READ AND SAVE THESE INSTRUCTIONS

 CAUTION

1.  Read all instructions before beginning installation.
2.  Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
3.  Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4.  Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5.  Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6.  Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation 

to lower indoor humidity in the winter.

 WARNING

1.  120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. 

Leave power disconnected until installation/service is completed.

2.  Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.

SAFETy INSTRUCTIONS

Dehumidifer 

Control

ON/OFF 

button  

used to turn 

dehumidifier on 

and off

Up/Down 

buttons used to 

change humidity 

setting

MODE 

button 

used for optional 

ventilation feature

Inlet

Filter Access 

Door

Drain

Power 

Switch

Outlet

1

For product support, contact Aprilaire at 1-800-334-6011.
For sales inquiries, contact Sylvane at 800-934-9194, or visit Sylvane.com.

For product support, contact Aprilaire at 1-800-334-6011.
For sales inquiries, contact Sylvane at 800-934-9194, or visit Sylvane.com.

Summary of Contents for 1870F

Page 1: ...se ventilation to lower indoor humidity in the winter WARNING 1 120 Volts may cause serious injury from electric shock Disconnect electrical power before starting installation or servicing Leave power...

Page 2: ...n condensing Filter MERV 8 washable Airflow 310 CFM Table of Contents Safety Instructions 1 Specifications 2 Set Up Dehumidifier for Installation 3 Location Considerations 3 Drain Installation 4 Level...

Page 3: ...cient space for service on this side of the unit If locating the unit in an attic or crawl space a Model 76 Control mounted in the living space is recommended Refer to Model 76 Installation Instructio...

Page 4: ...oft tubing to curl up which may result in air lock Always install the dehumidifier in a condensate pan when locating in or above a finished space Adhere to local codes regarding draining of the conden...

Page 5: ...ny time if the humidity setting is lowered Your dehumidifier is equipped with two features that protect against unwanted energy consumption Defrost is a normal operating mode that helps to prevent sig...

Page 6: ...rm water and a mild detergent solution 5 Shake off the excess water from the filter 6 Replace the filter making sure the filter is secured in both the top and bottom filter rails 7 Replace the filter...

Page 7: ...crawl space sealed attic or other hard to access area a Model 76 can be installed in the living space and will operate as a remote control Refer to the Model 76 Installation Instructions and Owner s M...

Page 8: ...Terminal should be fully seated on the power board pins 2 Remove the side access panel and verify that the sensor is secured to the suction line 3 If the sensor is connected and secured to the refrig...

Page 9: ...ting Inlet air temperature is outside of the 50 F 104 F range or the dew point is below 40 F and there is a demand for dehumidification No action The compressor will not run if inlet conditions are ou...