background image

6.2 SUBSEQUENT PROGRAMMING

To program other remote controls in a second time, 

turn the module off and on

 

or wait the end of a close cycle

 (end 

of the operating time), then proceed as follows.

1.  Press keys 1-4-5-8 simultaneously (TR14) or press all keys when using an 

already programmed 

TR2 or 

a TR4, until a short beep followed by a continuous sound is emitted signalling that the learning phase 
is in progress.

2.  Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or TR4) of the 

new remote control to be programmed

until the buzzer turns off for a short time before turning on again.

3.  Now press any key of the 

new remote control to be programmed

 until the buzzer turns off for a short time 

before turning on again.

Even in this case, it is possible to program more remote controls by repeating steps 2 and 3 until the sound 
alarm remains activated.

The learning phase ends by pressing the clear key SW3 or automatically about 25 after the last storage. 

6.3 CLEARING A REMOTE CONTROL

1.  With the module turned on, press continously SW3: the buzzer will turn on with a continuous sound.

2.  While holding SW3, press any key of the remote control to be erased. The buzzer will turn off shortly confi rming 

that the remote control has been cleared.

To clear more remote controls, repeat step 2 while holding SW3.

7. ACCESS CONTROL MANAGEMENT

The Aprimatic remote controls are supplied already programmed with a 

unique serial number

.

Without programming interventions after the purchase by installers equipped with the Aprimatic special tools, access 
control operations can be directly managed by programming the fi rst remote control. This standard mode guarantees 

maximum safety conditions (hopping rolling code) 

for any type of installation.

Access operations can also be managed in other 3 modes with different functional and safety characteristics. These 
3 modes have to be programmed by qualifi ed installers equipped with the special Aprimatic 

programming tools

Apricot Manager Coding Unit and/or Software

.

8. OPERATION LOGIC SELECTION

The operation logic of the automation is set by means of jumpers JP1 and JP2. The position of jumpers JP3 
and JP4 is negligible.

Manual

 - JP1 and JP2 open: 

The automation opens (or closes) until the relevant local control is operated; if the control is 
released or two commands are given simultaneously, the motion stops.

Semiautomatic Open/Close

 - JP1 closed, JP2 open.

Local Open command 

moves the automation open for the duration of the operating time. When 

the opening manoeuvre is completed, the automation stops waiting for a 

Local Close command 

that will move the automation close for the duration of the operating time. During motion, an open 
or close command will stop the automation (partial opening and/or closing).

Semiautomatic step-by-step

 - JP1 open, JP2 closed.

In this logic, only the 

Local Open command 

is activated through which both opening and closing 

motions are controlled. When the opening manoeuvre is completed (operating time elapsed), the 
automation stops and waits for a new command. During motion, a new command will stop the 
automation (partial opening and/or closing).

Automatic

 - JP1 and JP2 closed.

In this logic, only the 

Local Open command 

is activated through which the opening motion is 

controlled. When the opening manoeuvre is completed (say at the end of the working time), the 
automation stops, pauses for the pre-set time and then closes. During the closing cycle, a new 
command will reverse the motion of the automation.

Caution

The intervention of a safety device during the closing phase reverses the motion of the automation regardless of the 
operation logic selected, but for the “Manual” logic, in which it stops the automation opening or closing.

Information

After any modifications of the configuration of jumpers JP1 and JP2, turn the module off and on again to 
re-program the microprocessor

Summary of Contents for M230S

Page 1: ...on écrite de Aprimatic S p A Les caractéristiques du produit peuvent être soumises à modifications sans préavis Le présent document peut de ce fait ne pas correspondre exactement aux caractéristiques du produit Licences et marques Le logotype Aprimatic est une marque déposée de Aprimatic S p A Imprimé en Italie APRIMATIC S p A 2002 Alle Rechte vorbehalten Kein Teil dieses Handbuchs darf ohne schri...

Page 2: ...s it is important to read this manual carefully strictly observing the instructions given ZWECK DES HANDBUCHS Dieses Handbuch wurde vom Hersteller verfasst und ist wesentlicher Bestandteil des Produkts Die darin enthaltenen Informationen richten sich an erfahrenes Montage und Wartungspersonal Die Beachtung der Anweisungen gewährleistet Sicherheit wirtschaftlichen Betrieb der Anlage und lange Leben...

Page 3: ...a messa a terra dell attuatore deve essere eseguita esternamente all apparecchiatura stessa Proteggere l apparecchiatura e il motore collegato con interruttore magnetotermico differenziale di taglia adeguata con soglia di intervento differenziale 30 mA Al termine dell installazione verificare sempre il corretto funzionamento dell apparecchiatura e dell automazione nel suo complesso Tenere i bambin...

Page 4: ...uire la seguente procedura di cancellazione Togliere alimentazione al modulo Rialimentare il modulo tenendo premuto il tasto di cancellazione SW3 fino allo spegnimento del buzzer Attendere circa 10 secondi l emissione di un beep che segnala l avvenuta cancellazione 6 GESTIONE DEI TELECOMANDI 6 1 PRIMA MEMORIZZAZIONE Dopo aver alimentato il modulo attendere che l apparecchiatura emetta un beep ed e...

