INTRODUCTION 

All objects with a temperature above absolute zero emit electromagnetic radiation. The wavelengths and intensity 
of radiation emitted are related to the temperature of the object. The atmosphere and terrestrial surfaces (e.g., 
soil, plant canopies, water, snow) emit radiation in the mid infrared portion of the electromagnetic spectrum 
(approximately 4-50 µm). 

Pyrgeometers are sensors that measure the net longwave radiation difference between the detector surface and 
surface the detector is directed towards (typically, atmosphere or ground surface). Longwave radiation emitted by 
the surface of interest can be calculated with the additional measurement of detector temperature, typically 
accomplished via an internal thermistor or PRT. 

Typical applications of pyrgeometers include measurement of incoming longwave radiation from the sky and 
outgoing longwave radiation from terrestrial surfaces in atmospheric and energy balance studies. Incoming 
longwave radiation measurements from pyrgeometers are an important input to frost prediction models. 
Pyrgeometers are also integrated into net radiometers for measurement of net radiation at the land surface. 

Apogee Instruments SL-510 and SL-610 pyrgeometers consist of a thermopile detector, silicon filter with a 
diamond-like carbon coating (for weatherproofing), precision thermistor (for detector temperature measurement), 
heater, and signal processing circuitry mounted in an anodized aluminum housing, and a cable to connect the 
sensor to a measurement device. Sensors are potted solid with no internal air space and are designed for 
continuous measurement of longwave radiation from the sky and terrestrial surfaces in outdoor environments. SL-
510 and SL-610 pyrgeometers output an analog voltage that is directly proportional to the longwave radiation 
balance of the target (surface the detector is directed towards) and detector; the detector is sensitive to radiation 
incident on a planar surface (does not have to be horizontal), where the radiation emanates from all angles of a 
hemisphere. Longwave radiation incident on the detector is calculated from the radiation balance measurement 
and detector temperature measurement. 

Summary of Contents for SL-510

Page 1: ...NTS INC 721 WEST 1800 NORTH LOGAN UTAH 84321 USA TEL 435 792 4700 FAX 435 787 8268 WEB APOGEEINSTRUMENTS COM Copyright 2020 Apogee Instruments Inc OWNER S MANUAL PYRGEOMETER Models SL 510 and SL 610 R...

Page 2: ...e of Compliance 3 Introduction 4 Sensor Models 5 Specifications 6 Deployment and Installation 8 Cable Connectors 9 Operation and Measurement 10 Maintenance and Recalibration 15 Troubleshooting and Cus...

Page 3: ...lectrical and electronic products with respect to the restriction of hazardous substances Please be advised that based on the information available to us from our raw material suppliers the products m...

Page 4: ...om pyrgeometers are an important input to frost prediction models Pyrgeometers are also integrated into net radiometers for measurement of net radiation at the land surface Apogee Instruments SL 510 a...

Page 5: ...ing longwave radiation and SL 610 for terrestrial surface measurements downward looking sensor measures outgoing longwave radiation SL 510 Upward looking sensor Sensor model number and serial number a...

Page 6: ...power requirement at 12 V DC Dimensions 27 5 mm height 23 5 mm diameter Mass 90 g 100 g Cable 5 m of six conductor shielded twisted pair wire TPR jacket high water resistance high UV stability flexib...

Page 7: ...7...

Page 8: ...mounting on a cross arm an Apogee Instruments model AM 110 mounting bracket is recommended Sensors must be carefully mounted in order to view the desired target surface sky or ground and avoid includi...

Page 9: ...atalogger end of the cable If a replacement cable is ever needed please contact Apogee directly to ensure ordering the proper pigtail configuration Alignment When reconnecting the sensor arrows on the...

Page 10: ...ower source VERY IMPORTANT Apogee changed all wiring colors of our bare lead sensors in March 2018 in conjunction with the release of inline cable connectors on some sensors To ensure proper connectio...

Page 11: ...emperature are controlled independently At each calibration set point detectors are held at a constant temperature while the blackbody cone is controlled at temperatures below approximately 20 C for f...

Page 12: ...nt where an excitation voltage is input across the bridge resistor and an output voltage is measured across the thermistor Thermistor wiring for SL 510 Serial Number 1074 and above or with cable conne...

Page 13: ...4 B 2 21451 x 10 4 and C 1 26233 x 10 7 Longwave Radiation Measurement The detector output from SL 510 and SL 610 pyrgeometers follows the fundamental physics of the Stefan Boltzmann Law where radiat...

Page 14: ...st deposition The heater is designed to keep the water liquid and frozen off the silicon filter and does not need to be powered in order to make measurements of longwave radiation However if the filte...

Page 15: ...ts can be removed with a dilute acid e g vinegar Salt deposits cannot be removed with solvents such as alcohol or acetone 3 Dust and dirt deposition on the window usually a larger problem in windy env...

Page 16: ...fference between target and detector Thus a compatible measurement device e g datalogger or controller should have resolution of at least 0 11 mV to produce longwave radiation resolution of 1 W m 2 Me...

Page 17: ...ur factory The warranty does not cover equipment that has been damaged due to the following conditions 1 Improper installation or abuse 2 Operation of the instrument outside of its specified operating...

Page 18: ...manship Apogee Instruments will repair or replace the items free of charge If it is determined that your product is not covered under warranty you will be informed and given an estimated repair replac...

Reviews: