background image

SETTING THE DESIRED HUMIDITY LEVEL

The dehumidifier can be set up to control based on dew point or relative humidity (%RH).

The dehumidifier on-board control will display the dryness setting 
when not running, and displays the measured humidity when running.

The UP and DOWN arrow buttons allow the dryness setting to be set 
from 1 to 7. Use the ON/OFF button to turn the dehumidifier ON or OFF.

Set the control at 3 for initial operation. This setting and corresponding 
dew point is recommended for preservation and preventing 
condensation on floor joists. Allow the dehumidifier to run until it 
reaches the setting before deciding if you want to change the setting.

•   If you prefer the air to be more dry,

 increase the dryness level.

•   If you prefer the air to be less dry,

 decrease the dryness level.

See 

Table 1

 for dryness settings and corresponding dew point (DP).

90-1853

DEW POINT CONTROL

HUMIDITY CONTROL

TABLE 1 – %RH (+/- 5%) Based on Dryness Setting and 
Crawl Space Temperature

Dryness Setting  
& Dew Point

Crawl Space Temperature

60°F

65°F

70°F

1 – Less, 65°F DP

84%

2 – 61°F DP

86%

73%

3 – Normal, 57°F DP

88%

74%

63%

4 – Normal, 53°F DP

76%

64%

54%

5 – Normal, 49°F DP

65%

55%

46%

6 – 46°F DP

55%

47%

39%

7 – Most Dry, 42°F DP

47%

40%

34%

EXAMPLE:

 At a crawl space temperature of 

70°F

 and a dryness level 

setting of 

3 (57°F DP)

, the dehumidifier will work to achieve a 

63%

 

relative humidity level.

•  The %RH values are +/- 5% and are to be used as a GUIDE ONLY.

•  The crawl space temperature is measured at the dehumidifier inlet.

The dehumidifier on-board control will display the humidity setting when not running, 
and displays the measured humidity when running.

The UP and DOWN arrow buttons allow the humidity level to be set from 40% to 80% 
relative humidity. Use the ON/OFF button to turn the dehumidifier ON or OFF.

Set the control at 55%RH when first 
installed. Allow the dehumidifier to run 
until it reaches the setting before deciding 
if you want to change the setting.

•   If you prefer the air to be more dry,

 

decrease the humidity setting.

•   If you prefer the air to be less dry,

 

increase the humidity setting.

Your comfort is the best measure of how to adjust your setting. When first installed, 
your dehumidifier has to remove all the moisture that is initially in your home. The home 
acts like a sponge so the moisture in the materials of your home is at the same level as 
the air. After drying the air, the materials of the home will release moisture back into 
the air until they are again at the same level. As a result, it is not uncommon for the 
dehumidifier to operate for an extended period when first installed.

ENERGY SAVINGS TIPS 

Energy Savings Tip #1:

 Adjust the humidity 

setting to be as high as is comfortable to 
reduce dehumidifier run time. If it feels 
clammy or “smells musty”, lower the humidity 
setting. To save energy, turn the dehumidifier 
to OFF when you open your windows, just as 
you would with air conditioning. 

Energy Savings Tip #2:

 If vacating your home 

for an extended period in the summer, set the 
RH at 55% and set your thermostat as high as 
you are comfortable setting it to in the cooling 
mode. Consult with appropriate professionals 
regarding the highest temperature that is safe 
for your pets or possessions. This will keep the 
humidity at a controlled level while minimizing 
the amount of cooling energy used.

90-1853

3

Summary of Contents for E080CS

Page 1: ...INSTALLED BY INSTALLER PHONE DATE INSTALLED PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER TABLE OF CONTENTS PRINCIPLES OF DEHUMIDIFICATION 2 SETTING THE DESIRED HUMIDITY LEVEL 3 Dew Point Control 3 Hum...

Page 2: ...t colder than the dew point of the incoming air The dew point is the temperature at which moisture in the air will condense much like what occurs on the outside of a cold glass on a hot summer day The...

Page 3: ...n not running and displays the measured humidity when running The UP and DOWN arrow buttons allow the humidity level to be set from 40 to 80 relative humidity Use the ON OFF button to turn the dehumid...

Page 4: ...will display DEHUMIDIFYING along with the measured humidity on the control screen Model 76 Control 90 1854 90 1854 Once per hour the dehumidifier will measure the humidity level of the air and compare...

Page 5: ...er 3 Slide the filter out of the dehumidifier 4 Flush the filter with warm water and a mild detergent solution 5 Shake off the excess water from the filter 6 When inserting the filter make sure the fi...

Page 6: ...insert can lead to condensate leaks REMOVING THE DRAIN INSERT 1 Turn the ON OFF switch OFF 2 Remove the filter access door from the drain side of the dehumidifier 3 Remove the filter from the dehumid...

Page 7: ...OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF IM...

Page 8: ...Aprilaire com P O Box 1467 Madison WI 53701 1467 800 334 6011 F 608 257 4357 Printed in USA 2021 Aprilaire Division of Research Products Corporation 10015562 B2209245A 1 21...