background image

3651 WALNUT AVENUE, CHINO CA 91710 • PHONE (909) 664-9980 • 

APR-Rework.com 

 

Page 

56

  of 

79 

TB-10006 REV December 2018 

 

© 2018 DESCO INDUSTRIES INC 

 

 

Employee Owned

 

 

        

 

 

 

Focus Blower Setup

5400-0020 

 

Press Home Button 

 

Go to Motion Control Screen 

NZA-SRS-CAL 

 

Install NZA-SRS-CAL 

Install 5400-0020 into NZA-SRS-CAL 

 

Summary of Contents for APR-2000-SCS

Page 1: ...3651 WALNUT AVENUE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 1 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Scarab Site Cleaning System User Guide ...

Page 2: ...Using a Saved Cleaning Profile 28 Auto Profile 30 Collection Chamber Cleaning 31 Data Backup 33 Data Restore 34 Capture Screen Shot 35 Load Screen Shot 36 Ethernet Connection and File Management 37 Calibration and Adjustment 39 Setting the Home Position 41 Crosshair Laser Setup 43 Calibrating the Laser Height Sensor 45 External Thermocouple Calibration 52 Reflow Blower Calibration 53 Focus Blower ...

Page 3: ...rly trained Operate the unit from the type of power source indicated on the serial number label Use only the supplied power cord Avoid damage to the power cord If damage should occur replace it with the approved APR replacement power cord This CAUTION symbol on the equipment refers the user to the user guide for additional information This symbol appears next to the relevant information in the man...

Page 4: ... will be too dazzling to stare into for extended periods Momentary viewing is not considered hazardous since the upper radiant power limit on this type of device is less than the MPE Maximum Permissible Exposure for momentary exposure of 0 25 second or less Intentional extended viewing however is considered hazardous Crosshair Alignment Laser Module o A Class 3R laser is considered safe if handled...

Page 5: ...sulation category II Temperature Control Type Closed Loop Control Thermocouple Laser Class Crosshair Alignment Laser Module Maximum Output 5mW Pulse Duration N A Wavelength 650nm Divergence 2mrads Laser Height Sensor Module Maximum Output 1mW Pulse Duration 2 5mS Wavelength 660nm Divergence Parallel 0 5 mrads Divergence Perpendicular 2 mrads Maximum Source Temperature Reflow Head 350 C 662 F Pre H...

Page 6: ...ite Cleaning System addresses the industry needs with an automated system capable of cleaning components pads without contact The motorized design allows the system to clean without contact component pads up to 50mm x 50mm within a 101mm x 101 mm area The system can accurately and repeatedly clean pads with pitches of 0 2mm to 2 0mm The open ended board holder fits a wide variety of large small an...

Page 7: ...nnection 5 Crosshair Laser 16 Glue Scrapper Air Connection 6 Reflow Nozzle 17 USB Connection 7 Board holder Assembly 18 Shop Air Connection 8 Optional Under board Support 19 Monitor Connection 9 Circuit breaker 20 Power Connection 10 Nozzle and Fixture Storage 11 Vacuum Nozzle Scarab Site Cleaning System Components APR 2000 SCS 20 19 18 13 12 1 2 3 10 4 11 6 7 8 15 16 17 9 5 14 Laser Height Sensor...

Page 8: ...omplete Provide a location that allows the user to operate this machine in a comfortable well spaced environment Every Scarab Site Cleaning System has been factory assembled and calibrated Recalibration is not necessary after initial setup Verifying calibration and product functionality is strongly recommended prior to initial use Power up Sequence Attach an appropriate power plug to the stripped ...

Page 9: ...d always be 208VAC to 240VAC Measure from G to X This measurement will be 110VAC 125VAC Measure from G to Y This measurement will be 110VAC 125VAC Configuration 2 Measure from X to Y This measurement should always be 208VAC to 240VAC Measure from G to X This measurement will be 0 VAC Measure from G to Y This measurement will be 208VAC 240VAC Power Connector Connecting the Air Source 80 100 psi 5 5...

