LIMITED TWO-YEAR WARRANTY

Apollo  Gate  Operators  are  warranted  against  defects  for  a  period  of

24  months  from  the  date  of  purchase,  providing  recommended  installation
procedures  are  followed.  This  warranty  is  in  lieu  of  all  other  warranties
expressed  or  implied  (some  states  do  not  allow  limitations  on  how  long  an
implied warranty lasts, so this limitation may not apply to you) and shall be
considered  void  if  damage  was  due  to  improper  installation  or  use,
connection  to  improper  power  source,  or  if  damage  was  caused  by  fire,
flood,  or  lightning.  The  manufacturer  will  not  be  responsible  for  any  labor
charges incurred in the removal or replacement of defective parts.

In case of failure due to defective material or workmanship during the

warranty  period,  the  defective  part  will  be  repaired  or  replaced  at  the
manufacturer’s option at no charge if returned freight prepaid. New or factory
rebuilt replacements may be used. Replacement parts are warranted for the
remaining portion of the original warranty period. The manufacturer will pay
standard  ground  freight  back  to  the  customer  on  the  return  of  repaired  or
replaced items in warranty.

Lighting  or  electrical  power  surges  may  cause  damage  beyond  repair  and
are not covered in this warranty.

APOLLO

Gate Operators, Inc.

Summary of Contents for METRODUALetl

Page 1: ...APOLLO Gate Operators Inc INSTALLATION MANUAL 06 09 METROETL METRODUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA A member of the NICE group...

Page 2: ...perator Installation 7 Gate and Control Box Installation 8 Limit Adjustments 9 Electrical Connections 10 Battery Connections 11 Encoder Board Connections 12 Dimensions and Options 13 Programming Curre...

Page 3: ...with operator controls Keep the remote con trol away from children Always keep people and objects away from the gate NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE ARM Test the operator monthly see...

Page 4: ...outages The battery may be recharged with a trickle charger or by solar energy eliminating the need for costly trenching to remote entrances If a trickle charger is used and a standard electrical outl...

Page 5: ...d If additional cable is required do not cut out the blocking diode when adding the cable 4 Is electricity available if required Consider safety and access options Recommend if needed 1 Will there be...

Page 6: ...ox lid c Motor d Limit switches 2 e Mechanical stop bracket f Ball g Release lever h Connecting lever i Control bracket j Hardware kit k Control box l Caution signs 2 m Cable n Battery charger optiona...

Page 7: ...7 METROETL...

Page 8: ...the motor Do not mount the control box where the person using the push button on side of the box can come in contact with the gate Use mounting hardware capable of supporting the weight of the contro...

Page 9: ...close limit switch with supplied screws so that switch is activated Move arm to open stop and install open limit switch with supplied screws so that switch is activated Mechanical Stop and Limit Switc...

Page 10: ...For right mounted operators blue motor wire goes to red cable wire brown motor wire to black cable wire To verify motor wiring place gate half way open plug main harness into emergency bypass for 2 s...

Page 11: ...battery is recommended with solar charging BAT12V33 12 Volt 34aH Sealed Battery Connect the two ring terminals on the con nector end of the cable to the battery The battery charger or solar panel sho...

Page 12: ...12 SIREN GND OPERATOR CABLE BLUE METRO Wiring Diagram YELLOW YELLOW RED BLACK...

Page 13: ...13 METROETL...

Page 14: ...edure See page 9 10 1 Press and hold the LED ENABLE button for five seconds and release The STOP LED will blink indicating that the board is in learn mode 3 Cycle gate arm for 3 4 full cycles The STOP...

Page 15: ...s Optional Device Input Remote Monitor Outputs Microprocessor Version 32 00 04 or higher must be used with Toona Timer To Close Dual Gate Delay Current Sensitivity Adjustments Program Switches 835 836...

Page 16: ...ximum travel or the 15 amp fuse will open Fuse should be checked before returning gate to service EMERGENCY BYPASS 12V Supplied battery voltage SLV Slave Operator Indicator indicates slave side of gat...

Page 17: ...to assist in installation and troubleshooting Hold the push button down for five seconds to put the board in program mode RESET Resets the microprocessor Returns processor to last known state Jumpers...

Page 18: ...eased 6 LOCK TYPE For 12V mechanical solenoid locks For 12V magnetic locks 12V for 4 seconds on open cycle 12V when on close limit 7 COAST ENABLE Gate will stop immediately when at Gate will coast min...

Page 19: ...ion see program switch 5 for options OPEN Open input from a 3 button station see program switch 5 for options GND Supplied Battery Ground GND Supplied Battery Ground FREE EXIT Opens gate if closed sto...

Page 20: ...or on the Remote Monitor Output Connector block Connect the black wire to the GND connector on the Remote Monitor Output Connector block Red Black Set Program Switch 4 as preferred ON Upon activation...

Page 21: ...itches to the same position Transmitters must match code switches for proper operation If power is taken directly from battery or connected as shown below receiver should be configured for 12VDC Multi...

Page 22: ...r Sealed Lead Acid Recommended Battery solar charged 12 V 105 aH Battery Charger 1 5 or 6 amp Automatic Recommended Solar Panel 5 watt minimum Duty Cycle 40 percent Operating Temperature 20 C 50 C Cur...

Page 23: ...lightning The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In case of failure due to defective material or workmanship during t...