Aprilaire E080 Quick Start Manual Download Page 4

SHEET 3 – REMOTE CONTROL USING MODEL 76 CONTROL

PARTS NEEDED 

(ADDITIONAL PARTS MAY BE REQUIRED)

•  Model E080/E100/E130
•  Model 76 Dehumidifier Control
•  Insulated duct
•  Thermostat wire
•  Duct fittings & hardware
•  20A outlet (E130 only)
•  Grilles (if required)
•  Drain pan and float switch (if required)

WIRING REMOTE CONTROL

A

B

C/-

R/+

DH

DH

M

ODEL 76

REMOTE CONTROL

ODT

SENSOR

DH    DH

REMOTE

+

-

A

B

HVAC EQUIP

Gh

Rf

Cf

Gs

W

Y

DAMPERS

VENT

DEH

FLOAT

SWITCH

NC

NO

DEHUMIDIFIER

CONTROL

BOARD

SET UP THE DEHUMIDIFIER FOR REMOTE CONTROL

After wiring the Model 76 to the dehumidifier as shown, use the power switch 
located on the outlet panel of the dehumidifier to power up the dehumidifier. The 
dehumidifier control should display 

OFF

.

1. 

Enter the Installer Set-Up menu by pressing and holding the MODE button on the 
dehumidifier control for 3 seconds; 

REMOTE DISABLED

 will appear on the display.

2. 

Press the 

 or 

 button to select 

REMOTE ENABLED

.

3. 

Press the MODE button again to complete set up (

DONE

 will appear on the 

display).

SEQUENCE OF OPERATION

The Model 76 Dehumidifier Control can be installed in any convenient location within 
the living space while the dehumidifier is installed in the space that is going to be 
dehumidified such as a crawl space, attic or basement. The relative humidity (RH) 
displayed on the Model 76 is the RH in the space where the dehumidifier is located 
– the dehumidifier communicates this to the Model 76. Changes to the dew point 
setting (1 = less dry, 7 = more dry) are made at the Model 76 and communicated 
to the dehumidifier. The dehumidifier can be turned on and off using the ON/OFF 
buttons of the Model 76.

Once every hour the dehumidifier will turn on its blower and sample the air in the 
zone to be dehumidified (sampling will also occur whenever the dew point setting 
is raised). If the dew point of the air is higher than the setting on the control, the 
dehumidifier compressor will turn on. When the dew point of the air is below the 
setting on the Model 76 Control, the dehumidifier will turn off.

When the Model 76 Control is wired to the dehumidifier in this application and after 
completing the set up (see 

SET UP THE DEHUMIDIFIER FOR REMOTE CONTROL

 

above), 

REMOTE

 will appear on the display of the dehumidifier control.

DEDICATED RETURN TO DEDICATED SUPPLY

FIGURE 1 

– DEHUMIDIFIER DUCTED DIRECTLY

4

Summary of Contents for E080

Page 1: ...76 in the living space 3 Two Zone Not recommended in HVAC zoning applications Whole house Basement Internal 4 External in Primary 5 Two Zone Not recommended in HVAC zoning applications Basement Whole...

Page 2: ...RATION The dehumidifier will automatically sample the air by turning on its blower and the HVAC blower if this option has been wired see WIRING INTERNAL CONTROL above and measuring the relative humidi...

Page 3: ...or Model 8910 Home Comfort Control must have a normally open NO all Aprilaire controls are normally open type or normally closed NC dry contact output and must be installed in the space that is going...

Page 4: ...can be installed in any convenient location within the living space while the dehumidifier is installed in the space that is going to be dehumidified such as a crawl space attic or basement The relati...

Page 5: ...ary Zone If there is no need for dehumidification in the Primary Zone the dehumidifier will then sample the air in the Secondary Zone When sampling in the Primary Zone the dehumidifier will energize t...

Page 6: ...ampers are not energized while the dehumidifier blower runs and the RH is measured If the RH is above the setting on the control the compressor will turn on and the Secondary Zone will be dehumidified...

Page 7: ...P Gh Rf Cf Gs W Y DAMPERS VENT DEH FLOAT SWITCH DEHUMIDIFIER CONTROL BOARD NC NO ODT SENSOR R C W Y EXISTING WIRE NEW WIRE USING THE DEHUMIDIFIER TO PRE CONDITION THE VENTILATION AIR The dehumidifier...

Page 8: ...AprilairePartners com P O Box 1467 Madison WI 53701 1467 800 334 6011 F 608 257 4357 Printed in USA 2020 Aprilaire Division of Research Products Corporation 10015107 B2209060A 11 20...