2 3 |
P a g e
HO High Output System Specifications
EQUIPMENT SPECIFICATIONS
Residential Crossover systems (high output lamps)
MODEL
UV-SPH-5-HP
UV-SPH-5P-HP
UV-SPH-5U-HP
UV-SPH-10-HP
UV-SPH-10P-HP
UV-SPH-10U-HP
UV-SPH-15-HP
UV-SPH-15P-HP
UV-SPH-15U-HP
UV-SPH-25-HP
UV-SPH-25P-HP
UV-SPH-25U-HP
UV-SPH-40-HP
UV-SPH-40P-HP
UV-SPH-40U-HP
Flow Rate
30mJ/cm
2
@ 95% UVT
5.0 gpm
10 gpm
15 gpm
25 gpm
40 gpm
18.91 lpm
37.9 lpm
57 lpm
95 lpm
151 lpm
1.1 m
3
/hr
2.3 m
3
/hr
3.4 m
3
/hr
5.7m
3
/hr
9.3m
3
/hr
Flow Rate
40mJ/cm
2
@ 95% UVT
3.0 gpm
7.0 gpm
11 gpm
19 gpm
31 gpm
11 lpm
26 lpm
42 lpm
72 lpm
120 lpm
0.68 m
3
/hr
1.6 m
3
/hr
2.5 m
3
/hr
4.3 m
3
/hr
7.0 m
3
/hr
Flow Rate
Hot Water (-HW suffix) model
30mJ/cm
2
@ 75% UVT
2.8 gpm
7.0 gpm
9.8 gpm
16 gpm
28 gpm
11 lpm
26 lpm
37 lpm
61 lpm
110 lpm
0.6 m
3
/hr
1.6 m
3
/hr
2.2 m
3
/hr
3.6 m
3
/hr
6.4 m
3
/hr
Flow Rate
Low UVT (-50 suffix) model
30mJ/cm
2
@ 50% UVT
1.7 gpm
4.2 gpm
6.1 gpm
10 gpm
17 gpm
6.4 lpm
16 lpm
23 lpm
38 lpm
64 lpm
0.4 m
3
/hr
1.0 m
3
/hr
1.4 m
3
/hr
2.3 m
3
/hr
3.9 m
3
/hr
Flow Rate
TOC (-TOC suffix) model
150mJ/cm
2
@ 98% UVT
0.8 gpm
2.0 gpm
2.8 gpm
5.1 gpm
8.0 gpm
3.0 lpm
7.6 lpm
11 lpm
19 lpm
30 lpm
0.2 m
3
/hr
0.5 m
3
/hr
0.6 m
3
/hr
1.1 m
3
/hr
1.8 m
3
/hr
Port Size
¾”MNPT
¾”MNPT
1”MNPT
1”MNPT
1 ½”MNPT
Electrical
90-265V/50-60Hz. 1.5A Max.
Plug Type
American: NEMA 5-15P
Lamp Power (Watts)
18
34
45
67
101
Power (Watts)
20
36
48
72
108
Replacement Lamp
UV-SPH-5-HPL
UV-SPH-10-HPL
UV-SPH-15-HPL
UV-SPH-25-HPL
UV-SPH-40-HPL
Replacement Sleeve
UV-SPH-2SLV
UV-SPH-10-HPSLV UV-SPH-15-HPSLV UV-SPH-25-HPSLV UV-SPH-40-HPSLV
Reactor
Dimensions
8.9 x 29.8 cm
(3.5 x 11.7”)
8.9 x 41.8 cm
(3.5 x 16.5”)
8.9 x 50.8 cm
(3.5 x 20.0”)
8.9 x 68.3 cm
(3.5 x 26.9”)
8.9 x 103.4 cm
(3.5 x 40.7”)
Chamber Material
316L Stainless Steel, A249 Pressure Rated Tubing
Controller Dimensions
21.7 x 10.8 x 10.2 cm (8.6 x 4.2 x 4”)
Operating Pressure
0.7-10.3 bar (10-150 psi)
Operating Water Temperature
2-40° C (36-104° F)
UV Monitor
YES on all UV-SPH-U-HP models. Upgrade available for UV-SPH-P-HP models
(NOT available on UV-SPH-HP models)
Solenoid Output
YES (optional solenoid module (UV-MOD-SOL1) sold separately)
Dry Contacts
YES (remote alarm module (UV-MOD-RAM) sold separately)
4-20mA Output
YES (4-20mA module (UV-MOD-420) sold separately)
Temperature Mgmt. Valve
UV-MOD-TRV0.75
UV-MOD-TRV1
UV-MOD-TRV1.5
Cooling Fan
OPTIONAL (UV-MOD-FAN sold separately)
Lamp Change Reminder
YES
Lamp Out Indicator
YES
Shipping Weight
4.5 kg
(9.9 lbs)
5.4 kg
(11.9 lbs)
6.0 kg
(13.2 lbs)
7.3 kg
(16.1 lbs)
9.8 kg
(21.6 lbs)