APsystems Microinverter DS3 series Installation manual

16

6. Troubleshooting

Qualified personnel can use the following troubleshooting steps if the PV system does not operate correctly:

6.1 Status Indications and Error Reporting

Assuming they are easily accessible and visible, Operation LEDs can give a good indication of the microinverters
status

6.1.1 Start up LED

Ten short green blinks when DC power is first applied to the Microinverter indicates a successful
Microinverter startup.

6.1.2 Operation LED

Flashing Slow Green (5 sec. gap)

- Producing power and communicating with ECU

Flashing Slow Red (5 sec. gap)

- Not producing power

Flashing Fast Green (2 sec. gap) -

Not communicating with ECU over 60mins, but still producing power.

Flashing Fast Red (2 sec. gap) -

Not communicating with ECU over 60mins and not producing power.

Steady Red

– default, DC side ground fault protection, see 6.1.3

6.1.3 GFDI Error

A solid red LED indicates the Microinverter has detected a Ground Fault Detector Interrupter (GFDI) error in
the PV system. Unless the GFDI error has been cleared, the LED will remain red and the ECU will keep
reporting the fault. Please contact your local APsystems Technical Support.

6.2 ECU_APP

APsystems ECU_APP (available in the EMA Manager APP) is the recommended tool to do on-site troubleshooting.
When connecting the ECU_APP to the ECU hotspot (please check ECU User Manual for more detailed
information), installer can check every microinverter status (production, communication) but also ZigBee signal
strength, grid profile and other insightful data helping the troubleshooting.

6.3 Installer EMA (web portal or EMA Manager APP)

Before going on site for troubleshooting, installer can also check all information remotely using his installer
account, either on the web or using the EMA Manager APP (see EMA Manager APP User Manual for more
detailed information). Having access to module data (DC, AC, voltages and currents) gives the first indication on
potential issues.

6.4 Trouble Shooting Guide

Professional installers can also refer to our Troubleshooting Guide

(

https://emea.apsystems.com/resources/library/

, section libraries)for more in depth guidelines on how to

troubleshoot and fix PV installations powered by APsystems microinverters.

Summary of Contents for DS3 Series

Page 1: ...3 H Microinverters For EMEA APsystems Microinverter Installation manual All Rights Reserved ALTENERGY POWER SYSTEM Inc emea APsystems com APsystems Karspeldreef 8 1101 CJ Amsterdam The Netherlands EMAIL info emea APsystems com APsystems 244c rue du Point du Jour 01000 Saint Denis lès Bourg France EMAIL info emea APsystems com ...

Page 2: ...10 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable 10 4 3 6 Step 6 Install a Bus Cable End Cap at the end of AC bus cable 11 4 3 7 Step 7 Connect APsystems Microinverters to the PV Modules 12 4 3 8 Step 8 Connect APsystems Microinverters to Grid 13 4 3 9 Step 9 AC Extension Cable 13 4 3 10 Step 10 Complete the APsystems installation map 14 4 3 11 Step 11 Warning Notice 14 5 APsyst...

Page 3: ... Before installing or using the APsystems Microinverter please read all instructions and cautionary markings in the technical documents and on the APsystems Microinverter system and the solar array Do NOT disconnect the PV module from the APsystems Microinverter without first disconnecting the AC power Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperatu...

Page 4: ...nst harmful interference in a residential installation Nonetheless if the Microinverter does cause harmful interference to radio or television reception you are encouraged to try to correct the interferences by one of more of the following measures A Reorient or relocate the receiving antenna B Increase the separation between the Microinverter and the receiver C Connect the Microinverter into an o...

Page 5: ...cerning the decommissioning of equipment CE mark is attached to the solar inverter to verify that the unit follows the provisions of the European Low Voltage and EMC Directives Refer to the operating instructions Qualified personnel Person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid hazards which electricity can create For ...

Page 6: ...verter is used in utility interactive grid tied applications comprised of three key elements APsystems Microinverter APsystems Energy Communication Unit ECU APsystems Energy Monitor and Analysis EMA web based monitoring and analysis system Figure 1 AC JUNCTION BOX DISTRIBUTION PANEL ENERGY COMMUNICATION UNIT ECU Internet EMA ...

Page 7: ...erter ensures top performance from the array by maximizing the performance of each module individually within the array More reliable than centralized or string inverters The distributed APsystems Microinverter system ensures that no single point of system failure exists across the PV system APsystems Microinverters are designed to operate at full power at ambient outdoor temperatures of up to 65 ...

Page 8: ...ion enhance waterproof properties and ensure maximum reliability of the system via rigorous testing methods including accelerated life testing A 24 7 energy access through apps or web based portal facilitate remote diagnosis and maintenance The new DS3 series is interactive with power grids through a feature referred to as RPC Reactive Power Control to better manage photovoltaic power spikes in th...

