![Appareo Stratus ES Installation Instructions Manual Download Page 42](http://html.mh-extra.com/html/appareo/stratus-es/stratus-es_installation-instructions-manual_2954815042.webp)
600840-000031 Stratus ES/ESG Installation Instructions
Rev. 2.2
Last Revised: February 20, 2018
Page 42 of 45
The screen displays a Built in Test
(BIT) failure
The display screen will display a
warning message and a degraded
state indicator
if any of
Stratus ES/ESG’s BITs fail.
The Stratus ES/ESG screen might display a warning
message with the instructions below. Below is guidance
regarding how to assess the failure:
•
PRESS FUNC TO CLEAR
: A non-critical error has
been detected. The transponder will run in a
degraded state until the error is resolved. Contact
Appareo for further assistance.
•
PLEASE RESTART UNIT
: A critical error has been
detected. Restarting the unit may fix the error. If the
message returns after restarting, contact Appareo
for further assistance.
•
PLEASE SHUTDOWN UNIT
: A critical error has
been detected. Power off the unit and do not turn it
back on. Contact Appareo for further assistance.
•
OVERHEATED
:
The transponder has overheated.
Transponder function will resume when the
transponder cools down.
•
WAITING TO BE UNSTUCK
: A key has been
depressed for more than 20 seconds. If a key is
stuck, try to unstick the key.
•
WAITING FOR RELEASE
: The external
suppression input is constantly in a suppressed
state. Contact Appareo for further assistance.
•
ATTEMPTING TO RECOVER
: A squitter rate error
has been detected. The transponder may recover
itself, but if it does not, restart the unit. If the
message returns after restarting, contact Appareo
for further assistance.