Set the O/B reversing valve jumper in the proper position
(Models 8346 and 8365 only)

The thermostat comes with an O/B terminal which can be configured to be
an ‘O’ terminal (for most heat pumps) or to be a ‘B’ terminal. Configure as an
‘O’ terminal if the heat pump reversing valve has heating as the default
position, configure as a ‘B’ terminal if the reversing valve has cooling as the
default position. 

CONSULT WITH THE HEAT PUMP MANUFACTURER TO DETERMINE WHICH
CONFIGURATION IS NEEDED.

5

To configure as an “O” Terminal, 

keep the pin jumper in this position.

To configure as an “B” Terminal, 

move the pin jumper to this position.

Remove the slide switch caps

for easier access.

O/B Reversing Valve Pin Jumper Position

Summary of Contents for 8344

Page 1: ...T PUMP NON PROGRAMMABLE MODEL 8348 HEAT COOL MULTI STAGE NON PROGRAMMABLE MODEL 8363 HEAT COOL 5 2 DAY PROGRAMMABLE MODEL 8365 HEAT PUMP 5 2 DAY PROGRAMMABLE MODEL 8366 HEAT COOL MULTI STAGE 5 2 DAY PROGRAMMABLE Installation Manual Electronic Thermostats ...

Page 2: ...pes should battery replacement be neglected 3 High Limit Temperature is the setting of an internal temperature controlled mechanical switch in the circuit between the RH and the W terminal W and W2 terminals for Model 8348 and 8366 This device will limit the room temperature should the contacts of the heat relay remain closed Applies to Models 8344 8348 8363 and 8366 only WARNINGS 120 volts may ca...

Page 3: ... from an outside wall DO NOT MOUNT THERMOSTAT Behind doors in corners or other dead air spaces In direct sunlight near lamps or other sources of heat On an outside wall or any wall exposed to an unconditioned space i e garage In the airflow path of a supply register or near outside doors On a wall where concealed pipes or ductwork will affect the thermostat temperature accuracy Step 2 Disassemble ...

Page 4: ...ostat place the thermostat to cover the old thermostat silhouette The base of the thermostat is raised to allow for wire routing behind the thermostat 2 Level the thermostat for appearance only and mark the mounting hole locations 3 Drill a 3 16 dia hole at the marked locations and install drywall anchors included Drywall anchors should be used unless installing on paneling or other hard surfaces ...

Page 5: ...stall the bottom screw not included to finish the installation Step 4 Set the ELEC GAS switch to the proper position Models 8344 8348 8363 and 8366 only Setting the switch to ELEC will cause the G terminal to energize with the W terminal on a call for heat Only the W terminal will energize on a heat call in the GAS position 4 Mounting the Thermostat to a Junction Box GAS ELEC Set ELEC GAS switch ...

Page 6: ...at pump reversing valve has heating as the default position configure as a B terminal if the reversing valve has cooling as the default position CONSULT WITH THE HEAT PUMP MANUFACTURER TO DETERMINE WHICH CONFIGURATION IS NEEDED 5 To configure as an O Terminal keep the pin jumper in this position To configure as an B Terminal move the pin jumper to this position Remove the slide switch caps for eas...

Page 7: ...tion from each wire Do not cut into the wire when stripping insulation as this can lead to eventual control failure 4 Secure the wires to the thermostat terminal strip according to the wiring diagram for the model being installed See Diagrams 1 2 3 Use a slotted screw driver with a 1 8 tip terminal screw driver Use color coding where possible i e red wire to R terminal white wire to W terminal etc...

Page 8: ...2 W2 1ST STAGE COOL 2ND STAGE COOL L1 L2 120 VAC 24 VAC 1ST STG COOL 2ND STG COOL COOLING EQUIPMENT Y1 C Y2 APRILAIRE MODEL 8348 OR 8366 THERMOSTAT LO HI W RC RH W2 Y Y2 G HI opens at 100 F 9 F LO closes at 41 F 9 F GAS ELEC AUTO ON Diagram 2 Model 8348 or 8366 Thermostat Wiring ...

Page 9: ... OUTDOOR HEAT PUMP UNIT FAN RELAY AUX HEAT R HEAT BLOWER EQUIPMENT C G W2 Y1 1ST STAGE COMPRESSOR L1 L2 120 VAC 24 VAC R G Y W2 O B C L COOL HEAT LO ON AUTO CHECK AUX APRILAIRE MODEL 8346 OR 8365 THERMOSTAT RED BLK WHT YLW ORG BLU BLU ORG YLW WHT GRN BLK RED ORG RED BLK GRN YLW WHT BLU RED BLU BLK WHT ORG YLW Diagram 3 Model 8346 or 8365 Thermostat Wiring NOTES 1 Wire colors shown for reference on...

Page 10: ...terminal may need to be configured see Step 4 4 MODELS 8348 8366 ONLY Raise the temperature an additional 2 3 and confirm that the second stage of heat W2 comes on after a 2 minute 1st stage minimum on time MODELS 8346 8365 ONLY Raise the temperature an additional 2 3 and confirm that the second stage of heat W2 comes on in four 4 minutes The green AUX LED located on top of the thermostat will lig...

Page 11: ...ur 4 minutes 9 Return the Mode switch to the Off position to stop the cool call MODELS 8346 8365 ONLY 10 Slide the Mode switch to the E Heat position 11 Use the ADJUST Up button to raise the temperature 2 3 above the current room temperature The W2 and G terminals will energize E HEAT on the display will begin to flash and the heating equipment should start 12 Return the Mode switch to the Off pos...

Page 12: ...is refers to how much the temperature will swing during control Use the ADJUST Up or ADJUST Down button to change this to 1 2 or 3 A higher differential will allow more temperature swing and fewer longer equipment cycles Press the LIGHT button when the desired differential has been set 5 Second Stage Differential Setting d2 MODELS 8348 8366 ONLY This setting controls how far from the first stage d...

Page 13: ...mind the homeowner to change the Water Panel in their humidifier Set the value to OFF to disable this feature Press the LIGHT button when the Water Panel indicator value has been set 8 Humidifier Type This feature will only be displayed if the Water Panel Change value is not set to OFF Use the ADJUST Up or ADJUST Down button to set this value to 1 if the home has an Aprilaire Model 400 whole house...

Page 14: ...mmendations on the filter in your particular application Set to 12 if the media is original Aprilaire High Efficiency Air Cleaner media Set the value to OFF to disable this feature Press the LIGHT button when the air filter indicator value has been set DONE will appear on the display and the thermostat will reset 13 LIGHT ADJUST CHANGE FILTER CHANGE FILTER LIGHT ADJUST WATER PANEL WATER PANEL TABL...

Page 15: ...le between the two selections and press the LIGHT button when done DONE will appear on the display and the thermostat will reset Step10 Set the current time and day of the week MODELS 8363 8365 8366 ONLY Press the CURRENT TIME button to access the clock Use the ADJUST Up and ADJUST Down buttons to set the correct hour value Make sure the correct AM PM designator shows Press the CURRENT TIME button...

Page 16: ...y As an ENERGYSTAR partner the thermostat Models 8363 8365 and 8366 only has been pre programmed with economical times and temperature settings Refer to the Operating Instructions if the program is to be changed CURRENT TIME Advance Time ADJUST MO AM Adjust Day of the Week CURRENT TIME Advance Time DONE 15 P O BOX 1467 MADISON WI 53701 1467 Products For Better Indoor Air Quality MADE IN USA Form N...

Reviews: