Applied Membranes AAA-1005 Manual For Installation, Operation And Maintenance Download Page 11

Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System 

Copyright © 2014 Applied Membranes, Inc.  

All Rights Reserved.

 

Page 11 

 

1.  Determine the desired location for your RO Faucet 

The product water faucet may be installed on any flat surface at least 2” in diameter.  Check the underside 
of the location for interference.  The standard faucet that is supplied with the system requires a ½” diameter 
hole.  The optional air-gap faucet requires a larger hole of ¾” to allow for the additional tubing connections 
required. 

 

 

Stainless Steel Sinks 

Begin by placing a piece of masking tape or duct tape on the determined location where the hole is to be 
drilled.  Make a small indent to mark the desired drilling location using a center punch.  Drill a pilot hole with 

” metal drill bit.  Enlarge the hole using a ¼” metal drill bit, using factory approved method or approved 

plumbing practice. 

 

 

Porcelain/Enamel Sinks or Tile Countertop 

Sinks of this type are very easy to damage due to the nature of the materials of construction.  A successful 
installation into these sinks requires a knowledgeable technician with the proper cutting tools.  We strongly 
recommend the use of a “Relton” type device.  Follow the directions that accompany the tool carefully. 

 

2. Faucet Installation 

Above the Countertop 

1.  Small Rubber Washer 
2.  Metal Faucet Hole Cover 
3.  Large Rubber Washer 

 
Below the Countertop 

4.  Plastic Locating Washer 
5. Metal Lock Washer 
6. Brass Nut 

 
Installed in/on tubing: 

7.  Plastic Tubing Insert 
8.  Plastic Ferrule  

(recommended)

 

9. Brass Ferrule 

(included only 

for those who prefer to use 
brass instead of plastic)

 

10. Brass Compression Nut 

 

  Slide the small rubber washer, then the metal cover, then the large rubber faucet over the mounting 

tube onto the faucet base, in that order so that the small rubber washer is on top. 

  Insert the mounting tube into the hole in the sink and position the faucet correctly. 

  From under the sink, install the plastic locating washer followed by the metal lock washer onto the 

threaded mounting tube, and secure them with the brass nut.  Screw on the brass nut and tighten. 

  Feed the brass compression nut onto the yellow tubing, threaded side facing the end, then feed the 

plastic ferrule and install the tubing insert into the end of the tubing.  Insert the end of the tubing into the 
faucet mounting tube as far as it will go then tighten the nut with a wrench. 

 

Note: 

 Only one ferrule is required.  We recommend using the plastic ferrule.  The brass ferrule is included only for those 

who prefer to use brass instead of the plastic.  The unused ferrule may be discarded. 
 

Note:  

Non-Air Gap Faucet – Comes with the system.  (Air Gap may be purchased separately - part number  

H-T5022.)  Some states require the use of an air gap faucet.  Check your local plumbing code to assure compliance.  

Summary of Contents for AAA-1005

Page 1: ...www appliedmembranes com sales appliedmembranes com Document ID AAA5 MANUAL Revision 06 04 14 Manual for Installation Operation and Maintenance of System Flow Rate Model Number 12 Gallons Per Day AAA 125 24 Gallons Per Day AAA 245 36 Gallons Per Day AAA 365 System Flow Rate Model Number 50 Gallons Per Day AAA 505 75 Gallons Per Day AAA 755 100 Gallons Per Day AAA 1005 ...

Page 2: ...d every three to six months depending on the quality of the feed water supply Conditions for Operation Source Water Supply Community Private Non Chlorinated or chlorinated as long as the carbon filter is in place and replaced every 6 months Membranes will be damaged by chlorine System Pressure 40 psi minimum 100 psi maximum Temperature 4º 38º C 40º 100º F Maximum Supply TDS Level 1500 ppm mg L Tur...

Page 3: ...nths 2nd Stage Carbon block pre filter Every 3 6 months 3rd Stage Carbon block pre filter Every 3 6 months 4th Stage Reverse osmosis membrane Every 12 months 5th Stage Post carbon filter Every 3 6 months Connection Location Tubing Color System Feed IN From feed line to port at the entrance of the first filter housing Blue Reject Water From the flow restrictor to the drain saddle Black Product Wate...

Page 4: ...uded with the system Variable speed drill with 7 16 drill bits and 7 16 open end wrenches or adjustable Phillips screwdriver Utility knife Teflon tape Check Location Determine the location for the installation of the RO system Avoid locations where the system might come in contact with hot water pipes or other hazards Determine the location for the faucet Check to see that drilling the faucet hole...

