6. Specifications
Pyranometer spectral response:
385 to 2105 nm (upward-looking)
295 to 2685 nm (downward-looking)
Pyranometer sensitivity range:
0.057 mV per W/m
2
(upward-looking)
0.15 mV per W/m
2
(downward-looking)
Pyranometer expected output range:
0 to 114 mV (upward-looking)
0 to 300 mV (downward-looking)
Pyrgeometer spectral response:
5,000 to 30,000 nm
Pyrgeometer sensitivity range:
0.12 mV per W/m
2
Pyrgeometer expected output range:
–24 to 24 mV
Operating temperature range:
–50 to 80 °C
Relative humidity:
0 to 100%
Response time:
1 s (SDI-12 data transfer rate; detector response times
are 0.5 s)
Heater current drain (at 12 VDC):
63 mA (heaters on; communication enabled)
1.5 mA (heaters off; communication enabled)
0.6 mA (heaters off; communication disabled)
Dimensions:
11.6 x 4.5 x 6.6 cm (4.6 x 1.8 x 2.6 in)
Weight:
320 g (11.29 oz) with mounting rod and 5 m (16.4 ft)
cable
Compliance:
View compliance documents at:
7. Installation
If you are programming your data logger with
Short Cut
, skip
(p. 6) and
Short Cut
does this work for you. See
(p. 1) for a tutorial.
7.1 Wiring to the data logger
Connect the SN500SS to the data logger in the order shown in
SN500SS Net Radiometer