Page 10: ...9 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Insert the power cord plug into a recepticle Set the circuit breaker switch to the on position When the title screen appears your Scarab Site Cleaning System is ready for operation Connections Optional Air Source ...

Page 11: ...INDUSTRIES INC Employee Owned Click the log in icon The system has three levels of permissions operator engineer and administration modes Enter the appropripate password for the user level with the onscreen keyboard Default Operator password operator Default Engineer password engineer Default Administration password guru ...

Page 12: ...DUSTRIES INC Employee Owned Full Matrix Enable Glue Removal Option File Open Test Run File Save Perimeter Matrix Enable Alignment Laser Save Marker Location Test Stop Perimeter with Center matrix Start Location Go To Marker Location Board Clearance Component Pitch Application Setup Controls Application Setup Motion Control ...

Page 13: ...UT AVENUE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 13 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Motion Controls Z Axis X Y Axis Home Min Z Max Z Adjustment Adjustment ...

Page 14: ...ibration Calibration in Progress Repeat On Off Focus Heater Calibration Screen Capture Surround Heater Calibration Open Close Screen Shot Thermocouple Calibration Language Select Unmounts USB Drive Back up Restore Software Shutdown Restore Factory Settings User Guide Ethernet Icon Each dot corresponds to a different screen Select a screen by left clicking on the appropriate dot The first dot it th...

Page 15: ...e Hover the cursor over the user guide icon Left click the icon to activate Left click again to deactivate Software Shutdown APR recommends shutting down the software prior to removing power to the unit This will minimize the risk of file corruption to the computer s memory card Hover the cursor over the software shutdown icon Left click the icon to activate ...

Page 16: ...Tip language select Hover the cursor over the tool tip language select icon Right click on the mouse button to access the language options box The language option box displays showing the current language setting Use the scroll wheel to the language Right click the mouse button to save changes Left click the icon to activate Left click again to deactivate ...

Page 17: ...EV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Profile Window Displays the temperature profile and data table Edit Profile Changing profile information requires the profile to be unlocked Left click the Lock icon The profile is open for editting Profile Window Overview Operator Mode ...

Page 18: ...emperature Each line corresponds to a different heater Temperature can be changed in two ways Changing temperature Method 1 Left click the desired heater The cursor will change to double arrows Drag drop to the desired temperature Changing temperature Method 2 Right click the desired heater The temperature adjust dialog box will appear Use the up and down arrows to select the desired temperature C...

Page 19: ... click to remove a marker Changing Time Zones The default configuration is 4 heating zones and 1 for cooling An additional 4 zones of heating and 1 of cooling can be added The duration of each zone can be changed in two ways Adding additional time zones Hover the cursor over the time zone bar area located at the top of the graph The cursor will change to the zone icon Left click to add an addition...

Page 20: ...ethod 1 Left click the desired profile marker The cursor will change to double arrows Drag drop to the desired time Changing Profile Marker location Method 2 Right click the profile marker The time adjust dialog box will appear Use the up and down arrows to select the desired time Click ok to enter the desired time Repeatability verification If external thermocouple plots were saved as part of a p...

Page 21: ...s Hover the cursor over the temperature zone bar area located on the left of the graph The cursor will change to the marker icon Right click to remove a marker Changing Profile Marker location Method 1 Left click the desired profile marker The cursor will change to double arrows Drag drop to the desired time Changing Profile Marker location Method 2 Right click the profile marker The time adjust d...

Page 22: ... 22 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned New Cleaning Profile Press Home Button Go to Motion Control Screen Load PCBA into Board Holder Activate Laser Crosshair Center pad area over the preheater using crosshair laser Select Application ...

Page 23: ...Control Parameters Perimeter 1 2 Set Pitch Underfill Removal Upgrade Kit APR SCS UK1 adds the capability to assist in the removal reworkable underfill from PCBAs in designated areas Using the kit outside of the prescribed areas may result in damage When activated the areas designated for use with APR SCS UK1 will be visible in the Motion Control Screen and will display the Glue Icon Set Motion Con...

