TECHNICAL DATA
Temperature adjustment range:
30 – 50°C
Factory pre-set temperature:
41°C
Set temperature: must be commissioned on site to achieve desired temperature
Temperature control:
±2°C
Cold inlet temperature supply (min – max):
5°C – 30°C
Hot inlet temperature supply (min – max):
55°C – 100°C
Maximum working pressure (static):
1400 kPa
Working pressure range (dynamic):
20 – 500 kPa
Maximum unbalanced dynamic supply (hot/cold or cold/hot):
6 : 1
Minimum temperature differential between hot water inlet
and mixed water outlet to ensure shut off function:
10°C
Minimum temperature differential between mixed water outlet
and cold water inlet to ensure stable operation:
5°C
Minimum flow rate for stable operation:
AT80 Model
4 l/min
AT160 Model
8 l/min
AT240 Model
12 l/min
AT320 Model
16 l/min