![Appsys ProAudio Flexiverter AES3 User Manual Download Page 10](http://html.mh-extra.com/html/appsys-proaudio/flexiverter-aes3/flexiverter-aes3_user-manual_2955503010.webp)
User's Manual
5.
CLOCK SETTINGS
5.1.
Clock sources and indication
The flexiverter can be clocked from every interface (acting as clock slave), or can
run on its internal clock (acting as clock master).
Clock source
"Clock" Indication (Example)
Remarks
AES3(A) Ch1/2
⬤
◌
◌
◌
AES3 Port A
AES3 Port B
AUX
FlexLink
◌
⬤
◌
◌
44.1 kHz
48 kHz
x2
x4
Channel 1/2 on port A is taken as
clock source and must be present
AES3(B) Ch1/2
◌
⬤
◌
◌
AES3 Port A
AES3 Port B
AUX
FlexLink
◌
⬤
◌
◌
44.1 kHz
48 kHz
x2
x4
Channel 1/2 on port B is taken as
clock source and must be present
Internal ("INT")
⬤
⬤
◌
◌
AES3 Port A \
INT
AES3 Port B /
AUX
FlexLink
◌
⬤
◌
◌
44.1 kHz
48 kHz
x2
x4
Flexiverter acts as clock master.
AUX
◌
◌
⬤
◌
AES3 Port A
AES3 Port B
AUX
FlexLink
◌
⬤
◌
◌
44.1 kHz
48 kHz
x2
x4
Only available with AUX installed.
AUX card acts as clock master.
Use an AUX-WORDCLOCK if you
need BNC wordclock I/O.
FlexLink
◌
◌
◌
⬤
AES3 Port A
AES3 Port B
AUX
FlexLink
◌
⬤
◌
◌
44.1 kHz
48 kHz
x2
x4
Clock is taken from the peer
device (Flexiverter or Multiverter)
LED color
Meaning
◌
off
Interface not active / not involved
⬤
green
Selected, locked and synced
⬤
red
No valid clock. No input connected or no master clock signal detected
❇
yellow blinking
Clock setting active. Press CLOCK button to go to the next clock source.
After 4 seconds, selection mode is terminated and the selected mode
comes into effect.
5.2.
Selecting the Clock Source
Long-press the
Clock
button until the LEDs are blinking yellow.
Current clock source/modes is shown by blinking LED(s).
10