Page 24: ...TRIES INC Employee Owned Move crosshair laser to Start Location Save Start Location Go to Thermal Profile Screen If desired select Auto Profile 10 When Equipped with SCS UK1 Set Motion Control Parameters Perimeter with Center Matrix 1 2 Set Pitch When Equipped with SCS UK1 Set Motion Control Parameters Perimeter 1 2 Set Pitch ...

Page 25: ... TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Press Min Z Button 12 Start the Thermal Profile 13 The duration in this zone is defined by the motion control parameters Thermal adjustments only or Adjust the Thermal Profile on the Fly 11 Stop the Thermal Profile ...

Page 26: ...A 91710 PHONE 909 664 9980 APR Rework com Page 26 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Open Import Profile Cancel the Selection Press the Open Profile Icon Select the File Press the Open Icon ...

Page 27: ... December 2018 2018 DESCO INDUSTRIES INC Employee Owned Save Profile or Create Directory Press the Save Icon Name the File Select Location Save Create Directory Delete Cancel Transfer to External Memory Transfer to Internal Memory Internal Memory Location External Memory Location when available ...

Page 28: ... DESCO INDUSTRIES INC Employee Owned Using a Saved Cleaning Profile Activate Laser Crosshair Center pad area over the preheater using crosshair laser APR recommends using a fixture to maximize repeatability of the motion and thermal profiles Press Home Button Go to Motion Control Screen Load PCBA into Board Holder ...

Page 29: ...980 APR Rework com Page 29 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Press the Open Profile Icon Select the File Press the Go to Start L ti Press Min Z Button Go to Thermal Profile Screen 10 Start the Thermal Profile 11 ...

Page 30: ...assist in the creation of thermal profiles A thermocouple trigger is used to control the actions of the Scarab Start with the New Cleaning Profile instruction Go to Thermal Profile Screen Select Auto Profile 1st click lead free 2nd click lead profile 3rd click exit auto profile Attach thermocouple near start position on PCBA Connect thermocouple to TC1 Start the ThermalProfile ...

Page 31: ...3651 WALNUT AVENUE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 31 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Collection Chamber Cleaning ...

Page 32: ...3651 WALNUT AVENUE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 32 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned 5 10 parts or as needed Daily or as needed ...

Page 33: ...ONE 909 664 9980 APR Rework com Page 33 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Data Backup Left click the Data Backup Button Insert a USB flash drive with a 2GB or greater capacity into the USB connector ...

Page 34: ...NE 909 664 9980 APR Rework com Page 34 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Data Restore Right click the Data Backup Button Remove a USB flash drive with a 2GB or greater capacity from the USB connector ...

Page 35: ... REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Capture Screen Shot Press the Screenshot Icon Name the File Select Location Save Create Directory Delete Cancel Transfer to External Memory Transfer to Internal Memory Internal Memory Location External Memory Location when available ...

Page 36: ...80 APR Rework com Page 36 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Load Screen Shot Press the Save Icon Select File Create Directory Cancel Select Internal Memory Location Select External Memory Location when available ...

Page 37: ...rk com Page 37 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Ethernet Connection File Management Load or Open the APR Connect software Press the Ethernet Icon Enter the IP Address Connect the system to the network Record the IP Address ...

Page 38: ... files to the Scarab Site Cleaning System Press the Software Button to transfer new software to the Scarab Site Cleaning System Press the Manual Button to transfer a new manual to the Scarab Site Cleaning System Press the Download Profile Button to transfer files from the Scarab Site Cleaning System Press the Disconnect Button Press the Tool Tips Button to transfer updated tool tips to the Scarab ...

Page 39: ...51 WALNUT AVENUE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 39 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Calibration Adjustment Recommended Maintenance Schedule ...

Page 40: ...INC Employee Owned Required Calibration Adjustment Tools SCS LAT Laser Adjustment Tool ACK MFG Metric Feeler Gauges 9025 9000 5400 0020 5300 0017 5300 0019 SCS RFF Scarab Reflow Fixture SCS AFF Scarab Airflow Fixture SCS CALKIT NZA SRS CAL 7050 2262 5400 0040 5400 0039 4100 0175 4100 0174 4100 0172 4100 0173 SCS PMK Sold separately ...