Page 5: ... sicurezza differenti la programmazione di queste ulteriori 3 modalità può essere effettuata solo da installatori in possesso degli speciali tools di programmazione Aprimatic Codificatore e o Software per gestione accessi Apricot Manager 8 SELEZIONE LOGICA DI FUNZIONAMENTO La logica di funzionamento dell automazione viene impostata tramite i jumper JP1 e JP2 La posizione dei jumper JP3 e JP4 è irr...

Page 6: ...TR14 oppure tutti i tasti nel caso di un TR2 o di un TR4 10 PROGRAMMAZIONE DEI TEMPI Tale programmazione può essere eseguita solo dopo aver tolto e ridato tensione all apparecchiatura oppure al termine di un ciclo di chiusura attendere lo scadere del tempo di lavoro In configurazione standard il tempo di lavoro e il tempo di pausa sono pari a 45 secondi Queste impostazioni sono accettabili nella g...

Page 7: ... durata del tempo di lavoro impostato In ogni caso gli ingressi di Stop e sicurezza restano attivi garantendo così la possibilità di interrompere o invertire il moto in presenza di pericoli a cose o persone Esempio 1 controllo singolo e multiplo di due automazioni con un solo telecomando a 4 tasti Selezionare per entrambi i moduli la logica passo passo con le seguenti assegnazioni per i comandi vi...

Page 8: ...operator must be connected to a separate ground system with efficient plates Protect the appliance and the connected motor with a thermal switch of suitable size with a current balancing threshold of 30 mA After the installation check the correct functioning of the appliance and the controlled automation Keep children clear of the working range of the automation during operation do not allow child...

Page 9: ...stored in the module memory proceed as follows Turn off the module Turn the module on again while holding the clear key SW3 pressed until the buzzer will turn off Wait about 10 seconds until the module beeps once signalling that the clearing phase is completed 6 REMOTE CONTROLS MANAGEMENT 6 1 FIRST PROGRAMMING Turn on the module and wait until it beeps once then 1 Press keys 1 4 5 8 simultaneously...

Page 10: ...fety characteristics These 3 modes have to be programmed by qualified installers equipped with the special Aprimatic programming tools Apricot Manager Coding Unit and or Software 8 OPERATION LOGIC SELECTION The operation logic of the automation is set by means of jumpers JP1 and JP2 The position of jumpers JP3 and JP4 is negligible Manual JP1 and JP2 open The automation opens or closes until the r...

Page 11: ...remember that you have to press again keys 1 4 5 8 TR14 or all keys TR2 or TR4 to skip a key position 10 TIMES PROGRAMMING This programming can be done only after having turned the appliance off and on or at the end of a closing cycle end of the operating time In standard configuration operating time and pause time are 45 seconds These parameters satisfy most applications if they have to be change...

Page 12: ... closing cycle controlled by a centralized commands local commands are disabled Regardless of the operation logic selected the reception of a centralized command causes the immediate execution of the corresponding motion for the duration of the pre set operating time Stop and Safety inputs remain always activated thus enabling the user to stop or reverse the motion in the event of dangers for peop...

Page 13: ...a terre de l automatisme devra être effectuée à l extérieur de l unité Protéger l unité et le moteur relié avec un interrupteur magnétothermique différentiel de dimensions adaptées avec un seuil d intervention différentielle de 30 mA Après l installation vérifier toujours le fonctionnement de l unité et de l ensemble de l automatisme Garder les enfants hors du rayon d action de l automatisme lorsq...

Page 14: ...dule en maintenant la touche d effacement SW3 enfoncée jusqu à ce que le vibreur sonore s éteigne Attendre environ 10 secondes jusqu à l émission d un bip sonore signalant que l effacement a été effectué 6 GESTION DES TÉLÉCOMMANDES 6 1 PREMIÈRE MÉMORISATION Mettre sous tension le module et attendre jusqu à ce que l unité émette un bip sonore puis procéder comme suit 1 Presser simultanément les tou...

Page 15: ...odalités ultérieures peut être effectuée uniquement par des installateurs possédant les utilitaires spéciaux de programmation Aprimatic Codeur et ou Logiciel pour la gestion des accès Apricot Manager 8 SÉLECTION LOGIQUE DE FONCTIONNEMENT La logique de fonctionnement de l automatisme est paramétrée avec les cavaliers JP1 et JP2 La position des cavaliers JP3 et JP4 est négligeable Homme Présent JP1 ...

Page 16: ...touches 1 4 5 8 TR14 ou toutes les touches TR2 ou TR4 10 PROGRAMMATION DES TEMPS Cette programmation peut être effectuée seulement après avoir mis hors puis sous tension l unité de commande ou à la fin d un cycle de fermeture attendre la fin du temps de travail En configuration standard le temps de travail et le temps de pause sont de 45 secondes Ces valeurs sont acceptables dans la plupart des ca...