Page 5: ...nd Tubing Compression fittings are used throughout the system To ensure an optimal seal tubing should be cut with the end square An angled cut or distortion of the tubing will not provide an efficient seal and may cause leaks Determine the length of tubing needed for each connection and cut each segment of tubing to the appropriate length To ensure a secure seal using quick connect fittings Push t...

Page 6: ...Installation and Service Manual Under the Counter Point of Use 5 Stage Reverse Osmosis System Copyright 2014 Applied Membranes Inc All Rights Reserved Page 6 ...

Page 7: ...he sink or if water continues to come out of the faucet turn off the main supply at the entry to the house Feed Adapter Installation For this step you will need o Wrench o Teflon Tape Feed Adapter Kit Blue Tubing Slip Joint Adapter with washer Ball Valve with nut 1 Install the ball valve into the slip joint adapter Wrap the threads on the ball valve with Teflon tape approximately 3 wraps Screw the...

Page 8: ...4 Connect the other end of the blue tubing to the feed port on the RO System Feed Valve OPEN Position Feed Valve CLOSED Position Drain Saddle Installation For this step you will need o Variable speed drill w and drill bits o Phillips Screwdriver Drain Saddle Assembly Black Tubing 1 Drill a hole in the drain pipe a Select a location for the drain hole based on the design of the plumbing It should b...

Page 9: ... with the hole in the drain saddle A drill bit or other long narrow object may be used to help align correctly d Use Phillips screwdriver to tighten the clamp Avoid over tightening 3 Install the drain tubing a Slide the black nut onto the end of the black plastic tubing threads facing outward b Insert the end of the black tubing into the fitting on the drain saddle c Secure the connection by tight...

Page 10: ...age tank It has been factory charged and covered with a black cap 1 Locate the in out port on the top of the tank Connect the tank ball valve by threading onto the fitting Do not over tighten 2 Insert the tubing into the quick connect fitting on the ball valve 3 Connect the other end of the orange tubing to the tee on the inlet of the post carbon filter Tank Valve in OPEN Position Tank Valve in CL...

Page 11: ...tertop 1 Small Rubber Washer 2 Metal Faucet Hole Cover 3 Large Rubber Washer Below the Countertop 4 Plastic Locating Washer 5 Metal Lock Washer 6 Brass Nut Installed in on tubing 7 Plastic Tubing Insert 8 Plastic Ferrule recommended 9 Brass Ferrule included only for those who prefer to use brass instead of plastic 10 Brass Compression Nut Slide the small rubber washer then the metal cover then the...

Page 12: ...erclockwise until fully open the handle should be in line with the tubing as it enters the connection Check the stem seal for leakage If necessary tighten stem nut lightly Turn storage tank valve one quarter turn counterclockwise to open the valve the handle should be in line with the tubing as it enters the connection Open the product water faucet and let the water flow until all the air has been...

Page 13: ...filter housings Use a filter wrench if the housings are too tight 2 Discard used filters but save o rings for re use 3 Clean inside of all housings with a mild soap solution and then rinse with RO water 4 Lubricate the o ring and replace in filter housing 5 Insert the new filters into the appropriate housings and replace the housings onto the system 6 Disconnect the post filter by removing the fit...

Page 14: ... pump may be required Change in feedwater temperature The reverse osmosis membrane used in your unit is rated at 77ºF and 60psi Water production will decrease approximately 1 5 for each degree that your incoming water is below 77ºF It may be necessary to change to a higher flow membrane and flow restrictor Storage tank pressure is too low Check pressure with gauge and refill to maximum 8 psi Filte...

Page 15: ... M T1812A100 H R1000QC Other Replacement Components Part Description Image H H14FWW33 Filter Housing White OR H10F O Ring for Filter Housing PV2012PME Membrane Housing H S4010ANW Storage Tank White 4 4 Gallon 3 2 Gal Usable Bladder Tank H J2021KW Clip Membrane Housing to Inline Filter H J2025PW Membrane Housing Clip Part Description Image H T5019 Faucet Non Airgap Long Reach Chrome H V1050W QC Shu...

Page 16: ...not be liable for damages or delay caused by defective material Products returned to SELLER for warranty examination must be shipped freight prepaid SELLER S Liability SELLER SHALL NOT BE LIABLE FOR PROSPECTIVE PROFITS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES NOR SHALL RECOVERY OF ANY KIND AGAINST SELLER BE GREATER IN AMOUNT THAT THE PURCHASE PRICE OF THE SPECIFIC GOODS SOLD AND CAUSING THE AL...