Page 41: ...ES INC Employee Owned Setting the Home Position Move the vacuum nozzle to a spot roughly centered over the SCS LAT Manually drive head down until nozzle is approximately 2mm above SCS LAT Center the vacuum nozzle over cone at the center of the SCS LAT Top View Install the Laser Adjustment Tool SCS LAT Lock the SCS LAT into place ...

Page 42: ...Rework com Page 42 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Press Motion Control Icon Save Home Position Press Max Z Button Unlock Remove the SCS LAT 0 250 Adjust slide bar to 0 250mm drive head down center nozzle on the cone ...

Page 43: ...s Home Button Activate Laser Crosshair Adjust the crosshair laser SCS CALM Ensure the laser is flush with the bottom of the bracket Lock the SCS LAT Remove the laser assembly cover M2 Install the Laser Adjustment Tool SCS LAT Laser Radiation Warning Do not stare into the beam or view directly with optical instruments Laser components are sealed and replaced in their entirety ...

Page 44: ... 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Front of machine Loosen Adjust Tighten M3 Front of machine Front of machine Loosen Adjust Tighten M2 5 Loosen Adjust Tighten M2 5 Attach the laser assembly cover M3 Activate laser and verify location Repeat if necessary ...

Page 45: ...Sensor SCS HSLM Press Min Z Button Load PCBA into Board Holder Press Home Button Jog head to right limit Go to Motion Control Screen The reflow head is stopping below the normal height please check if PCBA is correctly loaded OK Laser Radiation Warning Do not stare into the beam or view directly with optical instruments Laser components are sealed and replaced in their entirety ...

Page 46: ...8 2018 DESCO INDUSTRIES INC Employee Owned Get Absolute Position Adjust Relative Position Read Analog Value Press Motion Control Icon 4 Use the keypad to enter 4 next to the Adjust Relative Position Icon Press Adjust Relative Position Icon 10 Go to Calibration Screen Slide PCBA right until it contacts nozzle ...

Page 47: ...2018 2018 DESCO INDUSTRIES INC Employee Owned 12 0 05 Use the keypad to enter 0 05 next to the Adjust Relative Position Icon Press Adjust Relative Position Icon 0 1mm 11 Press Save Work Surface Location Icon Has the vacuum nozzle been positioned 0 1mm above the reference YES 0 1mm Press and Hold Repeat10 ...

Page 48: ...ESCO INDUSTRIES INC Employee Owned Click yes to save the current position as the plane of operation YES Part 2 0 6 0 65mm 0 5 Use the keypad to enter 0 5 next to the Adjust Relative Position Icon 13 Press Adjust Relative Position Icon 14 M3 15 Remove the laser assembly cover 16 Verify laser position center of nozzle ...

Page 49: ... Verify laser position measure and record 17 3 8mm 5mm Save Settings Cancel X Y directional control Test Run Number Pad Press Glue Remover Icon Enter value from 17 19 18 Save Settings Close Panel 20 Laser Radiation Warning Do not stare into the beam or view directly with optical instruments Laser components are sealed and replaced in their entirety ...

Page 50: ...Absolute Position Icon Record the Value Press Read Analog Value Icon Record the Value Press Up button for 3 sec Press and hold the TUNE button for 3 sec until TUNE blinks then release t P1 t P1 appears Press Motion Control Icon 0 6 Use the keypad to enter 0 6 next to the Adjust Relative Position Icon Press Adjust Relative Position Icon 21 22 23 24 25 26 27 28 ...

Page 51: ...Get Absolute Position Icon 29 30 Compare Get Absolute Position from step 22 to Get Absolute Position from step 30 31 30 75 5000 5000 22 Press Read Analog Value Icon Record the Value 32 Compare Read Analog Value from step 23 to Read Analog Value from step 32 33 32 8 3000 3000 23 23 22 Step 30 Step 75 Step 32 Step 8 Calibration Complete 23 22 Step 30 Step 75 Step 32 Step 8 Repeat 13 0 6 0 65mm ...