Page 17: ...roduite Dans tous les cas les entrées Arrêt et Sécurité restent activées offrant de cette façon la possibilité d interrompre ou d inverser le mouvement lors d un danger pour les personnes ou les choses Exemple 1 contrôle individuel et multiple de deux automatismes avec une seule télécommande à 4 touches Sélectionner pour les deux modules la logique pas à pas avec les assignations suivantes pour le...

Page 18: ...en Die Steuerung besitzt keine Klemmen für den Erdanschluss Die Erdung des Antriebs muss außerhalb der Steuerung erfolgen Die Steuerung und den angeschlossenen Motor durch einen Differenzial Thermomagnetschalter von angemessener Größe und mit einer Schaltdifferenz von 30 mA schützen Am Ende der Installation immer das einwandfreie Funktionieren der Steuerung und der Automatik im Ganzen überprüfen K...

Page 19: ...prozedur durchgeführt werden Den Modul vom Stromnetz abschalten Den Modul wieder einschalten dabei die Löschtaste SW3 so lange drücken bis sich der Summer ausschaltet Rund 10 Sekunden warten bis ein Piepton die erfolgte Löschung anzeigt 6 VERWALTUNG DER FERNSTEUERUNGEN 6 1 ERSTSPEICHERUNG Nach Versorgen des Moduls warten bis die Steuerung einen Piepton hören lässt dann folgende Prozedur ausführen ...

Page 20: ...ierung dieser 3 weiteren Modalitäten kann nur von einem Monteur vorgenommen werden der im Besitz der speziellen Aprimatic Programmierungstools ist Kodierer und oder Software für Zugangskontrolle Apricot Manager 8 WAHL DER BETRIEBSLOGIK Die Betriebslogik der Automatik wird mit den Jumpern JP1 und JP2 eingestellt Die Position der Jumper JP3 und JP4 ist ohne Einfluss Totmann JP1 und JP2 offen Die Aut...

Page 21: ...e Tasten 1 4 5 8 bei TR14 oder alle Tasten bei TR2 oder TR4 gedrückt werden müssen 10 PROGRAMMIERUNG DER ZEITEN Diese Programmierung kann erst durchgeführt werden nachdem die Steuerung aus und wieder eingeschaltet wurde oder am Ende eines Schließungszyklus warten bis die Arbeitszeit abgelaufen ist In der Standardkonfiguration sind die Arbeitszeit und die Pausenzeit je 45 Sekunden Diese Einstellung...

Page 22: ...zeln und in Gruppen mit derselben Fernsteuerung Die zentralen Befehle haben Vorrang vor den lokalen Befehlen Das bedeutet dass die lokalen Befehle mindestens für die gesamte Dauer des von einem zentralen Signal gesteuerten Zyklus Öffnung oder Schließung gesperrt sind Außerdem bleiben die lokalen Befehle solange ein zentraler Befehl vorliegt bis zu dessen Deaktivierung gesperrt Unabhängig davon wel...

Page 23: ...ión de tierra la toma de tierra del actuador deberá efectuarse en el exterior del mismo equipo Proteja el equipo y el motor conectado con un interruptor termomagnético diferencial de potencia adecuada y umbral de intervención diferencial de 30 mA Al finalizar la instalación compruebe siempre el funcionamiento correcto del equipo y de la automatización en general Tenga los niños fuera del rayo de a...

Page 24: ...éngase al siguiente procedimiento de cancelación Quite tensión al módulo Vuelva a dar tensión al módulo manteniendo la tecla de cancelación SW3 hasta el apagado del buzzer Espere unos 10 segundos hasta la emisión de un bip que señala la cancelación 6 GESTIÓN DE LOS TELEMANDOS 6 1 PRIMERA MEMORIZACIÓN Después de dar tensión al módulo espere que el equipo emita un bip y efectúe el siguiente procedim...

Page 25: ... la programación de estas 3 ulteriores modalidades puede ser confiada únicamente a instaladores provistos de los tools especiales de programación Aprimatic Codificador y o Software para gestión accesos Apricot Manager 8 SELECCIÓN LÓGICA DE FUNCIONAMIENTO La lógica de funcionamiento de la automatización se introduce mediante los jumpers JP1 y JP2 La posición de los jumpers JP3 y JP4 es insignifican...

Page 26: ...las 1 4 5 8 TR14 o todas las teclas TR2 o TR4 10 PROGRAMACIÓN DE LOS TIEMPOS Esta programación puede efectuarse sólo después de haber quitado y dado de nuevo tensión al equipo o al final de un ciclo de cierre es decir al final del tiempo de trabajo En configuración estándar el tiempo de trabajo y el tiempo de pausa son 45 segundos Estos parámetros son aceptables en la mayoría de los casos si fuera...

Page 27: ...n del tiempo de trabajo introducida En todo caso las entradas de Stop y Seguridad permanecen activadas garantizando así la posibilidad de interrumpir o invertir el movimiento en presencia de peligros para personas o cosas Ejemplo 1 control sencillo y múltiplo de dos dispositivos de automatización mediante un solo telemando de 4 teclas Seleccione para los módulos la lógica paso a paso con las sigui...

Page 28: ......