2. Install the drain clamp
a. Remove the adhesive backing from the saddle pad and adhere
to the pipe, positioning the hole in the pad to the drilled pipe
hole.
b. Place one half of the plastic drain saddle assembly on each side
of the drain pipe with the fitting, and clamp loosely using the nuts
and bolts included.
c. Align the hole drilled in the drain pipe with the hole in the drain
saddle. A drill bit or other long narrow object may be used to
help align correctly.
d. Use Phillips screwdriver to tighten the clamp. Avoid over-
tightening.
3. Install the drain tubing.
a. Slide the black nut onto the end of the black plastic tubing,
threads facing outward.
b. Insert the end of the black tubing into the fitting on the drain
saddle.
c. Secure the connection by tightening the nut onto the
threaded fitting.
4. Connect to the RO System
Connect the other end of the tubing to the ‘out’ side of the flow
restrictor on the RO System.
NOTE: Some states require the use of an air gap faucet. Check your local plumbing code to assure