Page 52: ...eft click the thermocouple calibration icon The current temperature will be displayed Plug the K type thermocouple tester into the matching external thermcouple connector Right click the thermocouple to calibrate selected thermocouple The current temperature will be displayed Left to cycle to next thermocouple Repeat until each thermocouple has been calibrated K type thermocouple tester Set knob t...

Page 53: ...Rework com Page 53 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Reflow Blower Calibration Setup Press Home Button Go to Motion Control Screen 9025 9000 5400 0020 SCS AFF Load SCS AFF onto 9025 9000 Attach SRN 11 to nozzle assembly ...

Page 54: ...B 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Press Min Z Button Verify arrow pointing down Verify alignment pins are in grooves of 5400 0020 Raise fixture into nozzle assembly Slide rails underneath fixture and lock Insert 5400 0020 in the SCS AFF Raise head 25mm ...

Page 55: ...TRIES INC Employee Owned The reflow blower has four settings low medium high and cool Press Reflow Blower Icon 1x Low 2x Medium 3x High 4x Cool 12 Power on the 5400 0020 10 Go to the Setup Calibration Screen 11 Save Settings 15 Access Airflow Adjustment 13 Low Medium High Cool 5 5m s 6 5m s 7 5m s max 14 Adjust Tolerance 0 5 ...

Page 56: ...64 9980 APR Rework com Page 56 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Focus Blower Setup 5400 0020 Press Home Button Go to Motion Control Screen NZA SRS CAL Install NZA SRS CAL Install 5400 0020 into NZA SRS CAL ...

Page 57: ...18 2018 DESCO INDUSTRIES INC Employee Owned The focus blower has two settings active and cool Power on the 5400 0020 Go to the Setup Calibration Screen Access Airflow Adjustment Press Reflow Blower Icon 1x Active 2x Cool Access Airflow Adjustment Save Settings 11 10 Adjust Active Cool 6m s max Tolerance 0 2 ...

Page 58: ...0 APR Rework com Page 58 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Surround Blower Setup 7050 2262 5400 0020 Press Home Button Go to Motion Control Screen Load 9025 9000 into Board Holder Install cover 9025 9000 9025 0560 ...

Page 59: ... Rework com Page 59 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Load 5400 0020 into 7050 2262 The focus blower has two settings active and cool Power on the 5400 0020 Go to the Setup Calibration Screen Access Airflow Adjustment ...

Page 60: ...09 664 9980 APR Rework com Page 60 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Adjust Active Cool 2m s 7m s Tolerance 0 1 Press Reflow Blower Icon 1x Active 2x Cool Access Airflow Adjustment 10 Save Settings 12 11 ...

Page 61: ...TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Reflow Heater Calibration Required Heater Calibration Kit SCS CALKIT 12M or As required SCS RFF Press Home Button Go to Motion Control Screen 9025 9000 Load 9025 9000 into Board Holder Connect probe to TC1 5300 0017 ...

Page 62: ...cember 2018 2018 DESCO INDUSTRIES INC Employee Owned Icon animates during calibration The system will auto save after completion Press Min Z Button Go to the Setup Calibration Screen Start Calibration 9025 9000 5300 0017 Insert TC probe 5300 0017 through Calibration Plate 9025 9000 and into SCS RFF ...

Page 63: ... Rework com Page 63 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Focus Heater Calibration 12M or As required Press Home Button Go to Motion Control Screen 9025 9000 Load 9025 9000 into Board Holder 5300 0017 Connect probe to TC1 ...

Page 64: ... Rework com Page 64 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Icon animates during calibration The system will auto save after completion Go to the Setup Calibration Screen Start Calibration Insert Thermal Probe into 9025 9000 ...

Page 65: ...Page 65 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Surround Heater Calibration Required Heater Calibration Kit SCS CALKIT 12M or As required Press Home Button Go to Motion Control Screen 9025 9000 Load 9025 9000 into Board Holder 5300 0017 ...

