~ 16 ~
Heater chamber without the top cover
11.3.3
If you can’t find the trouble shooting refer to the above mentioned, please replace a new
electronic module.
12.
Poor dry result
If the laundry is hot and damp at the end of the dry cycle, please check for:
12.1
Wrong dry mode
: Make sure the dry mode is condensing or venting dry.
12.2
The cold faucet is off
: Turn on the cold faucet in condensing dry operation.
12.3
No condensing water intake
: Check for the inlet valve for cold water in condensing dry
operation.
12.4
Venting fan is covered
: Remove the metal cover on the venting fan, and connect the
exhaust duct in venting dry operation.
13.
Venting fan won’t rotate
I
n the venting dry cycle, if the venting fan will not rotate, please check for it as following:
13.1
Fan’s impeller blocked:
Turn the impeller of the venting fan by hand, when the unit is
power off, to check the impeller is blocked by some foreign objects. Clean it, and test it
again.
13.2
Poor wire connection to fan:
Check for the wiring between the following two mating
terminals.