co...

Page 5: ...grounding could result in electrical shock This appliance is equipped with a three prong grounded plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug OPERATION Equipment Preparation Clean the Coldwell before using Wipe well and frame with a hot wet cloth to remove any sh...

Page 6: ...ollect dirt more rapidly and become more difficult to clean Marring also increases the possibility of corrosive attack NEVER use any corrosive cleaner Use only cleaners approved for stainless steel NEVER use cleaning solvents with a hydrocarbon base GENERAL TROUBLESHOOTING If the unit fails to operate check the following 1 Is the unit connected to a live power source 2 Check circuit breaker 3 Is p...

Page 7: ...y the Model Number Serial Number Part Number Description plus Finish Type of Electrical characteristics as applicable For parts not listed consult an APW Wyott Authorized Parts Distributor or APW Wyott Authorized Service Agency If necessary please consult APW Wyott Parts Department for assistance ITEM DESCRIPTION P N 1 Compressor 18071 00 2 Condenser 18014 00 3 Fan Motor 12002 00 4 Motor Bracket 1...

Page 8: ...R FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number Date Purchased Notes ...

Page 9: ...Wyott s option or its Authorized Service Agency it will be serviced on site or replaced From day two through the conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on portable units after the first day of use If the customer wants on site service they may rece...

Reviews:

Related manuals for CTCW-43