Page 66: ...e 66 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Icon animates during calibration The system will auto save after completion Go to the Setup Calibration Screen Start Calibration Insert Thermal Probe into 9025 9000 Move 9025 9000 into position ...

Page 67: ... 67 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Glue Remover Calibration Go to Motion Control Screen Press Min Z Button Adjust Z axis until 1 75mm above reference Load PCBA into Board Holder Install under board support APR MRS Demo PCB UBS SCS ...

Page 68: ...9980 APR Rework com Page 68 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned 1 75mm 0 90mm 0 85mm Deactivate Glue Remover Activate Glue Remover Calibration M1 5 Go to the Setup Calibration Screen Activate Glue Remover M1 5 10 ...

Page 69: ... Page 69 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Save Settings Cancel X Y directional control Test Run Number Pad Save Settings X 0 Y 0 Z 1 5 Enter values for X Y Z Width W 1 8 11 12 Go to Motion Control Screen 13 Press Home Button 14 ...

Page 70: ...2018 2018 DESCO INDUSTRIES INC Employee Owned Set Motion Control Parameters 1 2 Set Pitch Activate Laser Crosshair Center pad area over the preheater using crosshair laser Move crosshair laser to Start Location 15 16 17 18 Save Start Location 19 Press Min Z Button 20 Go to the Setup Calibration Screen 21 ...

Page 71: ...s it would during normal operation verify that the glue scraping button is selected as described in step 15 The glue remover calibration test will only work if the glue removal function has been activated Activate Glue Remover Calibration 22 23 X axis adjustment Y axis adjustment Reposition the glue scraper as shown in the following pictures Record the direction and number of button clicks 24 ...

Page 72: ...018 DESCO INDUSTRIES INC Employee Owned of button clicks 0 25mm X axis Value Direction Direction 1 1 25 Enter values from 25 25 26 26 27 Save Settings 28 Deactivate Glue Remover 29 Go to Motion Control S 30 Go to Start L ti 31 Press Min Z Button 32 of button clicks 0 25mm Y axis Value Direction Direction 1 1 26 ...

Page 73: ...A 91710 PHONE 909 664 9980 APR Rework com Page 73 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Go to the Setup Calibration Screen Activate Glue Remover Calibration 34 35 33 24 12 months or as needed ...

Page 74: ... CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 74 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Solder Path Cleaning Loosen screws Rotate Assembly Cover the preheater Remove M3 screws ...

Page 75: ...work com Page 75 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Press the Open Profile Icon Select the CleanSCS rem Press the Open Icon Run the Profile Clean the vacuum tube Tube will be hot Stop the Profile Allow System to Cool 10 11 ...

Page 76: ...UE CHINO CA 91710 PHONE 909 664 9980 APR Rework com Page 76 of 79 TB 10006 REV December 2018 2018 DESCO INDUSTRIES INC Employee Owned Align tube to rubber cup and tighten screws Replace screws Rotate Assembly 12 13 14 ...

Page 77: ...ed Alternate Software Installation Transfer the file to a USB flash drive with a 2GB or greater capacity into the USB connector Download the latest version of the Scarab software from http apr rework descoindustries com Software Downloads aspx Turn off power to the unit Insert a USB flash drive with a 2GB or greater capacity into the USB connector ...

Page 78: ...mber 2018 2018 DESCO INDUSTRIES INC Employee Owned Factory Restore Hover the cursor over the factory restore icon Left click the factory restore icon to restore saved settings Save Factory Default Hover the cursor over the factory restore icon Right click the factory restore icon to save the settings ...

Page 79: ...ance Kit MFR FTKIT Fitting Air Hose Kit shop air connections CALIBRATION KIT SPARE PARTS SCS UBS Under Board Support Scarab Site Cleaning System SCS CALKIT Calibration Kit SCS CCK Collection Chamber Kit SCS VR Venturi Replacement SCS VS1 Vacuum Solenoid 3 port SCS VS2 Vacuum Solenoid 4 port SRS SPK Surround Preheater Kit 2 heaters SRS PB Preheater Blower SRS PHO Preheater O ring SCS IOPCB Scarab I...

Reviews: