1.  Restore power to the HVAC equipment.
2.  Set the thermostat mode to OFF and fan to AUTO.
3.  The display on the Air Cleaner Control should look like 

Figure 13

.

  • Verify that there is no activity in the “FILTERING” portion of the display.
4.  Press the “Event Clean” button on the Air Cleaner Control.
  • Verify that the blower starts.
  • Verify that the “FILTERING” portion of the display sequences (

Figure 14

).

  •  Verify that the LEDs on the LED base are sequencing on and off 

(

Figure 15

).

5.  Press the “Event Clean” button again to cancel the operation.
6.   Return the thermostat Mode and Fan to the desired setting.
Refer to the Owner’s Manual for details on the operation of the  
Air Cleaner Control.

INSTALL THE AIR CLEANER CONTROL

START UP

Filtering bars

will sequence on / off

LEDs will

sequence on / off

Filtering bars

will sequence on / off

LEDs will

sequence on / off

FIGURE 13

FIGURE 14

FIGURE 15

90-1322

90-1322

90-1322

SET UP

Jumper

FIGURE 12

90-1338

FILTER LIFE INDICATOR – SETTING THE REPLACEMENT FREqUENCy 

Set the jumper on the back of the Air Cleaner Control circuit board, as 
shown in 

Figure 12

, to the desired frequency for filter changes.

TABLE 3 – Filter Change Frequency

Jumper 

Position

Filter Change Setting

OFF

One calendar year (365 days)

A

6570 hours of use (9 months of continuous blower run time)

B

4380 hours of use (6 months of continuous blower run time)

C

2190 hours of use (3 months of continuous blower run time)

The factory default setting is OFF.

Summary of Contents for 4200

Page 1: ...000 1200 1400 1600 1800 2000 4200 09 12 16 20 25 30 35 4300 13 18 24 30 37 NA NA 4400 09 13 17 22 26 31 37 Electrical Voltage 18 30 VAC Max Current 2A maximum low voltage current for fan control MERV Minimum Efficiency Reporting Value 347 fpm 13 Airflow Capacity see Table 1 Replacement Media 4200 Model 213 with SelfSeal 4300 Model 313 with SelfSeal 4400 Model 413 with SelfSeal Max Equipment Weight...

Page 2: ...e LOCATING THE AIR CLEANER 29 Figure 1 Filtering Media Clearance 90 1317 Airflow Airflow Airflow 30 max 45 max Figure 4 Highboy Upflow Installation 90 1320 Airflow Figure 2 Horizontal Installation 90 1319 Leave 4 1 2 above LED Base to allow for installation of the Air Cleaner Control Airflow Airflow Figure 3 Highboy Installation 90 1318 Leave 4 1 2 above LED Base to allow for installation of the A...

Page 3: ...igure 5 90 1317 120 Volts may cause serious injury from electrical shock Disconnect power to the furnace air handler before starting installation Leave power disconnected until installation is completed WARNING 1 Disconnect power to the furnace or air handler at the electrical service panel The electronic controls that are included with the air cleaner are used to circulate air through the air cle...

Page 4: ...mostat to the Air Cleaner Control as shown in Diagram 2 or Diagram 3 Diagram 2 is for standard single thermostat systems Diagram 3 is for two transformer systems such as radiant heat with forced air cooling Replace the Air Cleaner Control on the backplate Option 1 Install the Air Cleaner Control Near the Thermostat R FURNACE OR AIR HANDLER C G Y W1 COOLING OR COMPRESSOR L1 L2 120 VAC 24 VAC HEAT O...

Page 5: ...OTE 2 NOT USED Diagram 2 Single Transformer Systems 90 1332 RC THERMOSTAT Y G RH W COOLING HEATING FAN GS W GF C R AIR CLEANER CONTROL NEW WIRE EXISTING WIRE LEGEND WIRE NUT B A R C TO RADIANT HYDRONIC HEAT SYSTEM TO FORCED AIR COOLING SYSTEM SEE NOTE NOT USED DISCONNECT EXISTING WIRE FROM THERMOSTAT G FAN TERMINAL AND USE WIRE NUT TO CONNECT TO GF WIRE FROM AIR CLEANER CONTROL NOTE IF THE TRANSFO...

Page 6: ...NLY RADIANT HEAT DO NOT WIRE THE EQUIPMENT TO THE W TERMINAL OF THE LED BASE AND JUMPER THE GF AND W TERMINALS ON THE LED BASE Option 2 Air cleaner Control Mounted on the Air Cleaner 1 Run a 5 conductor cable between the LED Base and the low voltage controls of the HVAC equipment 2 Remove the cover from the LED Base and wire to the low voltage controls of the HVAC equipment as shown in Diagram 4 3...

Page 7: ...ackplate from the Air Cleaner Control and install the backplate at the desired location for the Air Cleaner Control Do not install the Air Cleaner Control on supply ductwork 2 Run a 5 conductor cable between the Air Cleaner Control and the LED Base 3 Run a 5 conductor cable between the LED Base and the low voltage controls of the HVAC equipment 4 Remove the cover from the LED Base and wire the Air...

Page 8: ...in to cancel the operation 6 Return the thermostat Mode and Fan to the desired setting Refer to the Owner s Manual for details on the operation of the Air Cleaner Control INSTALL THE Air Cleaner CONTROL Start Up Filtering bars will sequence on off Filtering bars will sequence on off LEDs will sequence on off Figure 13 Figure 14 Figure 15 90 1322 90 1322 90 1322 SET Up Jumper Figure 12 90 1338 Filt...

Reviews: