background image

 Getting started: choosing a location

 

Risk of fire: 

These units of passive RGB LED panels have been designed to work in dry indoor  
environments at environmental temperatures up to 105 degrees Fahrenheit.

 

Do not:

  Operate the units of passive RGB LED panels in environments with more than 105°F  

  environmental temperature or more than 80% humidity.

  Operate the units of passive RGB LED panels in any closed environment, 

  unless forced air convection is provided. 

  Operate less than 24” distance from any flammable surface. 

 Getting started: secure mounting

The units of passive RGB LED panels can be mounted in various ways:

Floor standing operation

  Turn the bracket to the lower side of the unit and fold out the second bracket.

  Place the unit in a secure position. 

  Use the provided cable slots in the bracket to route cables. 

  Make sure to comply with cooling requirements of the power supply. 

Hanging/Rigging, ceiling-mounted operation

 

Risk of injury: 

Overhead mounting requires extensive experience, including among others calculating working load limits, 
good knowledge of the installation material being used, and periodic safety inspection of all installation  
material and the unit.  If you lack such qualifications, do not attempt the installation yourself.  Improper  
installation can result in body injury.  Be sure to complete all rigging and installation procedures before  
applying power to the unit.

•  Leave the inner and outer bracket folded. 
•  The unit should be installed out of reach of people and areas where persons may walk or be seated. 
•  Make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
•  In fixed installations, attach the unit with self-locking screws/nuts to the mounting point. 
•  When mounting the unit to truss be sure to secure an appropriately rated clamp, available from Apollo,
   to the hanging yoke through the center hole of the hanging yoke. 
•  Attach the supplied M6 safety lug to the rear side thread insert rigging point and secure the installation  
  with an appropriate safety cable fixed to an individual separate mounting point.  Be sure to only  
  use the designated rigging point for the safety cable. 
•  Always use a certified safety cable that can hold 12 times the weight of the device when installing the  
  unit.  This secondary safety attachment should be installed in a way that no part of the installation can 
  drop more than 9”  if the main attachment fails.
•  Never stand directly below the device when mounting, removing, or servicing the fixture. 
•  The installations should be inspected every year by a skilled person to ensure safety.
•  Use the provided cable securing slots in the bracket to secure any cables using a cable tie.
•  Make sure to comply with cooling requirements of the power supply. 

“C” Color Mode

Press the MODE button (5) until the first digit on the display shows “C”, indicating operation in “color” mode. Choose a color by 
using the UP/DOWN buttons (6 or 7), see list below. 

Knob (1) determines the output level. 

Available color presets:

C 0

all off

C10

Blue Green

C 1

Red

C11

Lavender

C 2

Green

C12

Hot Pink

C 3

Blue

C13

Flesh

C 4

Yellow

C14

Light Blue Green

C 5

Pink

C15

Light Green

C 6

Turquoise

C16

Light Purple

C 7

Lime

C17

Light Lavender

C 8

Orange

C18

Light Blue

C 9

Marine

C19

White

“SLA” DMX Slave Mode

Press the MODE button (5) until the display shows “SLA”, indicating operation in “slave” mode. In this mode the unit is set to DMX-

channel 001 in order to receive the signals from a master 1012 unit being in mode “A“ or “C“. The knob(1) is disabled.

“D” DMX Mode 

Press the MODE button (5) until the display shows “D”, indicating operation in “d” (DMX) mode. Shortly after that, the display 

shows the DMX starting address. Set DMX address by using the UP/DOWN buttons (6 or 7).  

In this mode the knob (1) is disabled.

The unit requires 4 DMX channels.  

DMX channel

Value Range

Function

CH1 

000-255

Red level

CH2

000-255

Green level

CH3

000-255

Blue level

CH4

000-127

Master output level

128-227

Strobe (128=slow / 227=max. speed 23 Hz)

228-255

Master level full on, Strobe off