AR2010 USB Stick Synthesizer
User Manual
12. SYSTem:BOOTSTATE [0-5]
This command specifies a previously saved state to be loaded upon device startup. In addition to factory
default state 0, there are 5 re-writeable memory locations. Any of these 6 boot states can be selected by
choosing an index between 0 and 5. The restored parameters are the
PLL mode, frequency, reference
divider, reference internal/external, reference frequency, max/min power setting, output power, RF power
(on AR2010-4400 models only).
Syntax
SYST
:BOOTSTATE
Space
0-5
There are 6 memory locations, numbered 0 through 5. Memory location 0 contains the factory default
settings, while locations 1-5 are user re-writeable using SYSTem:BOOTSTATE.
Example
SYST:BOOTSTATE 1
This command specifies state 1 to be loaded upon device powerup.
Default Condition
The factory default setting for
SYST:BOOTSTATE
is 0.
Applied Radar, Inc.
Revision 2.0.1
43