Appareo Stratus Power Installation Instructions Manual Download Page 12

600840-000041 Stratus Power Installation Instructions

Rev. 1.0

Last Revised: December 15, 2016

Page 12 of 12

Sine-on-Random for 
Category U

8.8.2

Equipment tested to Category U.
Curve G.

Explosive Atmosphere

9.0

Equipment identified as Category X, no test 
performed.

Waterproofness

10.0

Equipment identified as Category X, no test 
performed.

Fluids Susceptibility

11.0

Equipment identified as Category X, no test 
performed.

Sand and Dust

12.0

Equipment identified as Category X, no test 
performed.

Fungus Resistance

13.0

Equipment identified as Category X, no test 
performed.

Salt Fog

14.0

Equipment identified as Category X, no test 
performed.

Magnetic Effect

15.0

Equipment tested to Category Y.

Power Input

16.0

Normal Operating 
Conditions (dc)

16.6.1

Equipment tested to Category BXX.

Voltage (average value dc)

16.6.1.1

Equipment tested to Category BXX.

Abnormal Operating 
Conditions (dc)

16.6.2

Equipment tested to Category BXX.

Voltage Spike

17.0

Equipment tested to Category B.

Audio Frequency Conducted 
Susceptibility

18.0

Equipment tested to Category B.

Induced Signal Susceptibility

19.0

Equipment identified as Category X, no test 
performed.

Radio Frequency Susceptibility

20.0

Equipment identified as Category X, no test 
performed.

Emission of Radio Frequency 
Energy

21.0

Equipment tested to Category B.

Lightning Induced Transient 
Susceptibility

22.0

Equipment identified as Category X, no test 
performed.

Lightning Direct Effects

23.0

Equipment identified as Category X, no test 
performed.

Icing

24.0

Equipment identified as Category X, no test 
performed.

Electrostatic Discharge

25.0

Equipment tested to Category A.

Fire, Flammability

26.0

Equipment identified as Category X, no test 
performed.

Table 7: DO-160G tests performed

Summary of Contents for Stratus Power

Page 1: ...ot be disseminated or redistributed without the written permission of Appareo Systems LLC APPAREO SYSTEMS LLC FARGO NORTH DAKOTA 58102 Stratus Power Installation Instructions Document Number 600840 000041 Document Type Certification Last Revised 15 December 2016 Rev 1 0 Sheet 1 of 12 Stratus Power Installation Instructions ...

Page 2: ...in this guide Unauthorized replication of this guide is prohibited Appareo Appareo Systems Stratus Power and the Appareo and Stratus Power logos are either registered trademarks or trademarks of Appareo Systems LLC All other trademarks and registered trademarks are the sole property of their respective owners Appareo Systems LLC 1830 NDSU Research Circle North Fargo ND 58102 USA Visit us on the we...

Page 3: ...uirements 6 1 9 Limitations for installation 6 1 10 Circuit protective device marking 6 2 Mounting Stratus Power 7 3 Wiring Stratus Power 8 4 Troubleshooting 10 Technical Assistance 10 Appendix A 11 List of Figures Figure 1 Mounting location 7 Figure 2 Installing Stratus Power 8 Figure 3 Harness 9 Figure 4 Back of Stratus Power 9 List of Tables Table 1 TSO compliance 5 Table 2 TSO deviations 5 Tab...

Page 4: ...cumentation Document Number Title Appareo 600845 000028 Stratus Power Maintenance Manual FAA AC 43 13 1B Acceptable Methods Techniques and Practices Aircraft Inspection and Repair FAA AC 43 13 2B Acceptable Methods Techniques and Practices Aircraft Alterations FAA TSO C71 Airborne Static DC to DC Electrical Power Converter For Air Carrier Aircraft RTCA DO 160G Environmental Conditions and Test Pro...

Page 5: ...alification testing was performed to DO 160G not DO 60 Table 2 TSO deviations 1 4 Environmental qualifications Stratus Power is tested to DO 160G The Stratus Power Environmental Qualification form is found in Appendix A of this document 1 5 Equipment specifications Characteristic Specification Width 1 848 inches 46 95 mm Height 1 848 inches 46 95 mm Depth 1 391 inches 35 32 mm Stratus Power Unit W...

Page 6: ...153510 000040 1 Stratus Power Panel Cover 353070 000074 1 Screw 356060 000100 2 Power Connector Receptacle 251015 000115 1 Connector Terminals 251015 000116 2 Table 5 Supplied hardware 1 8 Unpacking inspection requirements When unpacking Stratus Power visually inspect for any damage to the unit or missing components If damage or missing parts are present contact Appareo 1 9 Limitations for install...

Page 7: ...earance in the front and back of the unit based on the dimensions given in Table 3 ATTENTION Process may result in metal shavings Ensure that they do not fall behind the aircraft panel 3 Drill out a circle in the mounting location with a 1 inch drill bit using the measurements in Figure 1 Then cut the notch in the top of the hole Figure 1 Mounting location 4 Place the Stratus Power unit behind the...

Page 8: ...gauge wiring and install it in accordance with FAA AC 43 13 1B and AC 43 13 2B Wire length and routing will vary by installation The installer must also supply a circuit protective device for use with Stratus Power Use a 2A breaker for 28V aircraft and a 4A breaker for 14V aircraft 1 Wire Stratus Power according to the diagrams below Provide a service loop Pin Pin Name Description 1 Power 10 32 VD...

Page 9: ...er and ensure that the breaker is pushed in b On the power harness place the negative probe of a multimeter on Pin 2 and the positive probe on Pin 1 c Measure the voltage across the two wires using a multimeter The voltage reading should be equal to your aircraft power d Disconnect aircraft power 3 Connect the power receptacle into the header on the back of Stratus Power Figure 4 Back of Stratus P...

Page 10: ... Power before connecting any devices 4 Troubleshooting Problem Troubleshooting Steps Stratus Power is not powering a device x Verify that the circuit protective device is functioning correctly x Verify that the polarity on the power connector is correct Technical Assistance For support please contact Appareo at support appareo com By mail 1830 NDSU Research Circle North Fargo ND 58102 United State...

Page 11: ... 3 Equipment tested to Category F1 Operating High Temperature 4 5 4 Equipment tested to Category F1 In Flight Loss of Cooling 4 5 5 Equipment identified as Category X no test performed Altitude 4 6 1 Equipment tested to Category F1 Decompression 4 6 2 Equipment identified as Category X no test performed Overpressure 4 6 3 Equipment identified as Category X no test performed Temperature Variation 5...

Page 12: ...ed to Category BXX Voltage average value dc 16 6 1 1 Equipment tested to Category BXX Abnormal Operating Conditions dc 16 6 2 Equipment tested to Category BXX Voltage Spike 17 0 Equipment tested to Category B Audio Frequency Conducted Susceptibility 18 0 Equipment tested to Category B Induced Signal Susceptibility 19 0 Equipment identified as Category X no test performed Radio Frequency Susceptibi...

Reviews: