MAINTENANCE
CLEAN OR REPLACE THE AIR FILTER
After initial installation the air filter should be checked and cleaned every 6 months. The CLEAN FILTER
service reminder will display on the on-board control screen every 6 months. To clear the service
message, press the UP and DOWN arrows simultaneously for 3 seconds.
FILTER CLEANING PROCEDURE
1.
Turn the ON/OFF switch OFF.
2.
Remove the filter access door from either side of the dehumidifier.
3.
Slide the filter out of the dehumidifier.
4.
Flush the filter with warm water and a mild detergent solution.
5.
Shake off the excess water from the filter.
6.
When inserting the filter, make sure the filter is secured in the top and bottom rails. Safety clips are located along the filter frame and will
compress within the filter frame as the filter is installed. If the filter doesn’t insert completely check for presence and proper placement of the
drain insert (see page 6).
7.
Replace the filter access door.
8.
Turn the ON/OFF switch ON.
9.
Press the UP and DOWN buttons simultaneously for 3 seconds to clear the service message.
90-1854
5