![APT 300XAC Series Quick Start Manual Download Page 5](http://html1.mh-extra.com/html/apt/300xac-series/300xac-series_quick-start-manual_2957002005.webp)
5
online
aptsources.com
Input Terminal Power Block
-
Provides input power to
the instrument.*
Output Terminal Power Block
-
Provides output power
to the DUT.
N:
Neutral output screw terminal
G:
Earth ground (chassis) connection
L:
Line output screw terminal
External Sense Output Terminal Block
-
Provides
screw terminals for external voltage sense leads.
L:
Line voltage sense screw terminal
N:
Neutral voltage sense screw terminal
Power Input Configuration
BACK PANEL CONTROLS
3
1
2
3
2a
3a
2b
3b
2c
Model 360XAC
2a
3a
2c
2b
3b
1
2
POWER INPUT
1 Ø
2 W
200-240V~
45A MAX., 47 -63Hz
200–240V~
26 A MAX., 47 – 63Hz
346–416V~
15 A MAX., 47 – 63Hz
C (T) B (S) A(R)
C (T) B (S) A(R)
L
N
N
3 Ø
3 W
3 Ø
4 W
*Model 360XAC requires 1Ø 200-240 VAC ± 10%, 3Ø3W 200-240 VAC ± 10%, 3Ø4W 346-416 VAC ± 10% at 47-63 Hz.