Page 9: ...g an APsystems Microinverter please read all instructions and warnings in the technical documents and on the APsystems Microinverter system itself as well as on the PV array Be aware that installation of this equipment includes the risk of electric shock Do not touch any live parts in the system including the PV array when the system has been connected to the electrical grid Even if not required b...

Page 10: ...ered by the warranty Do NOT carry the microinverter by the AC cable This may cause the AC cable to partially or fully disconnect from the unit resulting in no or poor operation 4 3 3 Step 3 Attach the APsystems Microinverters to the Racking a Mark the location of the microinverter on the rack with respect to the PV module junction box or any other obstructions b Mount one microinverter at each of ...

Page 11: ...n areas with special grounding requirements external grounding work may still be needed using the grounding lug supplied with the Microinverter Figure 3 4 3 5 Step 5 Connect the APsystems microinverter to AC bus cable Insert the microinverter AC connector into the trunk cable connector Make sure to hear the click as a proof of robust connection Figure 4 Best Practice Use the AC Bus Cable Unlock To...

Page 12: ...from left to right Figure 6 Cover any unused connectors with Bus Cable Y CONN Cap to protect the unused connectors Figure 7 4 3 6 Step 6 Install a Bus Cable End Cap at the end of AC bus cable Figure 8 A Strip cable jacket B Insert the cable end into the seal C Rotate the nut with 3 3N m until the latching mechanism meets the base ...

Page 13: ...is entire check function will start and end within 10 seconds of plugging in the unit so pay careful attention to these lights when connecting the DC cables Double check to make sure all of the AC and DC wiring has been correctly installed Ensure that none of the AC and or DC wires are pinched or damaged Make sure that all of the junction boxes are properly closed Figure 10 Each PV panel must be c...

Page 14: ...g to the local regulation which are mandatory to connect to grid Leakage current breakers or AFCI GFCI breakers are not recommended to install 4 3 9 Step 9 AC Extension Cable Figure 12 When AC extension cable is needed users could connect the AC bus cable and AC extension cable in a junction box or use a pair of male female AC connectors that APsystems provides as optional accessory AC Extension C...

Page 15: ... is available in the last page appendix of this manual Use ECU_APP available in the EMA Manager to scan the serial numbers on the map when setting up the ECU see ECU instruction manual for more info 4 3 11 Step 11 Warning Notice A warning notice must be placed in such a way that anyone with access to live parts is warned in advance of the need to switch off these parts It is imperative to verify t...

Page 16: ... producing power after approximately one minute of waiting time 3 Microinverter data will be available in the EMA Manager APP or in the EMA web portal Alternatively LED sequences could be an indicator of microinverters status see section 6 1 Once the ECU has been commissioned properly the APsystems Microinverters will start to send performance data to the ECU The time required for all of the Micro...

Page 17: ...ystem Unless the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault Please contact your local APsystems Technical Support 6 2 ECU_APP APsystems ECU_APP available in the EMA Manager APP is the recommended tool to do on site troubleshooting When connecting the ECU_APP to the ECU hotspot please check ECU User Manual for more detailed information installer ca...

Page 18: ...stems Technical Support Never disconnect the DC wire connectors under load Ensure that no current is flowing in the DC wires prior to disconnecting Always disconnect AC power before disconnecting the PV module wires from the APsystems Microinverter The APsystems Microinverter is powered by PV module DC power AFTER disconnecting the DC power when reconnecting the PV modules to the Microinverter be ...

Page 19: ...e PV module DC wire connectors from the microinverter 4 Remove the Microinverter from the PV array racking B Install a replacement Microinverter to the rack Remember to observe the flashing green LED light as soon as the new Microinverter is plugged into the DC cables C Connect the AC cable of the replacement Microinverter to the AC bus D Close the branch circuit breaker and verify proper operatio...

Page 20: ...ons of your PV module are compatible with the range allowed on APsystems Microinverter Please check the microinverter datasheet DC operating voltage range of the PV module must be within allowable input voltage range of the APsystems Microinverter The maximum open circuit voltage of the PV module must not exceed the specified maximum input voltage of the APsystems 2022 11 03 Rev1 1 ...

Page 21: ...anual 20 9 DS3 series Wiring Diagram 9 1 Sample Wiring Diagram Single Phase Figure 14 DS3 ENERGY COMMUNICATION UNIT ECU SOLAR PANEL BUS CABLE END CAP INSTALL AT THE END OF AC BUS CABLE AC JUNCTION BOX DISTRIBUTION PANEL BROWN L BLUE N YELLOW GREEN PE ...

Page 22: ... your PV installation Each APsystems microinverter has two serial number labels Peel the one label and affix it to the respective location on the APsystems installation map Installation Map Template Installer PV module type Qty Sheet___of____ Owner Microinverter type Qty Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 Row 1 Row 2 Row 3 Row 4 Row 5 Row6 Row 7 Row 8 Row 9 Row10 s N ...

Reviews: