8.1 YC600B Microinverter Datasheet

Region

LATAM

Input Data (DC)

Recommended PV Module Power (STC) Range

300Wp-550Wp+

Peak Power Tracking Voltage

22-48V

Operation Voltage Range

16-60V

Maximum Input Voltage

60V

Maximum Input Current

12A x 2

Maximum Input Short Circuit Current

13.2A

Output Data (AC)

Maximum Output Power

750VA

Nominal Output Voltage/Range

(1)

120V/95-155V

Adjustable Output Voltage Range

90-160V

Nominal Output Current

6.26A

Nominal Output Frequency/Range

(1)

60Hz/57-62Hz

Adjustable Output Frequency Range

55.1-64.9Hz

Power Factor(Adjustable)

>0.99

Maximum Units per 12AWG Branch

(2)

4

Efficiency

Peak Efficiency

96%

Nominal MPPT Efficiency

99.5%

Night Power Consumption

20mW

Mechanical Data

Operating Ambient Temperature Range

(3)

-40

o

F to +149

o

F (-40 °C to +65 °C )

Storage Temperature Range

-40

o

F to +185

o

F (-40 °C to +85 °C )

Dimensions (W x H x D)

10.3”

×

7.4”

×

1.3” (260mm X 188mm X 31.5mm)

Weight

5.7lbs (2.6kg)

AC Bus Cable

12AWG (28A)

DC Connector Type

Stäubli MC4 PV-ADBP4-S2&ADSP4-S2

Enclosure Environmental Rating

Type 6

Cooling

Natural Convection - No Fans

Overvoltage Category

OVC II For PV Input Circuit, OVC III For Mains Circuit

Utility Interconnection Voltage And Frequency

Trip Limits And Trip Times

See NOTE 1 Below

Trip Limit And Trip

Time Accuracy

Voltage

+/-2V

Frequency

+/-0.1Hz

Alternate Trip times

See NOTE 1 Below

Features

Communication (Inverter To ECU)

(4)

Wireless

Transformer Design

High Frequency Transformers, Galvanically Isolated

Monitoring

Energy Management Analysis (EMA) system

Warranty

(5)

10 Years Standard

Certificate&Compliance

Compliance

UL1741 (IEEE1547); CSA C22.2 No. 107.1; NOM-001;

ABNT NBR 16149:2013; ABNT NBR 16150:2013;

ABNT NBR IEC 62116: 2012

Summary of Contents for YC600B

Page 1: ...erved Please scan this QR code to have access to our APPs and Products information ALTENERGY POWER SYSTEM Inc latam APsystems com APsystems APsystems Guadalajara AV Lazaro Cardenas 2850 5 Piso Colonia...

Page 2: ...9 4 3 3 Step 3 Attach the APsystems Microinverters to the racking 9 4 3 4 Step 4 Ground the systems 10 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable 10 4 3 6 Step 6 Install a Bus C...

Page 3: ...n the APsystems Microinverter system and the solar array Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80 C To reduce risk of burns do not touch...

Page 4: ...But there is no guarantee that interference will not occur in a particular installation If this equipment causes harmful interference to radio or television reception the following measures might res...

Page 5: ...uately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid hazards which electricity can create For the purpose of the safety information of thi...

Page 6: ...systems Microinverter System Introduction The APsystems Microinverter is used in utility interactive grid tied applications comprised of three key elements APsystems Microinverter APsystems Energy Com...

Page 7: ...system ensures that no single point of system failure exists across the PV system APsystems Microinverters are designed to operate at full power at ambient outdoor temperatures of up to 149 F 65 C Th...

Page 8: ...ed 375VA peak output power per channel the YC600B works with 60 and 72 cell PV modules and offers dual independent MPPT per panel The YC600B also operates within a wider MPPT voltage range than compet...

Page 9: ...ations in accordance with local electrical codes 2 Be aware that only qualified professionals should install and or replace APsystems Microinverters 3 Before installing or using an APsystems Microinve...

Page 10: ...e to partially or fully disconnect from the unit resulting in no or poor operation 4 3 3 Step 3 Attach the APsystems Microinverters to the racking a Mark the location of the Microinverter on the rack...

Page 11: ...to AC bus cable Push the microinverter AC connector into the trunk cable connector until you hear a click Try to remove it to check that it is properly locked Figure 4 Best Practice Use the Bus Cable...

Page 12: ...es Figure 9 When plugging in the DC cables the microinverter should immediately blink green three times This will happen as soon as the cables are plugged in and will show that the microinverter is fu...

Page 13: ...te installation map is required The layout map provided is designed to accomodate labels in vertical or horizontal orientation to meet all the field PV connections a Each APsystems Microinverter has r...

Page 14: ...table for general arrangement 2 Installation card is located in Appendix last page of this manual 3 You can use Scanning Gun or mobile phone to scan the serial numbers on the map when set ECU see ECU...

Page 15: ...aker This means they are producing power normally but have not yet connected to the ECU After the ECU has been plugged in setup acknowledges the Microinverters they will start to blink green every 10...

Page 16: ...rupter GFDI error in the PV system Unless the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault After the ground fault error is fixed follow the instruction...

Page 17: ...oordinating with data displays from other units most likely a Microinverter problem To troubleshoot a non operating APsystems Microinverter Follow the steps below in order 1 Verify the utility voltage...

Page 18: ...sconnect the inverter AC connector from the AC Bus 3 Disconnect the PV module DC wire connectors from the microinverter 4 Remove the Microinverter from the PV array racking B Install a replacement Mic...

Page 19: ...verter Please refer to the datasheet or usermanual which can be download from APsystems website www APsystems com 2 You must match the DC operating voltage range of the PV module with the allowable in...

Page 20: ...g Ambient Temperature Range 3 40 o F to 149 o F 40 C to 65 C Storage Temperature Range 40 o F to 185 o F 40 C to 85 C Dimensions W x H x D 10 3 7 4 1 3 260mm X 188mm X 31 5mm Weight 5 7lbs 2 6kg AC Bu...

Page 21: ...f 59 3 160ms 200ms 2022 06 29 REV1 5 1 Nominal voltage frequency range can be extended beyond nominal if required by the utility 2 Limits may vary Refer to local requirements to define the number of m...

Page 22: ...Apsystems YC600B ENERGY COMMUNICATION UNIT ECU SOLAR PANEL BUS CABLE END CAP INSTALL AT THE END OF AC BUS CABLE AC JUNCTION BOX DISTRIBUTION PANEL BROWN L BLUE N YELLOW GREEN PE 9 Wiring Diagram 9 1...

Page 23: ...r in your PV installation Each APsystems microinverter has two serial number labels Peel the one label and affix it to the respective location on the APsystems installation map Installation Map Templa...

Reviews: